Product Overview

The upgraded 10kW Home Generator System by GE now features Symphony II Power Management System allowing you to efficiently manage the energy demands of your whole house including up to two central air conditioners. Its advanced power controls keep more than just the essentials powered.The compact design is comparable in size to a standard central air unit and blends in beautifully with your home’s exterior and landscaping.Give yourself and your family the peace of mind that comes with knowing that if the power goes out, everything will still be on.

  • 10,000-Watt (LP) or 9,000-Watt (NG) generator best for small to medium sized homes with up to two 3-ton air conditioners
  • Power more for less with Symphony II power controls that manage high power demand appliances keeping more than just the essentials on
  • 4 year limited parts and labor warranty - one of the best comprehensive parts and labor warranties
  • Automatically starts when there is a power outage and shuts down when utility power is restored
  • Compact profile blends in with your home and landscaping much like your central air conditioning unit
  • Corrosion, chip and abrasion resistant enclosure for all-season protection
  • Powerful, performance driven Briggs and Stratton commercial-grade Vanguard V-twin engine for reliable operation
  • 100 amp Symphony II transfer switch monitors your home's connection to utility power and can be placed inside or outside the home (NEMA 3R)
  • Battery is sold separately, recommended batteries include: Werker brand (WKA12-35C), storage battery systems SBS (S-12330), battery specifications for 33 Amp hour are 12 volt DC, 350 cold cranking amps per minute, AGM (Absorbed Glass Mat) battery, requires two (2) installer-supplied M6 flat washers, contact batteries plus at 1-800-677-8278, option 2 for online sales, or other battery sales coutlets
  • Package includes: whole house symphony II switch, hour meter, battery charger, installation pad and synthetic oil

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Product Depth (in.) 
32 
Product Height (in.) 
38.5 
Product Length (in.) 
32 
Product Width (in.) 
34.25 

Details

Color Family 
Gray 
Commercial / Residential 
Residential 
Continuous Wattage 
10000 
Engine Displacement (cc) 
570 
Engine manufacturer 
Vanguard Commercial-Grade 
Generator Features 
Low Oil Shutdown,Hour Meter,Overload Protection 
Operational volume (dB) 
68 
Product Weight (lb.) 
299 lb 
Remote Monitoring 
Sold Separately 
Response time (sec.) 
30 
Returnable 
Non-Returnable 
UL Listing 
1-UL Listed 

Warranty / Certifications

Certifications and Listings 
CSA Listed,1-UL Listed 
ENERGY STAR Certified 
No 
Manufacturer Warranty 
4 Year Limited Parts and Labor 

More Products With These Features

Search

Customer Questions & Answers

3 Questions9 Answers

Customer Questions & Answers

10,000-Watt Home Generator System-DISCONTINUED
10,000-Watt Home Generator System-DISCONTINUED

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
3 answers

Can this unit be set up to operate without any electric supply? I'm desperate for lighting in a barn and have no electric supply.

This question is from 10,000-Watt Home Generator System-DISCONTINUED
Asked by
sammy
burgettstown
October 10, 2012
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
cincinnati
Read all my Q&A
January 4, 2014
Answer: 
I would not try to, they are really setup to run during power outages and not continous
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Read all my Q&A
November 27, 2012
Answer: 
Yes. A 12 volt battery and a gas supply is all that is needed to start & run the unit. If there is the necessity to keep the battery and oil warm in cold weather when the unit is not in use, you will need a 240 VAC supply.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Atlanta, GA
Read all my Q&A
October 17, 2012
Answer: 
Hi Sammy,
Thank you for your question.
Setting up this generator without an electric supply would void the warranty.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
3 answers

Can this generator be set up to run on natural gas?

This question is from 10,000-Watt Home Generator System-DISCONTINUED
Asked by
Art
San Antonio, Tx
July 9, 2012
Can this generator be set up to run on natural gas and other alternate fuel?
+1point
1out of 1found this question helpful.
Was this helpful?helpful1unhelpful0

Answers (3)

Asked by
cincinnati
Read all my Q&A
January 4, 2014
Answer: 
Mine has a connector that allows for natural gas or lp, very easy
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Read all my Q&A
November 27, 2012
Answer: 
No. It runs on either natural gas OR propane.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

July 10, 2012
Answer: 
Hello Art and thank you for your question.
The engine of your home generator system is factory calibrated to run on natural gas (NG). It may also be operated on liquefied petroleum (LP) vapor. The LP Conversion Kit is supplied and required to convert the unit to LP vapor fuel. The Operators Manual will include detailed instructions on selecting the fuel for your generator.
Best wishes on your project.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
3 answers

What is the fuel consumption on LP Gas /Hr?

This question is from 10,000-Watt Home Generator System-DISCONTINUED
Asked by
Steve
Meadville, PA
July 1, 2012
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
cincinnati
Read all my Q&A
January 4, 2014
Answer: 
approx. 1/2 gal per hour, depending on load
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Read all my Q&A
November 27, 2012
Answer: 
Straight from the Owner's Manual using LP Vapor,
35 cubic feet per hour at 1/2 load
65 cubic feet per hour at full load
Using natural gas,
84 cubic feet per hour at 1/2 load
162 cubic feet per hour at full load
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Atlanta, GA
Read all my Q&A
July 10, 2012
Answer: 
Hi Steve,
Thank you for your question.
The fuel consumption on this mode is at .96 Gallons per hour at half load and 1.82 gallons per hour at full load.
Hope this information helps.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
1 of 1
  • 2016-07-22 T15:05:24.459-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_203086868, prod, sort_default
1 of 1
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 155ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 2.5 out of 5 by 2 reviewers.
Rated 1.0 out of 5.0 by Failure for GE only 36 hours of run time (exercise time) and iy has failed, repair wants $80 hour and mileage starting as soon as he walks out his door. No GE generator product gets my recommendation.. January 4, 2014
Rated 4.0 out of 5.0 by This product is a good all in one package. The installation manual is comprehensive, if you are a do-it-yourselfer. If you are wondering how loud 70 db's is, it is LOUD; as loud as a push lawn mower. HomeDepot show's 68 db's in it's specs but the owners manual that comes with the unit rates it at 70 db's. Knowing this would not stop me from purchasing the generator but it is a good reference for those who are wondering. The package arrived in good shape and there were no missing items. I thought the battery charger was a seperate item but I called customer support and later received an email stating that it is incorporated into the unit. There was also two remote modules included. This was a bonus I did not expect! I did not buy this unit for the "automatic on" feature. I only want to run it while I am at home. Also, I did not connect my utility power lines to the transfer switch. If the power goes out, I will have to plug the generater feed into my distribution box. This is done by wiring the generator feed lines from the transfer switch to a receptacle and then using a plug & cable assembly to backfeed into my distribution box. I did use a seperate 2 pole circuitbreaker to feed power to the transferswitch to permit the use of the battery warmer, oil warmer and allow communications between the transfer switch and the generator. The battery warmer and oil warmer are easy to install and the electrical connections for them could not be more simple. The unit looks nice and appears to be well constructed. Although the 4 year or 1600 hours warrenty sounds good if power outages are rare in your area, when you factor in 20 minutes a week for the "self test" feature those 1600 hours could disappear quickly if you have prolonged outages on a regular basis. I have no "buyers remorse". Only time will show if the quality of the product equals the cost of the purchase and installation. November 27, 2012
  • 2016-07-27 T01:14:54.952-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_2, tr_2
  • loc_en_US, sid_203086868, prod, sort_default
1-2 of 2
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 136ms
  • REVIEWS, PRODUCT