The Southwire Company 500 ft. 10-3 UF Wire Gauge Service Entry Electrical Cable can be used in wet or dry locations and withstand temperatures up to 90˚C or 194˚F. This cable can be used for underground applications.

  • Feeder to outside post lamps, pumps and other loads or apparatus fed from a distribution point in an existing building
  • For use underground, including direct burial
  • For outdoor use
  • 600-Volt maximum
  • For wet or dry locations up to 90˚C or 194˚F
  • 500 ft. of cable
  • Copper conductor
  • UV and sunlight-resistant
  • 1-UL listed
  • Note: product may vary by store
  • Click to learn the factors you must consider when wiring your home

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

4 Questions5 Answers

Customer Questions & Answers

500 ft. 10-3 Gray Solid UF-B W/G wire
500 ft. 10-3 Gray Solid UF-B W/G wire

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
2 answers

line voltage drop

This question is from 500 ft. 10-3 Gray Solid UF-B W/G wire
Asked by
Virginia
Read all my Q&A
July 29, 2015
I am planning to run 450 feet cable along my driveway to light my front posts should i be worried about line voltage drop and if yes what cable you recommend
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
Boston, MA
Read all my Q&A
August 11, 2015
Answer: 
A big part of this is how much current are you going to draw? The voltage drop will increase with the current. If you use LED lighting in the posts, the current will be minimal and you probably won't even notice. Just make sure you run the correct size wire for the circuit: #14 for 15 amps, #12 for 20 amps.
If you have a whole bunch of 100W halogen or mercury bulbs, your current will be much higher
Read More
A big part of this is how much current are you going to draw? The voltage drop will increase with the current. If you use LED lighting in the posts, the current will be minimal and you probably won't even notice. Just make sure you run the correct size wire for the circuit: #14 for 15 amps, #12 for 20 amps.
If you have a whole bunch of 100W halogen or mercury bulbs, your current will be much higher and
you may want to go 1 or 2 wire sizes larger to minimize the drop.
Read Less
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

August 5, 2015
Answer: 
You are correct – for an installation of that length, voltage drop is a major concern and you will need to upsize your conductors (depending upon the current needed). You can use the voltage drop calculator on the Southwire website:
http://www.southwire.com/support/voltage-drop-calculator.htm
To compute the voltage drop, you will need to know the current needed by the load (lights) and the voltage. Do Read More
You are correct – for an installation of that length, voltage drop is a major concern and you will need to upsize your conductors (depending upon the current needed). You can use the voltage drop calculator on the Southwire website:
http://www.southwire.com/support/voltage-drop-calculator.htm
To compute the voltage drop, you will need to know the current needed by the load (lights) and the voltage. Do not be surprised if you have to increase the wire size by quite a lot – 450 feet is a long distance to run 120V wiring. Read Less
+3points
3out of 3found this answer helpful.
Was this helpful?helpful3unhelpful0
 
1 answer

Is this the right wire in conduit that I need to run 400 feet of cable underground to my garage for a hundred amp servic

This question is from 500 ft. 10-3 Gray Solid UF-B W/G wire
Asked by
Read all my Q&A
May 31, 2016
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answer (1)

June 6, 2016
Answer: 
No, 400 feet is a very long run; therefore, it would require a much larger wire. 1 conductors per phase utilizing a #500 Copper conductor will limit the voltage drop to 2.76% or less when supplying 100.0 amps for 400 feet on a 120 volt system.The above advice is based upon the current edition of the National Electric Code (NEC). Free access to the latest version of the NEC is available online at Read More
No, 400 feet is a very long run; therefore, it would require a much larger wire. 1 conductors per phase utilizing a #500 Copper conductor will limit the voltage drop to 2.76% or less when supplying 100.0 amps for 400 feet on a 120 volt system.The above advice is based upon the current edition of the National Electric Code (NEC). Free access to the latest version of the NEC is available online at www.nfpa.org/freeaccess. The NEC and local building codes regulate the types of wire and cable that can be used in specific electrical applications, as well as the manner of installation. Check your local building codes before you start any wiring and cable electrical project and be sure to obtain required permits. When your work is complete, always have it inspected for compliance with local codes to ensure that it has been safely installed. Read Less
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0
 
1 answer

Will this fit in 3/4 conduit

This question is from 500 ft. 10-3 Gray Solid UF-B W/G wire
Asked by
Read all my Q&A
April 5, 2016
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answer (1)

May 16, 2016
Answer: 
We must first know what type of conduit you are using. Please use this link to confirm the size of conduit needed: http://www.southwire.com/support/conduit-fill-calculator.htm
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
1 answer

Is this cable CSA certified?.

This question is from 500 ft. 10-3 Gray Solid UF-B W/G wire
Asked by
Read all my Q&A
September 21, 2015
In the descriptor for the 10-3 south wire 250 foot, (same cable just 1/2 the length) it mentions that it is UL approved and CSA certified. But when I click on the 500 foot item it doesn't mention being CSA certified. Just wanting to confirm that this wire is CSA certified. Thanks.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answer (1)

October 13, 2015
Answer: 
Type UF-B cable is not recognized by the CEC. These products are not CSA certified. The description on the HD site is incorrect.
Type UF-B Cable: http://www.southwire.com/ProductCatalog/XTEInterfaceServlet?contentKey=prodcatsheet8
Type CU-NMWU Cable (Canadian product similar to Type UF): http://www.southwire.com/ProductCatalog/XTEInterfaceServlet?contentKey=prodcatsheet193
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
1 of 1
  • 2016-08-18 T13:34:19.335-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_202316609, prod, sort_default
1 of 1
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 112ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 5.0 out of 5 by 3 reviewers.
Rated 5.0 out of 5.0 by Wire Worked as designed with very low voltage loss over the 500' run. May 31, 2016
Rated 5.0 out of 5.0 by Good product, great service. Great price and free shipping . The other wire with the same specs but a different name brand and a hundred bucks more , makes no sense. Took me a half hour and a call to my electrician to find out that the other company wanted $100 more because they think their name is better. April 7, 2015
Rated 5.0 out of 5.0 by Seemed impossible Fact one: No one in Humboldt County could match the Home Depot price. Fact two: Southwire Company 500 ft. 10-3 UF Wire Gauge Service Entry Electrical Cable is what it is. Great cable. Fact three: Home Depot shipped the 90 pound spool to my home by UPS for free! Fact four: I didn't believe it was possible. But it was. It happened. 5+ stars. April 9, 2013
  • 2016-08-18 T13:46:08.228-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_3, tr_3
  • loc_en_US, sid_202316609, prod, sort_default
1-3 of 3
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 60ms
  • REVIEWS, PRODUCT