Model # BR4050B200V5

Internet #203026371

Store SKU #197300

Eaton 200 Amp 40-Space 50-Circuit Type-BR Main Breaker Load Center Value Pack Includes 4 Breakers
0786685478555

Eaton

200 Amp 40-Space 50-Circuit Type-BR Main Breaker Load Center Value Pack Includes 4 Breakers

  • Commercial grade Main Breaker
  • Steel backpan for reliable breaker mounting
  • Twin neutral bars for ease of installation
$135.00 /each

Frequently Bought Together

Product Overview

Specially designed for easy installation, Eaton's BR load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. The panels serve as main breaker for service entrances. The main breaker protects the main entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. The BR4050B200V5 is a 200 amp main breaker with 40 spaces and 50 circuits. It is a value pack for the cost conscious home owner or contractor. The value pack consists of the load center (and cover) plus 3-1P 20A, 1-30A 2P circuit breakers.

  • Amperage rating: 200A
  • Bus material: aluminum
  • Rated NEMA 1 for indoor use
  • Feed type: bottom or top which allows for straight-in wiring that saves labor and material
  • Interrupt rating: 25 kAIC
  • Mounting: combination
  • Number of circuits: 50
  • Number of spaces: 40
  • Phase: singel-phase
  • “Tangential” center knockout easier installation for conduit applications
  • 2/0 lug easily removable and can be installed in any location on the neutral bar
  • Neutral bus (Strap) is easily removable for sub-panel applications
  • Bonding Z-strap provides easy field conversion for service entrance applications
  • Twin neutral bars minimum 150% neutral capacity
  • Steel back pan provides solid and reliable breaker mounting-single piece design for stability and durability
  • Single keyhole mounting -one keyhole at the top and bottom provides easier mounting and leveling
  • Includes: 3-BR120s, 1-BR230 circuit breakers
  • Used with: type BR breakers
  • Learn More About Electrical Panels Here in our Buying Guide.



Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

Is the 200 AMP main breaker included?

Asked by: tsimpson
A trio of single-pole 20 amp breakers and 1 double-pole 30 amp breaker accompanied this load center for quick setup after installation.
Answered by: CommunityAnswer
Date published: 2017-04-05

Will older Bryant Circuit breakers work with this box?

I want to swap out my old Bryant breaker box with this box. Will my old Bryant circuit breakers work in this box? I would like to move my old breakers and add new ones as needed.
Asked by: Dee
  • y_2017, m_4, d_22, h_24CST
  • bvseo_bulk, prod_bvqa, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_, sid_203026371, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 16ms
  • QUESTIONS, PRODUCT

Customer Reviews

200 Amp 40-Space 50-Circuit Type-BR Main Breaker Load Center Value Pack Includes 4 Breakers is rated 5.0 out of 5 by 3.
Rated 5 out of 5 by from Eaton 200 Amp 4 spaces Really like this and More than enough space to separate everything and put on its own line vs overloading.
Date published: 2016-11-02
Rated 5 out of 5 by from Great panel with lots of space. I had the 30/40 main lug only version of this panel and wanted to install an interlock kit. You need a main breaker for that. My panel was already full and I also wanted room to expand. My electrician was able to replace it and install the interlock in about 4 hours. Even though this panel was much bigger in size than my old panel it sort of fit in since many of the holes were in the same place.
Date published: 2014-06-24
Rated 5 out of 5 by from Great Value This is a great value for the money. For only $124.00 I got 50 circuits, which is perfect for my house with electric appliances and a back up generator. And, it is Made in the USA.
Date published: 2014-05-08
  • y_2017, m_4, d_22, h_2
  • bvseo_bulk, prod_bvrr, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_, sid_203026371, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 17ms
  • REVIEWS, PRODUCT