0785901977339

Square D

Model HOM2040M100PCVP

Internet #204836397

Store SKU #1000040024

Homeline 100 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Breaker Load Center with Cover - Value Pack

$55.97 /each
  • For residential or commercial power distribution
  • Engineered for faster installation with fewer connections
  • Less wiring, clean gutter

Frequently Bought Together

Product Overview

The Square D by Schneider Electric Homeline Value Pack 100 Amp 20-Space 40-Circuit Indoor Convertible Main Breaker Load Center for Plug-on Neutral breakers includes the cover, a selection of breakers and is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.

  • Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral combination arc fault breakers on any space
  • Each pole space accepts full-size, tandem or quad breakers
  • Ground and neutral bars accept up to (3) #10-14 equipment grounds
  • Includes (2) HOM120 Homeline 20 Amp single-pole circuit breakers, (1) HOM230 Homeline 30 Amp double-pole circuit breakers and a combination flush/surface cover
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Overhead/underground feed simply by rotating the device before installing
  • Single phase
  • Rated 120/240 VAC and 22,000 AIR short circuit current rating
  • Automatic flush adjusting cover requires less time to complete the job
  • Designed with straight-in mains to save expensive cable and time
  • Distributed split branch neutral with terminal screws backed out offering with up to 50% more terminals than UL requires increases wiring flexibility saving installation time and simplifies wiring
  • Thermoplastic interior assembly is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • For protection from damage or theft on the job site, interiors can be easily removed with a single captive screw
  • 3-ground bar mounting locations (left, right and end) let you pick the easiest spot to wire
  • Made in the USA
  • Learn More About Electrical Panels Here in our Buying Guide.



  • Click here for more information on Electronic Recycling Programs

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

22 Questions44 Answers

Customer Questions & Answers

Homeline 100 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Breaker Load Center with Cover - Value Pack
Homeline 100 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Breaker Load Center with Cover - Value Pack

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
4 answers

main breaker question

This question is from Homeline 100 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Breaker Load Center with Cover - Value Pack
Asked by
Indian River MI
Read all my Q&A
July 21, 2014
Does the main 100 amp breaker come with this package? I am referring to the top main which does not show well in the photo nor is actually listed in the description.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (4)

Asked by
St. Louis County, MO
Read all my Q&A
Home Improvement Profile: Professional
September 24, 2015
Answer: 
Yes, this panel comes with a factory installed 100 amp main circuit breaker.
+5points
5out of 5found this answer helpful.
Was this helpful?helpful5unhelpful0

Asked by
Hoboken, NJ
Read all my Q&A
Home Improvement Profile: Professional
December 15, 2014
Answer: 
When the word main is in the description that is the key word to let you know a main breaker is in the panel. If it said indoor lug then it would not come with a main breaker.
+6points
10out of 14found this answer helpful.
Was this helpful?helpful10unhelpful4

July 23, 2014
Answer: 
Yes the HOM2040M100PCVP comes with a factory- installed main circuit breaker.
+18points
18out of 18found this answer helpful.
Was this helpful?helpful18unhelpful0

Asked by
york pa
Read all my Q&A
Home Improvement Profile: DIYer
July 22, 2014
Answer: 
The 100 amp Main breaker is preinstalled in the box
+9points
10out of 11found this answer helpful.
Was this helpful?helpful10unhelpful1
 
3 answers

How do you get 40 circuits from a box that supplies 20 breaker spaces

This question is from Homeline 100 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Breaker Load Center with Cover - Value Pack
Asked by
chicago illinois
Read all my Q&A
August 27, 2015
I have always thought that each breaker space provides you with only one protected circuit and adding two circuits to a breaker was not approved. So how does this work.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
St. Louis County, MO
Read all my Q&A
Home Improvement Profile: Professional
September 24, 2015
Answer: 
This is a 20 space, 40 circuit loadcenter. You can get up to a maximum of 40 circuits by using tandem circuit breakers in all 20 spaces.
+7points
7out of 7found this answer helpful.
Was this helpful?helpful7unhelpful0

August 28, 2015
Answer: 
You can use half size breakers to fit 40.
-4points
2out of 8found this answer helpful.
Was this helpful?helpful2unhelpful6

August 28, 2015
Answer: 
"The HOM20420M100PC load center in the HOM2040M100PCVP has 20 full spaces or 40 circuits by using tandem breakers and this is a UL tested and listed application and meets the appropriate NEC code. It only uses 20 single pole breakers for the 20 full spaces, or it can use 20 tandem breakers to get 40 circuits.
"
+10points
10out of 10found this answer helpful.
Was this helpful?helpful10unhelpful0
 
2 answers

Which Ground Bar?

