  • For residential or commercial power distribution
  • Engineered for faster installation with fewer connections
  • Less wiring, clean gutter
$43.88 /each

Frequently Bought Together

Product Overview

The Square D Homeline 125 Amp 20-Space 40-Circuit Indoor Convertible Main Lugs Load Center with cover for Plug-on Neutral breakers is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.

  • Includes a fully distributed neutral bar, allowing for the installation of Homeline plug-on neutral combination arc fault breakers on any space
  • Each pole space accepts full-size, tandem or quad breakers
  • Ground and neutral bars accept up to (3) #10-14 equipment grounds
  • Includes a combination flush/surface cover and is convertible to main breaker load center with a QOM1 main breaker (sold separately)
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Overhead/underground feed simply by rotating the device before installing
  • Single phase
  • Rated 120/240 VAC and 65,000 AIR short circuit current rating
  • Automatic flush adjusting cover requires less time to complete the job
  • Designed with straight-in mains to save expensive cable and time
  • Distributed split branch neutral with terminal screws backed out offering with up to 50% more terminals than UL requires increases wiring flexibility saving installation time and simplifies wiring
  • Thermoplastic interior assembly is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • For protection from damage or theft on the job site, interiors can be easily removed with a single captive screw
  • 3 ground bar mounting locations (left, right and end) let you pick the easiest spot to wire
  • Made in the USA
  • Learn More About Electrical Panels Here in our Buying Guide.



Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

4 Questions6 Answers

Customer Questions & Answers

Homeline 125 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Lug Load Center with Cover
Homeline 125 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Lug Load Center with Cover

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
2 answers

Is 125 amp main breaker included?

This question is from Homeline 125 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Lug Load Center with Cover
Asked by
Read all my Q&A
February 9, 2016
The picture does not look like it includes a main breaker. One previous question on here asked if it was included and the reply was "Yes it is included" but then another person asked about what main breaker they should buy because their purchase did not come with one. I just want to make sure, does this actually come with a main breaker or not?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

February 11, 2016
Answer: 
HOM2040L125PC does not include a main breaker. This load center is convertible to main breaker with addition of QOM1 main breaker kit (125A max); QOM125VH is 125A 2-pole main breaker kit.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

February 11, 2016
Answer: 
The final answer is NO. The photo is correct and the "other" Schneider customer rep is incorrect. If the photo does not convince you then look at the part number - HOM2040L125PC. All HomeLine part numbers will indicate if the panel is a main lugs or main breaker panel. All main lugs DO NOT include a main breaker. HOM2040 - HomeLine 20 spaces, 40 circuits - Then you see "L" that means main lugs. If you Read More
The final answer is NO. The photo is correct and the "other" Schneider customer rep is incorrect. If the photo does not convince you then look at the part number - HOM2040L125PC. All HomeLine part numbers will indicate if the panel is a main lugs or main breaker panel. All main lugs DO NOT include a main breaker. HOM2040 - HomeLine 20 spaces, 40 circuits - Then you see "L" that means main lugs. If you see "M" after the HOM2040 that means main breaker is included.
If you are looking for this panel with the MAIN BREAKER FACTORY INSTALLED then do a search on the Home Depot website for HOM2040M100PC.
Read Less
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
2 answers

DOES THIS PANEL INCLUDE A 125A MAIN BREAKER?

This question is from Homeline 125 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Lug Load Center with Cover
Asked by
CONCORD. CA
Read all my Q&A
March 29, 2015
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
New Jersey
Read all my Q&A
July 13, 2016
Answer: 
No this does not include a 125A main breaker. This is a main lug panel, which does not include a main breaker in the panel. If you need a panel with a main breaker it will say main breaker vs. main lug. another easy indication is the catalog number. If it reads HOM2040L125PC the L indicates Lug which indicates no main breaker is included. If it reads HOM2040M125PC the M indicates Main breaker which it Read More
No this does not include a 125A main breaker. This is a main lug panel, which does not include a main breaker in the panel. If you need a panel with a main breaker it will say main breaker vs. main lug. another easy indication is the catalog number. If it reads HOM2040L125PC the L indicates Lug which indicates no main breaker is included. If it reads HOM2040M125PC the M indicates Main breaker which it includes a main breaker in the panel. The PC at the end of both just means P = plug on neutral and C = combination cover for flush or surface mount. Read Less
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

March 30, 2015
Answer: 
Yes, HOM2040L125PC includes factory-installed 2-pole 125A main breaker.
-2points
0out of 2found this answer helpful.
Was this helpful?helpful0unhelpful2
 
1 answer

My panel did not include the main breaker, what breaker should I use?

This question is from Homeline 125 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Lug Load Center with Cover
Asked by
Read all my Q&A
September 30, 2015
I need the breaker number to complete installation
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answer (1)

October 1, 2015
Answer: 
QOM125VH is 2-pole, 125 Ampere main breaker kit for use with HOM2040L125PC.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
1 answer

will this accommodate 3 2 pole 40 amp breakers? What AWG do i need to run from the main panel?

This question is from Homeline 125 Amp 20-Space 40-Circuit Indoor Main Plug-On Neutral Lug Load Center with Cover
Asked by
Read all my Q&A
December 27, 2014
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answer (1)

January 6, 2015
Answer: 
20-circuit/40-space load center HOM2040L125PC will accommodate three HOM240, two-pole 40A branch circuit breakers. Each main incoming lug of the HOM2040L125PC will accept one #6 -2/0 AWG aluminum or one #6 - 1/0 AWG copper.
+1point
1out of 1found this answer helpful.
Was this helpful?helpful1unhelpful0
1 of 1
  • 2016-10-31 T00:59:46.482-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_204836356, prod, sort_default
1 of 1
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 50ms
  • QUESTIONS, PRODUCT

Customer Reviews

  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 133ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;