Model # TTV2006C

Internet #202216486

Reliance Controls 200 Amp Generator-ready Loadcenter with Meters
0851890000805

Reliance Controls

200 Amp Generator-ready Loadcenter with Meters

  • 200 amp whole house manual transfer panel
  • Acts as both a main panel and a manual transfer switch
  • Generator input is through a 60 amp double-pole circuit breaker
$44999 /each

Frequently Bought Together

Product Overview

The TTV2006C is a 200 Amp main breaker load center with a built-in 60A manual transfer switch. The TTV features 38 full-sized circuit breaker spaces and is approved for use the following branch circuit breakers: Siemens Type QP, QT, QPH, HQP, QE, QEH; Square D Series HOM to 100A maximum; Murray MP; C-H/Westinghouse Series BD, BR, BQ, GFC, TO 100A maximum. The TTV2003C panel is designed for use with generators up to 15,000 running watts. It includes a 200A main circuit breaker interlinked with a 60 Amp generator circuit breaker. The interlinked circuit breakers keep the generator isolated from the utility at all times, even with the deadfront removed. Use a power inlet box or power inlet kit for generator connection. The TTV2006C features built-in wattmeters, to help balance the generator load and is perfect for new construction, remodeling and service upgrades.

  • Heavy duty copper bus
  • Service entrance rated
  • Listed by Underwriters Laboratories Inc.
  • 5-year warranty

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

Bonded Neutral Generators

Does this panel have any provision for a generator with the neutral bonded to ground? In other words, when the transfer switch is in the generator position, will the neutral-to-ground connection be made at both the service panel and the generator, creating a loop and potentially tripping the GFCI outlets?
Asked by: Sparky
NO. The neutral and ground conductors between the generator and the panel will end up in parallel if you do not take steps. This is a no-no. Since the transfer is performed by the two-pole main and generator breakers which make and break only the two ungrounded circuit conductors this panel cannot switch the neutrals like some (three-pole) transfer switches do. The portable generator (if shipped from the manufacturer with the neutral bonded to the ground internally) must be reconfigured with the neutral NOT bonded to the ground. However, once you do that, then the generator should not be used to power devices plugged into the 120 volt outlets as this will create a potential shock hazard in the event of a malfunction (regardless of the GFCI protection provided at the generator), unless the generator neutral to ground bond is put back.The generator can be configured for one or the other but not both at the same time.
Answered by: SparkyRich
Date published: 2017-03-13

Will this panel accept GE Type TQP breakers?

Will this panel accept GE Type TQP breakers?
Asked by: Dave
This panel is UL listed for use with one inch interchangeable circuit breakers from Siemens, Square D, Murray, and Cutler-Hammer/Westinghouse but it is not for use with GE circuit breakers.
Answered by: RelianceControlsAnswers
Date published: 2017-05-02

What is maximum current rating of the buss bars?

What is maximum current rating of the buss bars?
Asked by: Milo
200 amps. The total value of the distribution breakers in the panel can be much larger than 200 amps, the panel will be protected from overload by the built-in main circuit breaker.
Answered by: RelianceControlsAnswers
Date published: 2017-04-02

Ok to mount this inside? and is there a flush kit?

Ok to mount this inside? and is there a flush kit?
Asked by: JD
This is an indoor load center that can be either surface or flush mounted. No additional kit is necessary for flush mounting.
Answered by: RelianceControlsAnswers
Date published: 2016-11-01
  • y_2017, m_6, d_23, h_12CST
  • bvseo_bulk, prod_bvqa, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_7
  • loc_, sid_202216486, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 95ms
  • QUESTIONS, PRODUCT

Customer Reviews

200 Amp Generator-ready Loadcenter with Meters is rated 4.8 out of 5 by 5.
Rated 4 out of 5 by from Decent wire bending space. Wattmeters only slightly in the way on main breaker lugs. Overall good... Decent wire bending space. Wattmeters only slightly in the way on main breaker lugs. Overall good product.
Date published: 2016-12-27
Rated 5 out of 5 by from Great Breaker Box... Extremely well built breaker box. The box weighed a ton with the solid copper bus bar and thick metal outer shell. A great safety feature is the back-feed mechanism that makes it impossible to have the 200-amp breaker and the transfer breaker on at the same time. Square D Homeline breakers fit like a glove. I highly recommend this box to anyone who wants a generator to power their entire breaker box and not just a few circuits.
Date published: 2011-11-26
Rated 5 out of 5 by from Great breaker box This box does it all. It has the generator transfer switch built right in and provides the watt meters so I can get maximum power out of my generator with out fear of overloading it. It is nice to have it all in one closed box.
Date published: 2011-10-18
Rated 5 out of 5 by from great product This is a super high quality product. It does exactly what I wanted it to do. By using this I did not have to set a sub panel for emergency circuits or buy and additional transfer switch. I can select what circuits I want to backup and change at any time.
Date published: 2013-06-11
Rated 5 out of 5 by from Well Built panel Installed the new panel this weekend. It is well built and has all the space you need for a 200 amp service. Only issue was when I switched over to test the generator, one of the watt meters did not work. Switched wires between current transducers and found one of the transducers to be bad. Called Reliance this morning and they said they would send me a nee transducer. Great product, GREAT customer service.
Date published: 2014-09-02
  • y_2017, m_6, d_23, h_24
  • bvseo_bulk, prod_bvrr, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_, sid_202216486, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 165ms
  • REVIEWS, PRODUCT