Model # 55417399

Internet #205001803

Southwire (By-the-Foot) 2-2-2-4 Black Stranded Al Quad Dyke URD Cable
0032886922695

Southwire

(By-the-Foot) 2-2-2-4 Black Stranded Al Quad Dyke URD Cable

  • Sold by the Foot
  • Add the Length Desired In Feet as Your Quantity and Add To Cart
$162 /feet
store icon Loading Buying Options...
package icon Loading Buying Options...
Sorry, but we ran into issues loading these options. Please try refreshing.

Frequently Bought Together

Product Overview

  • Sold by the Foot
  • Add the Length Desired In Feet as Your Quantity and Add To Cart
Southwire's Quadruplex URD is used for secondary distribution and underground service. It can be used for direct burial or in ducts. The aluminum conductors are made stranded, compressed and available paralleled. 3-phase conductors and one neutral conductor are cabled together to form the quadruplex cable configuration.

Product Overview

Southwire's Quadruplex URD is used for secondary distribution and underground service. It can be used for direct burial or in ducts. The aluminum conductors are made stranded, compressed and available paralleled. 3-phase conductors and one neutral conductor are cabled together to form the quadruplex cable configuration.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Product Depth (in.)
0.973
Product Height (in.)
0.973
Product Length (ft.)
1
Product Width (in.)
12
Wire/Cable Length (ft.)
1

Details

Allowable Ampacities
Not Specified
Cable/Wire Type
URD
Commercial / Residential
Residential
Conductor Gauge
2
Conductor Material
Aluminum
Electrical Product Type
Service Entry Electrical Cable
Grounded
No
Indoor/Outdoor
Outdoor
Jacketed
No
Number of Conductors
4
Outer Color
Black
Returnable
90-Day
Shielded
No
Stranded or Solid
Stranded
Sunlight / UV Resistant
No
Wet Location Use
Yes
Wire Cut Type
Cut By-The-Foot

Warranty / Certifications

Certifications and Listings
1-UL Listed,CSA Certified
Manufacturer Warranty
N/A

Specifications

Dimensions

Product Depth (in.)
0.973
Product Height (in.)
0.973
Product Length (ft.)
1
Product Width (in.)
12
Wire/Cable Length (ft.)
1

Details

Allowable Ampacities
Not Specified
Cable/Wire Type
URD
Commercial / Residential
Residential
Conductor Gauge
2
Conductor Material
Aluminum
Electrical Product Type
Service Entry Electrical Cable
Grounded
No
Indoor/Outdoor
Outdoor
Jacketed
No
Number of Conductors
4
Outer Color
Black
Returnable
90-Day
Shielded
No
Stranded or Solid
Stranded
Sunlight / UV Resistant
No
Wet Location Use
Yes
Wire Cut Type
Cut By-The-Foot

Warranty / Certifications

Certifications and Listings
1-UL Listed,CSA Certified
Manufacturer Warranty
N/A

More Products With These Features

Search

Questions & Answers

Can I use 2224 from my main breaker panel going 250 ft to another breaker panel for a 50 amp RV hookup?

Asked by: Wayno
Southwire is wrong. Yes, you can by code. Voltage drop is a recommendation, not a enforceable code requirement. If their calcs are correct you are barely out of limits at full load which I expect you will be will under 99% of the time. I don't think their calcs are correct though.
Answered by: Electroman
Date published: 2017-07-01

What size conduit do I need for 100 ft?

Asked by: DAE
Southwire is wrong again. 3 1/2" for 2-2-2-4? 2" is less than 40% fill.
Answered by: Electroman
Date published: 2017-06-29

According to Southwire, this cable is rated at 155 Amps for direct burial and 115 Amps in ducts. ...

