Cadet Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White
0027418728029

Cadet

Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White

  • Twist dial is easy to adjust
  • Snap-action, bi-metal temperature control
  • Color-coded wires help assure easy installation
$21.45 /each

Frequently Bought Together

Product Overview

This Cadet Double-Pole, Wall-Mount non-programmable Thermostat is designed for use with 120/208/240-volt baseboard and fan-forced heaters to control your room temperature. It offers a temperature range of 40 degrees F - 80 degrees F and is line voltage control with a maximum load of 22 amps. An economical choice for electric resistance heating, it offers a 4-wire connection with color-coded wires to help ensure easy installation.

  • Non-programmable. For use with 120/208/240-volt electric baseboard and fan-forced heaters
  • Twist dial is easy to read and adjust
  • 40 degrees F - 80 degrees F temperature range
  • Comfort range: 3 to 6 degrees
  • Snap-action, bi-metal temperature control with positive off setting
  • Color-coded wires help assure easy installation
  • 22 amp, double-pole, 4-wire design
  • White
  • How to choose the right thermostat for your home

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Compare Similar

Price
$15.98 /each
$21.45 /each
$21.48 /each
$26.98 /each
Name Single-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White Single-Pole Electric Baseboard-Mount Mechanical Thermostat in White Round Mechanical Thermostat Heat Only
Brand Cadet Cadet Cadet Honeywell
Ratings (40) (60) (30) (93)
Thermostat Type Heat Only Heat Only Heat Only Heat Only
Operation Type Mechanical Mechanical Mechanical Mechanical
Features No Additional Features No Additional Features No Additional Features
Certifications and Listings 1-UL Listed,CSA Listed 1-UL Listed,CSA Listed 1-UL Listed No Certifications or Listings
View Product View Product View Product View Product

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

37 Questions56 Answers

Customer Questions & Answers

Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White
Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
3 answers

where do I attach the ground wire to the thermostat?

This question is from Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White
Asked by
R.I.
Read all my Q&A
December 21, 2013
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
New Hampshire, USA
Read all my Q&A
March 11, 2014
Answer: 
There is no attachment for ground ON the thermostat. Attach the grounds together from the wires and you are all set
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Burleson,TX
Read all my Q&A
March 11, 2014
Answer: 
You might think about getting a sparky to give you a hand here-- The thermostat is connected in the hot lead-- You need not worry about any thing else simply break the hot lead wire---------------wire in the thermostat and you are thru
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Vancouver, WA
Read all my Q&A
Home Improvement Profile: Professional
December 26, 2013
Answer: 
The T410 thermostat uses a plastic backing plate, so there no ground connection supplied or needed to install.
However, just a reminder that the heater itself should be grounded for safety, (bypassing the thermostat).
We hope that answers your question.
+3points
3out of 3found this answer helpful.
Was this helpful?helpful3unhelpful0
 
3 answers

How big of a hole do I need to cut in the wall?

This question is from Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White
Asked by
Read all my Q&A
December 3, 2013
Does this sit in a regular 1 gang box, or does it have a back that is not pictured?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
New Hampshire, USA
Read all my Q&A
March 11, 2014
Answer: 
Yes it will sit just fine in a one gang box, although if you put it in a deep well box it installs easier
+2points
2out of 2found this answer helpful.
Was this helpful?helpful2unhelpful0

Asked by
Burleson,TX
Read all my Q&A
March 11, 2014
Answer: 
Take the Thermostat to Home Depot They will get you the proper box and even go so far as to show you how to use a saw to cut the hole--nice folks
0points
1out of 2found this answer helpful.
Was this helpful?helpful1unhelpful1

Asked by
Vancouver, WA
Read all my Q&A
Home Improvement Profile: Professional
December 3, 2013
Answer: 
The hole size should be 2 3/4 inches wide x 4 1/2 inches tall for the single gang box. The thermostat will need to be connected to the gang box and all line voltage connections should be made in the gang box per electrical code.
+3points
3out of 3found this answer helpful.
Was this helpful?helpful3unhelpful0
 
3 answers

Are thermostats wired only to the baseboard heaters, or is it 1 wire from the thermostat to the heater & 1 wire from the thermostat to the breaker box

This question is from Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White
Asked by
house
August 8, 2013
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
Indiana
Read all my Q&A
Home Improvement Profile: DIYer
December 29, 2015
Answer: 
I followed the Cadet Support User post and blew a breaker because it was incorrect advice. Really??? How frustrating. The instructions could be made so simple by stating which sets of wires are to the panel, and which wires are to the heater. Instead you get L1, L2, T1, T2, etc. just say Power1 (120), Power2 (240), Heater1 (120), Heater2 (240). Ughhh
-3points
2out of 7found this answer helpful.
Was this helpful?helpful2unhelpful5

Asked by
NY
Read all my Q&A
August 22, 2013
Answer: 
This thermostat comes with 4 wires. Top 2 wires (black and white) go to your power,and bottom two wires(black and white) go to your heater. The power will go through this termostat, and it will circulate the power to your heater. A typical 2 poles thermostat, the ability to turn your heater off. It works for both 120V or 220V heater. No possible way to control 2 heaters in different circut breaker. You Read More
This thermostat comes with 4 wires. Top 2 wires (black and white) go to your power,and bottom two wires(black and white) go to your heater. The power will go through this termostat, and it will circulate the power to your heater. A typical 2 poles thermostat, the ability to turn your heater off. It works for both 120V or 220V heater. No possible way to control 2 heaters in different circut breaker. You can only daisy chain your heater from one to the other,in order to control 2 heaters. Typical 120V circut breaker is designed to be 20 amps, because the wiring used is thinner than a 220V. Daisy chain your 120V heaters will trip your 20 amps circuit breaker. Read Less
+2points
2out of 2found this answer helpful.
Was this helpful?helpful2unhelpful0

