AMTROL ST-12 (Therm-X-Trol) is a water heater expansion tank, designed for use in domestic hot water heating systems to eliminate the potential hazards of water expansion. Water heater expansion tank is commonly installed in a domestic hot water system that contains a backflow preventer, a check valve or a pressure reducing valve. AMTROL ST-12 Applications: Residential water heaters, Laundromats, dormitories, office/apartment buildings, restaurants, etc.

  • Eliminates the waste of energy and water, thus saving money
  • Protects the water heater and plumbing fixtures from premature failure
  • Prevents a dangerous pressure build-up in the system
  • Prevents the relief valve from going off
  • Therm-X-Trol brand is the #1 choice of professional installers
  • A professional plumber should check the complete system, including the Therm-X-Trol, yearly and more frequently as the system ages
  • Click here to check out our buying guide on water heaters

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

14 Questions21 Answers

Customer Questions & Answers

Therm-X-Trol ST-12 Expansion Tank
Therm-X-Trol ST-12 Expansion Tank

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
This question is from Therm-X-Trol ST-12 Expansion Tank
 
3 answers

does it matter if this is installed with the air cap on the top and the screw in fitting on the bottom?

This question is from Therm-X-Trol ST-12 Expansion Tank
Asked by
Read all my Q&A
February 16, 2015
I have one of these that was installed 18 years ago with the air cap on the top and the cold water supply fitting on the bottom. (opposite of the product photo). Im just curious if it matters which orientation it goes.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
castle rock colorado
Read all my Q&A
March 14, 2016
Answer: 
Yes, it can matter. The idea of the tank is that expanded hot water in the system will cause water to push against the bladder for expansion, and the bladder will push it back, and thus the water will expand into the tank, and back out depending upon the water pressure, This in part aids in keeping the system operating at a stable pressure. If your bladder wears out and leaks, the tank will fill with Read More
Yes, it can matter. The idea of the tank is that expanded hot water in the system will cause water to push against the bladder for expansion, and the bladder will push it back, and thus the water will expand into the tank, and back out depending upon the water pressure, This in part aids in keeping the system operating at a stable pressure. If your bladder wears out and leaks, the tank will fill with water. If the tank is suspended with the air valve on the bottom, you will notice water flow out the air valve when you test it, and a tank hanging down from its fitting is probably a lot more stable when full of water than it would be if it were inverted. Some will argue that solids in the water may fall into the tank when it hangs down, and will not collect on the bladder when it is hanging with the air valve at the top. These solids have been argued to degrade a bladder. The st-12 comes with a device that is intended to prevent these solids from accumulating on the bladder. Read Less
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

Asked by
pa.
Read all my Q&A
October 6, 2015
Answer: 
does not matter !!!
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

February 20, 2015
Answer: 
The orientation of the unit is not relevant to its operation.
+3points
3out of 3found this answer helpful.
Was this helpful?helpful3unhelpful0
This question is from Therm-X-Trol ST-12 Expansion Tank
 
3 answers

is this st-12 expansion tank always filled with water, and how would you know if it is bad?

This question is from Therm-X-Trol ST-12 Expansion Tank
Asked by
Long Island, N Y
Read all my Q&A
September 26, 2014
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
Missouri
Read all my Q&A
February 4, 2015
Answer: 
I don't know if it is always filled with water or not. The pressure relief valve on my hot water heater was letting water flow out. A plumber friend suggested that it might be the expansion tank tied to the system. Seems the bladder in the tank will rupture after a while, in my case 16 years. Replaced the tank with same brand and model as originally installed, problem fixed.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Read all my Q&A
December 11, 2014
Answer: 
Should be if it's doing its job properly. The only way I knew mine was bad was it started leaking down the outside of it.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

Asked by
Colorado
Read all my Q&A
September 30, 2014
Answer: 
The rubber bladder does not contain water only air, which you preset to your domestic water pressure. The water surrounds the bladder and if it is bad you get what sounds like spurts of water or air out of a faucet. That's what mine was doing and after I put the new one on it quit that spurting.
-1point
0out of 1found this answer helpful.
Was this helpful?helpful0unhelpful1
This question is from Therm-X-Trol ST-12 Expansion Tank
 
2 answers

Sizing correctly

This question is from Therm-X-Trol ST-12 Expansion Tank
Asked by
Pittsburgh PA
Read all my Q&A
September 15, 2015
The incoming house pressure is 120 PSI. I will reduce to 60 PSI with a regulator. I'll be installing a brand new natural gas 40 gallon hot water heater. Would a 2 gallon expansion tank be sufficient or will I need to move to the 5 gallon unit?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
Seattle
Read all my Q&A
Home Improvement Profile: DIYer
September 30, 2015
Answer: 
ST-5 at 140 degrees avg
ST-8 at 160
Generally, I would go with the larger model as the expense is negligible. Amtrol has a sizing guide on their website.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Read all my Q&A
September 17, 2015
Answer: 
Great question. I think you will be fine with the smaller but I will put a link to the on line calculator below. Please keep in mind that the biggest error with thermal expansion tanks is that contractors think they are plug and play. You need to balance the tank to the house pressure during install. This may me mean adding or removing pressure from the side of the tank that has the gas. This is done by Read More
Great question. I think you will be fine with the smaller but I will put a link to the on line calculator below. Please keep in mind that the biggest error with thermal expansion tanks is that contractors think they are plug and play. You need to balance the tank to the house pressure during install. This may me mean adding or removing pressure from the side of the tank that has the gas. This is done by letting some of the nitrogen out at the schrader valve or pumping air in with a bicycle pump. Also keep in mind that pressure reducing valves have a limited life. Eventually water will leak by the stops and pressurize the down stream system. It will still work well when water is flowing but you will find that pressure builds when it is not. When this happens and the relief valve starts to burp periodically, don't assume the thermal tank is bad, it is more likely the reducing valve. For this reason it is always good to install a pressure gauge on the down stream sized. Install it with a ball valve protecting it. This will allow you to take pressure reading and then shut off the pressure to the gauge. http://www.amtrol.com/support/therm_res_sizing.html Read Less
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0
This question is from Therm-X-Trol ST-12 Expansion Tank
 