According to Southwire, this cable is rated at 155 Amps for direct burial and 115 Amps in ducts. You state that this wire is rated at 90 Amps when used to supply a detached garage underground to a sub-panel. Is Southwire incorrect?
Asked by: Robottechman
According to limitations set forth by National Electric Code guidelines, the cable is required to have overcurrent protection (breaker or fuses) at 90 Amperes or less.
Answered by: MasterElectrician
Date published: 2017-02-28

What size wire do I need to run from pole to 200 amp service 350'

Asked by: john
you would need 2 conductors per phase utilizing a #750 Aluminum conductor will limit the voltage drop to 2.76% or less when supplying 200.0 amps for 350 feet on a 120 volt system. The above advice is based upon the current edition of the National Electric Code (NEC). Free access to the latest version of the NEC is available online at www.nfpa.org/freeaccess. The NEC and local building codes regulate the types of wire and cable that can be used in specific electrical applications, as well as the manner of installation. Check your local building codes before you start any wiring and cable electrical project and be sure to obtain required permits. When your work is complete, always have it inspected for compliance with local codes to ensure that it has been safely installed.
Answered by: SouthwireCustomerService
Date published: 2016-10-10
  • y_2017, m_9, d_20, h_22CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_57
  • loc_, sid_205001803, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 112ms
  • QUESTIONS, PRODUCT

Customer Reviews

(By-the-Foot) 2-2-2-4 Black Stranded Al Quad Dyke URD Cable is rated 4.3 out of 5 by 11.
Rated 1 out of 5 by from unmarked cable hard to identify If your not an electrician dont buy this URD cable...youll end up not knowing what wire is which at the end of a long run. Each wire is black with the exception of one wire which is stripped to identify neutral. Cant tell which one of the three remaining is hot or ground...bad choice of purchase. I was at other big box store across the street from HD a week later to purchase a 100 amp breaker for my subpanel since HD doesnt carry GE breakers over 60 amps and ended looking at their URD (2-2-2-4) cable which to my surprise was color coded. All four cables were color coded for the novice like myself
Date published: 2017-07-26
Rated 5 out of 5 by from The order was lost by the shipping company. The HD... The order was lost by the shipping company. The HD agent suggested that I cancel the original order and place a new order. She attached a no charge "express shipment" to the new order and it arrived in 3 days. The cable was perfect. Well satisfied.
Date published: 2017-07-25
Rated 3 out of 5 by from Poor marking Lines were not marked. Should have been able to distinguish the wires with out have to make them hot to find out which one is which. Seeing the lines are twisted together.
Date published: 2017-07-05
Rated 5 out of 5 by from 5 Star Review Rating provided by a verified purchaser
Date published: 2017-08-16
Rated 5 out of 5 by from need it to rewire the barn need it to rewire the barn
Date published: 2017-05-30
Rated 4 out of 5 by from Yes it was what I needed... Yes it was what I needed
Date published: 2017-09-05
Rated 5 out of 5 by from Did the trick! I think this stuff is certified for direct bury but I put it in 1 1/4 inch PVC conduit from my house to a sub panel in the barn/shop. Note: you would have a tough time pulling this wire through anything but a straight run. I therefore put the PVC bends and fittings on the wire and glued them in their final position after dry fitting the entire 150 feet run. The whole project turned out great. I burried the cable 2 feet deep and re-routed from the path of the original wiring which was in the same trench and along side the water supply line (not my work). The previous install was grossly inadequate and dangerous. Shipping time was reasonable, price was right, and I feel that I got my money's worth. This wire is good for its intended purpose and I would recommend it.
Date published: 2015-12-22
Rated 5 out of 5 by from Solid Wire. Super Fast Shipping. Super fast shipping. When I ordered, the delivery time was 2-3 weeks. Received the wire within 3 days. It arrived so fast that I overlooked it sitting in front of the house for an entire day (wasn't expecting it that fast)! I think I ordered on a Monday night and it was at my home by Thursday. Used this wire to power a sub-panel for a detached office off of the main dwelling. Needed 240v. Wire provided two hots (both 2awg), one neutral (2awg), and one ground (4awg). Running it on a 70amp breaker on the main panel. Great wire. Great price (cheaper than running the direct burial copper option, even when using conduit).
Date published: 2015-08-25
  • y_2017, m_9, d_20, h_22
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_11
  • loc_, sid_205001803, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 113ms
  • REVIEWS, PRODUCT