Model # TM3215CCU1K

Internet #100193092

Store SKU #743334

GE PowerMark Gold 150 Amp 32-Space 32-Circuit Indoor Main Breaker Value Kit Includes Select Circuit Breaker
0043481001104

GE

PowerMark Gold 150 Amp 32-Space 32-Circuit Indoor Main Breaker Value Kit Includes Select Circuit Breaker

$125.00 /each

Frequently Bought Together

Product Overview

This value kit includes 6 20 Amp Single-Pole, 1 30 Amp Double-Pole, 1 50 Amp Double-Pole THQL 1 in. Circuit Breakers. The load center includes a sturdy tin-plated copper buss bar and a galvanized box for increased durability and reliability. The one-piece interior removes and re-installs easily. Indoor NEMA 1 enclosure with combination surface/flush front. This load center is UL listed and ANSI Certified.

  • Rust-resistant galvanized box
  • Highly conductive copper buss bar
  • Factory-installed main breaker, full-length neutral bars, top or bottom feed and self-adjusting, dead-front cover
  • 100% rated split neutral on each side
  • Single phase, 3-wire, 120/240-Volt and 22K AIC rating
  • All neutral holes are rated for 14 - 4 wire
  • Accepts GE, GFCI and AFCI circuit breakers
  • UL listed and ANSI certified
  • Includes 6 THQL1120 single-pole 20 Amp circuit breakers, 1 THQL2130 2-pole 30 Amp circuit breaker and 1 THQL2150 2-pole 50 Amp circuit breaker
  • Learn More About Electrical Panels Here in our Buying Guide.
  • Click here for more information on Electronic Recycling Programs

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

6 Questions8 Answers

Customer Questions & Answers

PowerMark Gold 150 Amp 32-Space 32-Circuit Indoor Main Breaker Value Kit Includes Select Circuit Breaker
PowerMark Gold 150 Amp 32-Space 32-Circuit Indoor Main Breaker Value Kit Includes Select Circuit Breaker

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
2 answers

IS THE 150A MAIN BREAKER INCLUDED OR DO I HAVE TO BUY ONE FOR THE MODEL TM3215CCU1K

This question is from PowerMark Gold 150 Amp 32-Space 32-Circuit Indoor Main Breaker Value Kit Includes Select Circuit Breaker
Asked by
FL
Read all my Q&A
September 6, 2014
PICTURE NOT VERY DEFINITIVE
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
Northern Virginia
Read all my Q&A
May 19, 2015
Answer: 
Breaker comes installed along with the rest of the panel interior.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

September 12, 2014
Answer: 
Dear Valued Home Depot Customer,
We reached out to the MFG for more information and find their response below.
"Main breaker is included."
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
2 answers

where are the breaker panels made?

This question is from PowerMark Gold 150 Amp 32-Space 32-Circuit Indoor Main Breaker Value Kit Includes Select Circuit Breaker
Asked by
Globe az
Read all my Q&A
April 7, 2014
Model # 2020ccupl2
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
Northern Virginia
Read all my Q&A
May 19, 2015
Answer: 
Shockingly enough the panel I received was made in USA. Not sure about the breakers.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

April 21, 2014
Answer: 
Dear Mick,
We reached out to the MFG with your question and below is their response.
"This unit is made in Morristown, TN"
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
2 answers

How big a wire size will the main breaker lugs accommodate? 3/0, 4/0??

This question is from PowerMark Gold 150 Amp 32-Space 32-Circuit Indoor Main Breaker Value Kit Includes Select Circuit Breaker
Asked by
Robert
July 6, 2011
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
Northern Virginia
Read all my Q&A
May 19, 2015
Answer: 
I installed one last week. I believe it said 3/0 was the maximum.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Atlanta, GA
Read all my Q&A
July 20, 2011
Answer: 
Hey Robert,
This is Gregg from the How-To Community, http://community.homedepot.com
The main breaker lugs can fit up to 3/0 wire size.
Gregg
-1point
0out of 1found this answer helpful.
Was this helpful?helpful0unhelpful1
 
1 answer

Is this a surface or flush mount panel?

This question is from PowerMark Gold 150 Amp 32-Space 32-Circuit Indoor Main Breaker Value Kit Includes Select Circuit Breaker
Asked by
atlanta ga
Read all my Q&A
June 28, 2016
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answer (1)

June 28, 2016
Answer: 
This is an indoor NEMA 1 enclosure with combination surface/flush front.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
2 »
  • 2016-10-30 T22:31:29.434-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_100193092, prod, sort_default
2 »
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 199ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 4.3 out of 5 by 7 reviewers.
Rated 5.0 out of 5.0 by great value- This is the perfect panel for a service change or new job. I saved $50.00 with this bargain. My local supplier had it, but it was more expensive and the main breaker had to be purchased separate. September 15, 2015
Rated 5.0 out of 5.0 by Great power pannel Great pannel. Good job helping me locate wheir it was and when it WOuld arrive. September 15, 2015
Rated 4.0 out of 5.0 by Good Product Decent quality, installer-friendly panel at a reasonable price. Breakers are a little wiggly on the non-bus end after being installed. Twist-outs in the cover could be cut a little more precisely. Note: Although panel will accept some skinny breakers, it is only rated for 32 total circuits. May 19, 2015
Rated 5.0 out of 5.0 by Great replacement panel I needed a ge replacement panel and this one worked great January 27, 2015
Rated 4.0 out of 5.0 by I've recently purchased three of these load centers. I am a contractor and thid is my load center of choice for residential sub panels. I like the layout inside--something that would be great if we could see on this website--the copper buss; the amount of breaker spaces; the room inside for routing wires and the construction of the box. Although, the hinges for the door and the plastic insulator material used with the bussing are a bit cheesy. June 23, 2012
Rated 5.0 out of 5.0 by good load center, some difficulty ordering load center is fine but it took some time to order it. Went to Home Depot to order it due to some issues I was having on-line. I expected it to be easier to order at the store but it wasn't. They say "free delivery to the store" but in this case, it was delivered to me directly , no charge. I believe the web site ordering could be improved. I did get the item at the time they said I would . August 7, 2012
Rated 2.0 out of 5.0 by lights flicker after new panel install I bought this to upgrade from a panel that had no main shut off. I like the amount of space the panel offers and it has a main to kill the power so you can work on adding another breaker etc, before I replaced it, i had no problems except i couldn't turn of the power in the panel due to having no main shut off. Well now my lights flicker in my house, I've put a meter in a outlet on that circuit and the voltage drops when the lights flicker. also the a couple of the breakers have play in them and some off the neutral and ground bar screws were stripped or cross threaded, making it hard to tight, which was possible. also the retainer on the right side that the breakers hindge on snapped out when installing the breakers, it snapped back in but it just seems to me that this is a cheap panel. i was told to get a square-d but didn't think i needed to spend the money. wish i did now. i hope i can fix this mess because i don't plan on changing the panel again. lights flickered 13 times while doing this review. Later hope this helps your buying decision. April 13, 2010
  • 2016-10-30 T20:36:51.792-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_7, tr_7
  • loc_en_US, sid_100193092, prod, sort_default
1-7 of 7
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 87ms
  • REVIEWS, PRODUCT