Asked by
Vancouver, WA
Read all my Q&A
August 9, 2013
Answer: 
This depends on the voltage of the supply line. If you are running 240 volts (4 wires), the 2 red thermostat wires will connect to the "hot" supply wires and the 2 black thermostat wires will connect to the heater. If you are running 120 volts (2 wires) the 1 red thermostat wire will connect to one "hot" supply wire and 1 black thermostat wires will connect to the heater. Please see the installation Read More
This depends on the voltage of the supply line. If you are running 240 volts (4 wires), the 2 red thermostat wires will connect to the "hot" supply wires and the 2 black thermostat wires will connect to the heater. If you are running 120 volts (2 wires) the 1 red thermostat wire will connect to one "hot" supply wire and 1 black thermostat wires will connect to the heater. Please see the installation guide for this product on homedepot.com here: http://www.homedepot.com/catalog/pdfImages/50/50241949-25f7-428f-87cb-914b95bdea8b.pdf
Thanks Read Less
-3points
2out of 7found this answer helpful.
Was this helpful?helpful2unhelpful5
 
3 answers

Calibrate thermostat

This question is from Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White
Asked by
Ken
Round hill, va.
November 24, 2012
Room. Temp. 70degrees. Thermostat still on at 60
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
NY
Read all my Q&A
August 22, 2013
Answer: 
The location of your thermo stat is very important, so it is hard to be precise. You already know 10 degrees difference,so it much easier to adjust your temp. This is the main reason that many thermo stat don't come with a temp. degree,but rather a min to max dial.
0points
1out of 2found this answer helpful.
Was this helpful?helpful1unhelpful1

Asked by
derong
vernon ct
August 12, 2013
Answer: 
can you set and lock temperature.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Vancouver, WA
Read all my Q&A
November 26, 2012
Answer: 
Hi Ken and thank you for the question!
This particular thermostat, the T410 Double-Pole Mechanical series, cannot be calibrated. There are, however, electronic wall thermostats that offer increased temperature sensing capabilities, and energy savings. We have included a couple of the double-pole options as related items. Either one should work for your situation as a replacement thermostat. Their Read More
Hi Ken and thank you for the question!
This particular thermostat, the T410 Double-Pole Mechanical series, cannot be calibrated. There are, however, electronic wall thermostats that offer increased temperature sensing capabilities, and energy savings. We have included a couple of the double-pole options as related items. Either one should work for your situation as a replacement thermostat. Their maximum amperage load is 16 amps.
Thank you again for asking. Read Less
+1point
2out of 3found this answer helpful.
Was this helpful?helpful2unhelpful1
2 3 »
  • 2016-10-30 T22:39:55.515-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_202502063, prod, sort_default
2 3 »
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 77ms
  • QUESTIONS, PRODUCT

Customer Reviews

Double-Pole 22 Amp 120/240-Volt Wall-Mount Mechanical Non-programmable Thermostat in White is rated 3.7 out of 5 by 60.
Rated 2 out of 5 by from It did not meet my expectation as I had the mistaken expectation that it could be used to control... It did not meet my expectation as I had the mistaken expectation that it could be used to control something in the cooling mode.
Date published: 2016-11-15
Rated 5 out of 5 by from Works great with the Dimplex wall/ceiling mount heater I had installed in my garage. My electrici... Works great with the Dimplex wall/ceiling mount heater I had installed in my garage. My electrician bypassed the built in thermostat and mounted the Cadet thermostat in line on the wall below the unit so it was more accessible.
Date published: 2016-10-25
Rated 1 out of 5 by from The on-off temperature range is so wide as to make the thermostat unusable for many/most applicat... The on-off temperature range is so wide as to make the thermostat unusable for many/most applications. In actual use I have found it to exceed 10 degrees; hardly worth calling temperature control.
Date published: 2017-01-03
Rated 4 out of 5 by from Works well with built in bench seat heater. Somewhat bulky because of being wire direct. Works well with built in bench seat heater. Somewhat bulky because of being wire direct.
Date published: 2017-01-03
Rated 5 out of 5 by from Simple and to the point. Works great. Good price. Happy with the purchase. Simple and to the point. Works great. Good price. Happy with the purchase.
Date published: 2016-12-21
Rated 5 out of 5 by from THIS UNIT IS A SPARE ONE FOR THE HOUSE, IT NOT INSTALLED YET,. THIS UNIT IS A SPARE ONE FOR THE HOUSE, IT NOT INSTALLED YET,.
Date published: 2016-12-14
Rated 5 out of 5 by from Worked as Advertized Worked as Advertized
Date published: 2017-01-17
Rated 5 out of 5 by from GREAT PURCHASE This thermostat worked perfectly to replace a thermostat that was used for radiant ceiling heat in my mother's home. The size was not the same as the previous thermostat, and we inexpensively used a regular switch plate for a backing. Worked great! Quick shipping!
Date published: 2013-03-19
  • y_2017, m_1, d_20, h_13
  • bvseo_bulk, prod_bvrr, vn_bulk_0.0
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_60
  • loc_, sid_202502063, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 65ms
  • REVIEWS, PRODUCT