This question is from Homeline 100 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Breaker Load Center with Cover - Value Pack
Asked by
Bordentown, NJ
Read all my Q&A
August 24, 2016
I recently purchased this load center and I am installing it as a subpanel in a detached shed/workshop. Which grounding bar should I purchase for this panel?

The grounding rod should be connected directly to the grounding bar, correct?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

August 25, 2016
Answer: 
PK18GTA is separately ordered ground bar kit. Please confirm installation with local authorities having jurisdiction to ensure all local codes are met.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
St. Louis
Read all my Q&A
Home Improvement Profile: Professional
August 24, 2016
Answer: 
Since you have already purchased this loadcenter, check the label inside the panel door for the catalog number of the proper ground bar kit. Home Depot stocks many of them and you should be able to find the appropriate one with no problem. Discard the neutral bonding screw that came with the panel, the neutral bus must be kept isolated from the panel box. Yes, the ground rod connects to the new ground Read More
Since you have already purchased this loadcenter, check the label inside the panel door for the catalog number of the proper ground bar kit. Home Depot stocks many of them and you should be able to find the appropriate one with no problem. Discard the neutral bonding screw that came with the panel, the neutral bus must be kept isolated from the panel box. Yes, the ground rod connects to the new ground bar with #6 bare copper ground wire, either stranded or solid is Ok. Your feeder to the detached building subpanel must have 4 wires; 2 hots, 1 neutral and 1 ground. Read Less
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
2 answers

What size of knockouts on the bottom of panel

This question is from Homeline 100 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Breaker Load Center with Cover - Value Pack
Asked by
levittown pa
Read all my Q&A
July 27, 2016
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

July 28, 2016
Answer: 
On the HOM2040M100PCVP load center the bottom knockouts are found within the drawings, located at the following weblink: http://download.schneider-electric.com/files?p_Reference=PWFDS-SYRS-0080&p_EnDocType=CAD&p_File_Id=3576109707&p_File_Name=PWFDS-SYRS-0080.pdf
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0

Asked by
St. Louis County, MO
Read all my Q&A
Home Improvement Profile: Professional
July 28, 2016
Answer: 
On the bottom you'll find the same concentric knockouts as on the top; 1/2", 3/4", 1" and one up to 2 1/2".
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
2 »
  • 2016-08-29 T16:20:23.305-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_204836397, prod, sort_default
2 »
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 157ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 4.3 out of 5 by 8 reviewers.
Rated 5.0 out of 5.0 by getting better, get price of arc fault breakers a must shows good workmanship;/great thinking eliminating tails August 21, 2016
Rated 5.0 out of 5.0 by great buy, no hassle. Good product, good price, did the job, order was ready. No drama. August 16, 2016
Rated 5.0 out of 5.0 by square D Great product, ill recommend this to contactor license August 2, 2016
Rated 4.0 out of 5.0 by How to fix nuisance trips You cannot beat this box for value, great for a small house. But... the Homeline breakers will sometimes trip for no reason with certain loads. I had 2 20A circuits, 1 with microwave and other with chop saw, that would trip a couple times a week. Fortunately, Eaton makes a compatible breaker for about $6 that fixes the trip problem. Even if you have to buy 2 or 3 of these you are still money ahead. July 18, 2016
Rated 5.0 out of 5.0 by Excellent product This is the new plug on neutral panel, which means the plug on neutral CAFCI breakers don't require a pigtail. They snap in like a regular breaker. Saves time and space. This panel also accepts up to 40 circuits. You can use a tandem breaker throughout any slot in the panel. For the price it blows the competition away at 55.97. Competitors have only 20 spaces and does not accept tandem breakers for that price. September 15, 2015
Rated 4.0 out of 5.0 by Good Breaker Box for the price This Load Center was to be used as a Sub Breaker Box But Looks Like it can only be used as a Main Load Center. Does anyone Know if it can be set up for that ? To have the Net and Gnd set Not connected. etc. May 7, 2015
Rated 1.0 out of 5.0 by Does not accept Tandem Breakers I purchased the panel and while it has enough open slots, it only accepts HOM breakers and not HOMT/QO. Square D apparently does not make a tandem 20 amp space saver breaker for the HOM style panel. Meaning you cannot double up on the breakers with a tandem... and that stinks. October 15, 2014
Rated 5.0 out of 5.0 by Good bang for the buck after searching high and low I found this item on home depot web site. It is a good quality name brand and excellent price for the product. It is not the manufactures top of the line product but it can't be beat for the price. July 22, 2014
  • 2016-08-29 T17:50:58.388-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_8, tr_8
  • loc_en_US, sid_204836397, prod, sort_default
1-8 of 8
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 54ms
  • REVIEWS, PRODUCT