2 ft. In-Line GFCI Cord

$26.87 /each

Frequently Bought Together

Product Overview

The 2 ft. In-Line GFCI is ideal for indoor and outdoor use. It features built in GFCI protection against hazardous shock from damaged cords or exposure to water. A convenient heavy duty 2 foot, 12-Gauge cord with 3 outlet triple tap extends protection to wherever is needed.

California residents: see   Proposition 65 information

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

2 Questions1 Answer

Customer Questions & Answers

2 ft. In-Line GFCI Cord
2 ft. In-Line GFCI Cord

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
A review elsewhere said "What good is a GFCI plug if it resets when ever the power goes out? We had some short power outages and discovered that the plug goes into reset mode any time that occurs. It doesn't require a surge or power fault. If you unplug it you'll hear it click as it goes into reset mode. Or if you test it by using a power strip to turn off power (ensuring that power is cleanly terminated) you'll see the same behavior. So, if you have something important on this (like a sump or ejector pump) you could be in for a big surprise."
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answer (1)

Asked by
Read all my Q&A
December 7, 2015
Answer: 
Yes, this device is designed to reset automaticaly after power is restored without user assistance as noted at the end of product description. I've bought multiple quantities of this unit and couldn't be more happier with the auto reset feature. There are same units that are manual reset, so pay attention to product description.
+3points
3out of 3found this answer helpful.
Was this helpful?helpful3unhelpful0
This question is from 2 ft. In-Line GFCI Cord
 
0 answers

Can I plug a cord with a GFCI on it into this as an extension? I have a pool pump with a GFCI on the end and need 1'more

This question is from 2 ft. In-Line GFCI Cord
Asked by
Read all my Q&A
July 6, 2016
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
1 of 1
  • 2016-08-27 T16:05:58.281-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_203741466, prod, sort_default
1 of 1
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 21ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 4.0 out of 5 by 1 reviewer.
Rated 4.0 out of 5.0 by Excellent for GFCI cord replacement I broke the GFCI plug on my electric powerwasher so I bought this one with the intent of MacGyvering the cord onto the GFCI. It turns out I didn't need to. It's not in the description or in the instructions, but the three-outlet output cord is connected to the device via screw clamps in a dedicated compartment in the GFCI. This allowed me to simply cut my cord, strip the wires, and attach to the screw terminals. The compartment is accessed by removing the lower four screws on the back of the device , and it is watertight via a silicone gasket and rubber grommet for the cord. The cord is held in place by a strain-relief clamp and is screwed down so it doesn't pull out. There is even a strip gauge embossed on the side of the device to indicate how much wire to strip. I attached my cord and was up and running in 15 minutes. I haven't used this long-term, but so far I like the design. If you are looking to replace the GFCI on any outdoor electric advice, this is the cord to use. June 6, 2014
  • 2016-08-26 T14:43:41.841-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_1, tr_1
  • loc_en_US, sid_203741466, prod, sort_default
1-1 of 1
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 15ms
  • REVIEWS, PRODUCT