Model # 20506201

Internet #202316484

Store SKU #658324

Southwire 1000 ft. 2/0 Black Stranded CU SIMpull THHN Wire
0032886234064

Southwire

1000 ft. 2/0 Black Stranded CU SIMpull THHN Wire

  • 2/0 AWG commercial wiring for outlets, switches and other loads
  • 2/0 Gauge THHN wire contains Copper (CU) Conductors
  • 2/0 THHN comes stranded with variety of colors and lengths
$289000 /each
store icon Loading Buying Options...
package icon Loading Buying Options...
Sorry, but we ran into issues loading these options. Please try refreshing.

Frequently Bought Together

Product Overview

  • 2/0 AWG commercial wiring for outlets, switches and other loads
  • 2/0 Gauge THHN wire contains Copper (CU) Conductors
  • 2/0 THHN comes stranded with variety of colors and lengths
Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the NEC 2. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90˚C. Conductor is suitable for use in wet or dry locations at temperatures not to exceed 90˚C or not to exceed 75˚C when exposed to oil or coolant.
  • THHN copper conductors are annealed (soft) copper, rated at 600-Volt and heat, moisture, gasoline and oil resistant
  • THHN cable is insulated with a tough heat and moisture resistant polyvinyl chloride (PVC)
  • THHN is available in a variety of colors, lengths and gauges; also available in solid and stranded copper
  • THHN cable is suitable for use in wet or dry locations at temperatures not to exceed 90˚C
  • UL listed
  • Note: product may vary by store
  • Click to learn the factors you must consider when wiring your home

Product Overview

Southwire Type THHN or THWN-2 conductors are primarily used in conduit and cable trays for services, feeders and branch circuits in commercial or industrial applications as specified in the NEC 2. When used as Type THHN, or T90 Nylon conductor is suitable for use in dry locations at temperatures not to exceed 90˚C. Conductor is suitable for use in wet or dry locations at temperatures not to exceed 90˚C or not to exceed 75˚C when exposed to oil or coolant.

  • THHN copper conductors are annealed (soft) copper, rated at 600-Volt and heat, moisture, gasoline and oil resistant
  • THHN cable is insulated with a tough heat and moisture resistant polyvinyl chloride (PVC)
  • THHN is available in a variety of colors, lengths and gauges; also available in solid and stranded copper
  • THHN cable is suitable for use in wet or dry locations at temperatures not to exceed 90˚C
  • UL listed
  • Note: product may vary by store
  • Click to learn the factors you must consider when wiring your home

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Product Depth (in.)
23.75
Product Height (in.)
18.5
Product Length (ft.)
1000 ft
Product Width (in.)
23.75
Wire/Cable Length (ft.)
1000

Details

Allowable Ampacities
Not Specified
Cable/Wire Type
THHN
Commercial / Residential
Commercial / Residential
Conductor Gauge
2/0
Conductor Material
Copper
Direct Burial
No
Electrical Product Type
Single Conductor Electrical Wire
Flame Retardant
No
Grounded
No
Indoor/Outdoor
Indoor/Outdoor
Jacketed
Yes
Number of Conductors
1
Outer Color
Black
Returnable
90-Day
Shielded
No
Stranded or Solid
Stranded
Sunlight / UV Resistant
No
Wet Location Use
Yes
Wire Cut Type
Pre-Cut Length

Warranty / Certifications

Certifications and Listings
1-UL Listed,CSA Listed
Manufacturer Warranty
NA

Specifications

Dimensions

Product Depth (in.)
23.75
Product Height (in.)
18.5
Product Length (ft.)
1000 ft
Product Width (in.)
23.75
Wire/Cable Length (ft.)
1000

Details

Allowable Ampacities
Not Specified
Cable/Wire Type
THHN
Commercial / Residential
Commercial / Residential
Conductor Gauge
2/0
Conductor Material
Copper
Direct Burial
No
Electrical Product Type
Single Conductor Electrical Wire
Flame Retardant
No
Grounded
No
Indoor/Outdoor
Indoor/Outdoor
Jacketed
Yes
Number of Conductors
1
Outer Color
Black
Returnable
90-Day
Shielded
No
Stranded or Solid
Stranded
Sunlight / UV Resistant
No
Wet Location Use
Yes
Wire Cut Type
Pre-Cut Length

Warranty / Certifications

Certifications and Listings
1-UL Listed,CSA Listed
Manufacturer Warranty
NA

More Products With These Features

Search

Questions & Answers

What are the dimensions and wieght of this roll

Asked by: dave
The dimensions are 13.5"H x 19.75"W x 19.75"D. WEIGHT 231.00
Answered by: SouthwireCustomerService
Date published: 2017-07-18

I have a 50 foot run to a sub panel from my exterior panel. This will be going through my attic a...

I have a 50 foot run to a sub panel from my exterior panel. This will be going through my attic and in the correct PVC. My T.I.G. welder at 230 volts will draw a maximum of 120 Amps. What size and designation of wire would you recommend. Cost of wire is not as important as safety. I do not ever wish for the wire to heat up. Thank You.
Asked by: Hal
Consult NEC Article 630 for the rules regarding electrical welders. Specifically, the rules regarding the ampacity of supply conductors for arc welders is located in NEC 630.11. Our recommendation is to use the correct size as required per the NEC and while 50' is not considered a long run, you may want to up-size the conductors anyway to be certain that voltage drop is not an issue. Use either individual THHN/THWN or XHHW conductors in PVC conduit. The above advice is based upon the current edition of the National Electric Code (NEC). Free access to the latest version of the NEC is available online at www.nfpa.org/freeaccess. The NEC and local building codes regulate the types of wire and cable that can be used in specific electrical applications, as well as the manner of installation. Check your local building codes before you start any wiring and cable electrical project and be sure to obtain required permits. When your work is complete, always have it inspected for compliance with local codes to ensure that it has been safely installed.
Answered by: SouthwireCustomerService
Date published: 2016-12-21

Good for 200 amp service?

I want to use this for a 200 amp service panel, and not sure about sunlight rating. 3 ft of it will be exposed to the elements. Is it o k to use?
Asked by: old
2/0 copper is approved for residential 200 amp service. If this is for a commercial 200 amp service you'll need to use 3/0 copper. Sunlight resistance is not an issue when using THHN in an overhead service.
Answered by: TomB2
Date published: 2016-08-19

100 AMP sub panel 120' run

installing electricity into my garage, underground from main to sub. what is recommended wire for this run?
Asked by: Randy
Assuming your garage is detached from the house, you'll need a 4-wire feeder. For a 100 amp feeder I'd use 3 - #3s and 1 - #8 ground all in conduit. If your subpanel has over 6 spaces you should buy a 100 amp main breaker panel as a disconnect is required. Do not install the neutral bonding screw in the panel, throw it away. Purchase and install a separate ground bar. The neutrals must be isolated from ground. Terminate all neutral conductors on the neutral bus and all ground conductors on the panel ground bar. You'll need to install at least 1 - 1/2" X 8' ground rod and connect it to the subpanel ground bar with #6 copper.
Answered by: TomB2
Date published: 2017-01-09
  • y_2017, m_9, d_23, h_21CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_11
  • loc_, sid_202316484, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 176ms
  • QUESTIONS, PRODUCT

Customer Reviews

  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 580ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;