T100 Series 40 Amp 125-Volt SPST 24 Hour Mechanical Time Switch with Indoor Enclosure

$48.98 /each
  • 1 to 12 On/Off operations per day, minimum On/Off time - 1 hour
  • 2 HP Rating
  • General purpose use-lighting, pool heaters, a/c, fans, pumps, etc

Frequently Bought Together

Product Overview

Intermatic is dedicated to providing energy conscious solutions and this time switch is designed for industrial, commercial and residential applications. It has the highest motor load rating in the industry. The original 'yellow dial' timer is just one product Intermatic offers for all your energy control needs.

  • Up to 12 on/off operations per day with minimum on/off times of 1 hour
  • 2 HP Rating
  • Manual override
  • 40 Amps per pole
  • CSA certified in US and Canada
  • General purpose use - Lighting, pool heaters, air conditioning, fans, pumps and more
  • Sturdy drawn steel enclosure with gray powder coat paint finish

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Product Depth (in.) 
Product Height (in.) 
7.8 
Product Width (in.) 

Details

Amperage (amps) 
40 
Color Family 
Gray 
Color/Finish 
Gray 
Electrical Features 
Programmable 
Electrical Product Type 
Timer 
Indoor/Outdoor 
Indoor 
Returnable 
90-Day 
Style 
Dial 
Timer Type 
Industrial Timer Switch 
Voltage (volts) 
125 
Wattage (watts) 
5000 

Warranty / Certifications

Certifications and Listings 
CSA Certified 
Manufacturer Warranty 
1 year 

More Products With These Features

Search

Customer Questions & Answers

8 Questions15 Answers

Customer Questions & Answers

T100 Series 40 Amp 125-Volt SPST 24 Hour Mechanical Time Switch with Indoor Enclosure
T100 Series 40 Amp 125-Volt SPST 24 Hour Mechanical Time Switch with Indoor Enclosure

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
4 answers

I want to use this as a dedicated timer for outlets for outdoor decor like x-mas lights. Is this possible?

This question is from T100 Series 40 Amp 125-Volt SPST 24 Hour Mechanical Time Switch with Indoor Enclosure
Asked by
Topeka,KS
Read all my Q&A
September 21, 2014
I want to use this as a dedicated timer for 4 or 5, 15 or 20 amp outdoor outlets for outdoor decor like x-mas lights. All outlets in turn would be on a dedicated breaker. Is this possible? Is this safe? Is there a cheaper or better way to get all my lights to come on and turn off at the exact same time on a residential level?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (4)

January 5, 2016
Answer: 
Yes
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Rome, NY
Read all my Q&A
Home Improvement Profile: DIYer
October 26, 2015
Answer: 
Only if the timer is in a protective enclosure as it's not weatherproof
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

December 10, 2014
Answer: 
Assuming you are using the 125VAC timer, it is used at our school for the outdoor night lights. As long as your lighting current draw is not more than 90% the rating of the contacts of the timer, you will be OK. It is preferable to run not more than 80%. The x-mas lights will be no problem if using LED unless you are entering a lighting contest with thousands of lights. If you maintain the current Read More
Assuming you are using the 125VAC timer, it is used at our school for the outdoor night lights. As long as your lighting current draw is not more than 90% the rating of the contacts of the timer, you will be OK. It is preferable to run not more than 80%. The x-mas lights will be no problem if using LED unless you are entering a lighting contest with thousands of lights. If you maintain the current rating, this is safe and less expensive than individual timers at the outlets. Also, less work if loss of power to reset the time. If you have never done this before, it would be better to hire an electrician. If you have a main breaker for the panel, just shut it off and do the work yourself. Yeah, it will require turning off everything in the house and reseting all the clocks, but electricians are expensive. You will have to pull the 12AWG (hot) load wire off the breaker and wire nut a black or red 12AWG wire to the load side of the timer. Run a black or red 12AWG wire from the breaker to the line side of the timer. Also, 12AWG green (ground) and white (neutral) wires will be needed from the breaker panel to the timer. Just connect the new wires to the same bars with the matching colors. Make sure the connections are tight, but don't have a gorilla tighten them. If this is being done outdoors, you will need liquid tight flex conduit and connectors to run the wiring in and a rain tight enclosure for the timer. Also, you MUST HAVE GFCI receptacles or a GFCI breaker for all exterior outlets for safety. Parts will be expensive, but it will last for years.
The Home Depot folks in electrical can provide help explaining what you need.
Read Less
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

October 8, 2014
Answer: 
Dear Valued HomeDepot Customer,
We reached out to the MFG for more information and below is their response.
"You should contact a local electrician so you can be in compliance with all your local codes."
-1point
0out of 1found this answer helpful.
Was this helpful?helpful0unhelpful1
 
3 answers

can I use it for water pump on my swing pool 2 horse power?

