Product Overview

This Siemens ES Series Load Center is the smart choice for contractors when value and quick installation are of highest priority. The ES series Value Pack Load centers feature aluminum bussing, 10 year warranty, 100% neutrals, 3 Q120U circuit breakers and 1 Q230U circuit breaker and the ground bar is not included. The ES Series load centers include labor saving features such as the patented Insta-wire and mounting trim tabs. These exclusive features make the ES Series load center the best load center for the value minded contractor.

  • This is a single phase, 100 Amp main breaker load center with 10 spaces/20 circuits
  • Includes 2 Q115 single-pole 15 Amp breakers and 1 Q230 double-pole 30 Amp breaker
  • Aluminum bus
  • Features Siemens patented Insta-Wire technology which allows for quick and easy installation because screws are already backed out, ready for wire insertion on ground and neutral bars
  • Combination head screw on the neutrals, ground, trim, upper pan, and bond screw provide installation flexibility
  • All ES Series Load Centers allow the main breaker to be converted to main lug, but not vice versa
  • Single sided inboard neutral on 24 circuits and below; dual on 30 circuits and above
  • Mounting tabs on the trim hold the load center in place freeing up both hands to drive the trim screws
  • A rigid, sturdy base pan provides the ruggedness required for the harshest applications
  • NEMA type 1: Enclosure is intended for indoor use primarily to provide protection against contact with the enclosed equipment in locations where unusual service conditions do not exist
  • Learn More About Electrical Panels Here in our Buying Guide.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

Can a Murray style MP breaker be used with this load center?

Can a Murray style MP breaker be used with this load center?
Asked by: PhillyJason
Hello, this load center is designed to be used with our QP breaker series. Please do not hesitate to reach out if you have any other questions
Answered by: SIEMENS Product Expert
Date published: 2017-04-24

Is the 100 Amp Main Breaker 10,000 or 22,000 AIC (or) AIR rated ?

Is the 100 Amp Main Breaker 10,000 or 22,000 AIC (or) AIR rated ?
Asked by: olds87
The Main is 22K AIC rated
Answered by: SIEMENS Product Expert
Date published: 2017-04-03

If required by code, how is the "bonding bar" installed to the neutral bus bar?

If required by code, how is the "bonding bar" installed to the neutral bus bar?
Asked by: Confused
Hi, There is a bond screw provided with purchase of this panel, if the neutral needs to be bonded you would drive the bond screw into the can.
Answered by: SIEMENS Product Expert
Date published: 2017-01-30

Can I remove the 100A main and use a 60 amp breaker in its place for a 60A main?

Asked by: scott
Hi scott, Yes, you can remove the 100A main breaker and use a 60A instead. You can find the 2 pole 60A circuit breaker here: http://www.homedepot.com/p/Siemens-60-Amp-Double-Pole-Type-QP-Circuit-Breaker-Q260/100017724
Answered by: SIEMENS Product Expert
Date published: 2016-08-16
  • y_2017, m_6, d_25, h_14CST
  • bvseo_bulk, prod_bvqa, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_9
  • loc_, sid_100125954, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 72ms
  • QUESTIONS, PRODUCT

Customer Reviews

100 Amp 10-Space 20-Circuit Main Breaker Load Center Renovation Value-Pack is rated 5.0 out of 5 by 2.
Rated 5 out of 5 by from Easy to install Instructions were very helpful. This is the first time I've tackled a project of this size, but It's relatively easy to install a sub-panel. I had a quote from a pro for $800, and I ended up doing the whole job in an afternoon for $150. I'm not a tradesman, but this isn't rocket science - just do your homework and watch some online videos.
Date published: 2012-03-22
Rated 5 out of 5 by from
Date published: 2009-02-14
  • y_2017, m_6, d_25, h_2
  • bvseo_bulk, prod_bvrr, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasreviews, tv_1, tr_1
  • loc_, sid_100125954, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 70ms
  • REVIEWS, PRODUCT