Siemens 20 Amp Single-Pole Type QP Circuit Breaker
0783643070271

Siemens

20 Amp Single-Pole Type QP Circuit Breaker

  • Provides a manual means of energizing and de-energizing a circuit
  • Easy plug in connections in Siemens load centers and meter combos
  • Accepts #14-6 AWG Cu or #14-6 AWG Al Wire
$4.56 /each

Frequently Bought Together

Product Overview

Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.

  • Single pole, 20 Amp 120V type QP interchangeable circuit breaker
  • 10,000 AIC interrupting rating
  • Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
  • Compatible with Siemens PL and ES series load centers
  • Use for overload and short-circuit protection of your electrical system
  • Thermal-magnetic
  • Learn More About Circuit Breakers Here in our Buying Guide.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

12 Questions19 Answers

Customer Questions & Answers

20 Amp Single-Pole Type QP Circuit Breaker
20 Amp Single-Pole Type QP Circuit Breaker

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
2 answers

What breakers are compatible with ite gould

This question is from 20 Amp Single-Pole Type QP Circuit Breaker
Asked by
Read all my Q&A
May 11, 2016
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

May 13, 2016
Answer: 
Hi ron,
Siemens type QP circuit breakers are a direct replacement for ITE or Gould breakers and they will fit in ITE/Gould panels as well.
+4points
4out of 4found this answer helpful.
Was this helpful?helpful4unhelpful0

Asked by
St. Louis County, MO
Read all my Q&A
Home Improvement Profile: Professional
May 13, 2016
Answer: 
The Gould power distribution business was purchased by ITE and in the late '80s purchased by Siemens. The correct plug-on circuit breaker for either a Gould or ITE loadcenter is a Siemens Type QP.
+3points
3out of 3found this answer helpful.
Was this helpful?helpful3unhelpful0
 
2 answers

is this an arc fault breaker

This question is from 20 Amp Single-Pole Type QP Circuit Breaker
Asked by
Read all my Q&A
February 27, 2016
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
St. Louis County, MO
Read all my Q&A
Home Improvement Profile: Professional
March 16, 2016
Answer: 
No, this isn't an arc fault circuit breaker.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

February 29, 2016
Answer: 
Hi JA,
This is not an Arc fault circuit breaker. Our single pole 20 Amp arc fault circuit breaker can be found here: http://www.homedepot.com/p/Siemens-20-Amp-1-in-Single-Pole-Combination-AFCI-Circuit-Breaker-US2-QA120AFCP/205089995
+2points
2out of 2found this answer helpful.
Was this helpful?helpful2unhelpful0
 
2 answers

what voltage should I see?

This question is from 20 Amp Single-Pole Type QP Circuit Breaker
Asked by
Raleigh, NC
Read all my Q&A
February 27, 2016
Q120 single pole Siemens breaker. Three such in a box. Two seem to be working properly, but I'm only measuring 47 Volts output. The third shows 120V. Are the first two compromised somehow, or don't I know diddly about what I'm doing?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
St. Louis County, MO
Read all my Q&A
Home Improvement Profile: Professional
March 16, 2016
Answer: 
The first two could be bad breakers, but it would be unlikely to find two bad ones. More likely you have dropped a leg feeding the panel or have a bad main breaker. Check the voltage across the two main lugs in the panel, you should see 240 volts. Then check each main lug to neutral and to ground, you should see 120 volts in each test. If you have a main circuit breaker, perform both tests on the load Read More
The first two could be bad breakers, but it would be unlikely to find two bad ones. More likely you have dropped a leg feeding the panel or have a bad main breaker. Check the voltage across the two main lugs in the panel, you should see 240 volts. Then check each main lug to neutral and to ground, you should see 120 volts in each test. If you have a main circuit breaker, perform both tests on the load side of the main breaker too. If necessary, consult a qualified electrician. Read Less
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

March 3, 2016
Answer: 
Hi bfloxword,
Yes, in a typical residential service you should be seeing 120 volts on each phase. I would recommend that you reach out to a professional electrician to come out and take a look at your panel and diagnose any problem you may be having.
+2points
2out of 2found this answer helpful.
Was this helpful?helpful2unhelpful0
 
2 answers

Is this part interchangeable with a Q120AFC?

This question is from 20 Amp Single-Pole Type QP Circuit Breaker
Asked by
Read all my Q&A
January 25, 2016
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

February 7, 2016
Answer: 
The Q120AFC isn't interchangeable with the circuit breaker.
-2points
0out of 2found this answer helpful.
Was this helpful?helpful0unhelpful2

January 26, 2016
Answer: 
Hi Dcw,
You would be replacing an arc fault circuit breaker with a standard circuit breaker which could cause issues from a national electrical code standpoint. I would recommend that you reach out to an associate in the electrical department at your local Home Depot or consult a professional electrician.
+2points
2out of 2found this answer helpful.
Was this helpful?helpful2unhelpful0
2 »
  • 2016-10-30 T22:59:54.341-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_100044919, prod, sort_default
2 »
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 76ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 4.7 out of 5 by 10 reviewers.
Rated 5.0 out of 5.0 by Nice looking Its an Circuit Breaker... but has a nice appeal as compared to other CB. May 3, 2016
Rated 5.0 out of 5.0 by Quick delivery for original equipment breaker Needed to add a new 20 amp circuit. Used ship to store and item was available in 2 days, much sooner than promised. Breaker was very competitively priced and no freight charge by using ship to store. Great value. December 24, 2014
Rated 4.0 out of 5.0 by good used in Generac Pre-Wired Automatic Transfer Switch November 12, 2014
Rated 5.0 out of 5.0 by Just what I needed Hard to find circuit breakers for a 25 year old panel. I was amazed on the availability at a very reasonable price. Bought several spares. August 19, 2014
Rated 5.0 out of 5.0 by simply the best the best breaker you can buy, fits perfect , open screw ready for wire , tight fit on bus January 28, 2014
Rated 5.0 out of 5.0 by Exactly what I needed A very good price on these breakers. Same manufacturer as the panelboard they will be installed in. November 19, 2013
Rated 5.0 out of 5.0 by Works as expected .....great item easy to install! Works as expected .....great item easy to install! November 19, 2013
Rated 4.0 out of 5.0 by Breakers are as advertised (Only Should Be In Stock @ Store!!) Had to reschedule an installation because they were not in stock. Shipping was quick though. June 25, 2013
  • 2016-10-30 T21:11:16.864-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_10, tr_10
  • loc_en_US, sid_100044919, prod, sort_default
2 >>
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 57ms
  • REVIEWS, PRODUCT