2 answers

if i tap on my expansion tank it sounds like it is full of concrete. does this mean its bad

This question is from Therm-X-Trol ST-12 Expansion Tank
Asked by
new york
Read all my Q&A
March 4, 2015
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
pa.
Read all my Q&A
October 6, 2015
Answer: 
yes ... the bladder inside is torn and water has filled the cavity where air should be
+3points
3out of 3found this answer helpful.
Was this helpful?helpful3unhelpful0

Asked by
Read all my Q&A
March 17, 2015
Answer: 
Thermal expansion tanks need to be calibrated when installed but many contractors forget or don't know they need to do this. So it could be completely filled with water because it is bad or was not set up properly. I would start by pushing on the schrader valve, AKA the bike tire air valve looking thing at the bottom. If water comes out you know the diaphragm has ripped and the unit is dead. If air comes Read More
Thermal expansion tanks need to be calibrated when installed but many contractors forget or don't know they need to do this. So it could be completely filled with water because it is bad or was not set up properly. I would start by pushing on the schrader valve, AKA the bike tire air valve looking thing at the bottom. If water comes out you know the diaphragm has ripped and the unit is dead. If air comes out you know it is still good. Then you need to check the pressure and calibrate it to the water pressure in your house, by letting air in or out. Directions are on the Amtrol web site. Please note this is a expansion tank for a hot water heater, expansion tanks for boilers or forced hot water heating systems are different. If you have further questions please feel free to call
chris 1 800 445 5816
Read Less
+4points
4out of 4found this answer helpful.
Was this helpful?helpful4unhelpful0
2 »
  • 2016-08-29 T15:57:22.362-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_204296372, prod, sort_default
2 »
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 254ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 4.6 out of 5 by 17 reviewers.
Rated 5.0 out of 5.0 by Does What it is supposed to! City installed new water meters with a check valve in the system. Old system did not have check valve. Since the new water meter was put in my water heater started to relieve thermal caused pressure through the safety valve. Always water in the bucket as our basement has no drains. Our city water pressure was 70 PSI. Matched the tank pressure to this, installed the tank, and the water heater safety valve has not released any water due to pressure. Good value and easy to install. April 18, 2014
Rated 5.0 out of 5.0 by Easy install and directions are great! The thermal expansion tank was very easy to install as were the directions to follow. The thermal expansion tank was a replacement for a unit which was worn out. The tank was a near identical replacement for the exixting unit. I would highly recommend this product if you have a hot water heater that has a back flow preventor installed somewhere in line to allow the water to expand. Othewise you may create a situtation where the pipes may burst due to over pressure. December 10, 2013
Rated 5.0 out of 5.0 by Works as advertised After installing a solar hot water system that utilizes a 120 gallon tank, I started having elevated water pressure (at times) in the house. I was also getting pipe "hammering," and was afraid I'd end up with a broken pipe. My previous hot water heater was a 50 gallon unit which must have had the same issues, but to a much lesser extent. I never noticed the problem until the larger tank was installed. The Amtrol thermal expansion tank seems to have solved the problems. It's been in for about two weeks now, and haven't had a single high pressure episode, or any pipe hammering since. The unit appears to be of very high quality, and I had no problems installing it...very simple. I ended up making my own mounting bracket for the unit. There are commercially available brackets made, but the Home Depot did not carry them, or offer them on their website. To save the cost + shipping from the other suppliers, I built a simple unit out of plywood, and a couple of large hose clamps. January 11, 2014
Rated 5.0 out of 5.0 by Therm-x-Trol ST-12 Expansion Tank This is a great expansion tank, took care of my potable water pipe shutter January 6, 2016
Rated 5.0 out of 5.0 by Great product and service Great product great customer service from manufacturer January 5, 2016
Rated 5.0 out of 5.0 by Therm-x-trol Easy to install ... decent price ... exact fit as my old one . Good Product October 6, 2015
Rated 5.0 out of 5.0 by Direct replacement Exactly what I ordered, direct replacement, same brand and model as originally installed. February 4, 2015
Rated 5.0 out of 5.0 by Great product! Replaced 8 yr old original This item came with my house upon its construction. That was 8 years ago. Recently, it started leaking down the side (corroded around seam). It was time to buy a new one. Looked no further than here at Home Depot, purchased same item, great price, fast shipping. If needed, will buy again in the future. December 11, 2014