This question is from T100 Series 40 Amp 125-Volt SPST 24 Hour Mechanical Time Switch with Indoor Enclosure
Asked by
Read all my Q&A
November 20, 2015
can I use it for water pump on my swing pool 2 horse power?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
LaVergne, Tn
Read all my Q&A
Home Improvement Profile: DIYer
April 12, 2016
Answer: 
I have had this timer on my 2HP motor in-ground pool for several years and never had a problem other than losing the Trippers.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

Asked by
So Cal
Read all my Q&A
January 5, 2016
Answer: 
Yesw as long as the pump does not pull over 40amps
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

November 24, 2015
Answer: 
The T101D89 ratings do allow for up to a 2hp motor load at 120V so yes, you can use it for this application.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
2 answers

Could I set this up with a male and female plug so it could be portable?

This question is from T100 Series 40 Amp 125-Volt SPST 24 Hour Mechanical Time Switch with Indoor Enclosure
Asked by
Read all my Q&A
December 29, 2014
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

January 5, 2016
Answer: 
yes you could
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

January 8, 2015
Answer: 
Dear Valued HomeDepot Customer,
We reached out to the MFG for more information and below is their response.
"No, this timer is only meant to be hardwired and is not a portable unit. "
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
2 answers

I need just the timer dog with screw

This question is from T100 Series 40 Amp 125-Volt SPST 24 Hour Mechanical Time Switch with Indoor Enclosure
Asked by
st cloud mn
Read all my Q&A
June 14, 2014
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

December 10, 2014
Answer: 
Online at Home Depot
Intermatic
Model # 156T1978A
Internet # 100205118
Store SKU # 780081
Replacement Trippers for T100 Series Timers
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

June 19, 2014
Answer: 
Thank you for your recent inquiry with The Home Depot. Unfortunately, this item is not available for replacement parts through The Home Depot. However, it may be beneficial to reach out to the manufacturer of the product. The manufacturer is INTERMATIC and can be contacted at 815-675-7000. For more information, please visit your nearest Home Depot store or call HomeDepot.com customer service at Read More
Thank you for your recent inquiry with The Home Depot. Unfortunately, this item is not available for replacement parts through The Home Depot. However, it may be beneficial to reach out to the manufacturer of the product. The manufacturer is INTERMATIC and can be contacted at 815-675-7000. For more information, please visit your nearest Home Depot store or call HomeDepot.com customer service at 1-800-430-3376. Read Less
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
2 »
  • 2016-07-28 T15:09:23.532-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_100151619, prod, sort_default
2 »
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 168ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 4.0 out of 5 by 28 reviewers.
Rated 5.0 out of 5.0 by Great timer. Easy and accurate install directions. Works great. July 26, 2016
Rated 5.0 out of 5.0 by nice buy easy to install. did exactly what I had expected. thanks July 11, 2016
Rated 5.0 out of 5.0 by Easy to install and set time. Needed a heavy duty timer to control underwater lights for swimming pool, this should work for years. June 28, 2016
Rated 1.0 out of 5.0 by Junk Didn't work from day one, looses about 4 hours per day May 29, 2016
Rated 5.0 out of 5.0 by Intermatic Glad to see Home Depot getting Intermatic time clocks back in stock. It was gone for a short period of time & was missed. May 3, 2016
Rated 5.0 out of 5.0 by T100 timer straight foreword install easy to set up works as desribed February 10, 2016
Rated 5.0 out of 5.0 by Intermatic T100 Timer Works as expected. Easy to set up and install. Price is reasonable for what it does. Sales assistant was very helpful. December 8, 2015
Rated 5.0 out of 5.0 by High Quality unit Simple to install and operate. My only complaint is that you have to be sure to really tighten down the set screws or they will get loose and the unit will malfunction. October 26, 2015
  • 2016-07-28 T15:18:03.997-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_28, tr_28
  • loc_en_US, sid_100151619, prod, sort_default
2 >>
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 65ms
  • REVIEWS, PRODUCT