Model # HOM3040M200VP

Internet #202522993

Store SKU #439845

Square D Homeline 200 Amp 30-Space 40-Circuit Indoor Main Breaker Load Center with Cover Value Pack
0785901490685

Square D

Homeline 200 Amp 30-Space 40-Circuit Indoor Main Breaker Load Center with Cover Value Pack

  • For residential and commercial power distribution
  • Engineered to save time and money
  • Smart choice for contractors, remodelers, builders and homeowners
$99.97 /each

Frequently Bought Together

Product Overview

The Square D Homeline 200 Amp 30-Space 40-Circuit Indoor Convertible Main Breaker Load Center with Cover Value Pack is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.

  • Includes (3) HOM120 Homeline 20 Amp single-pole circuit breakers, (2) HOM230 Homeline 30 Amp double-pole circuit breakers, and a combination flush/surface cover
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Overhead/underground feed simply by rotating the device before installing
  • Single phase
  • Rated 120/240 VAC and 22,000 AIR short circuit current rating
  • Automatic flush adjusting cover requires less time to complete the job
  • Designed with straight-in mains to save expensive cable and time
  • Distributed split branch neutral with terminal screws backed out offering with up to 50% more terminals than UL requires increases wiring flexibility saving installation time and simplifies wiring
  • Thermoplastic interior assembly is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • For protection from damage or theft on the job site, interiors can be easily removed with a single captive screw
  • Factory installed equipment ground bar is factory installed
  • Made in the USA
  • Learn More About Electrical Panels Here in our Buying Guide.
  • Click here for more information on Electronic Recycling Programs

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

Is this cover available as a left hand door instead of right hand

Asked by: gapcdr
Unfortunately no it is not
Answered by: SchneiderCustomerCare
Date published: 2015-09-25

Do the breakers allow back feed for a solar system

If i were to install a 40 amp 2 pole breaker does it allow for back feed?
Asked by: Hayman
Please call our Technical Support group at 1-888-778-2733, option 1 then option 1, for further discussion of application requirements.
Answered by: SchneiderCustomerCare
Date published: 2016-02-21

Does this come with the grounding bar?

Asked by: cjpersic
Yes, it does.
Answered by: SchneiderCustomerCare
Date published: 2016-06-22

Can I use this to create a new circuit panel in an addition?

I am wanting to have a something that will support 3 rooms: Room 1: Half Bath - light and two outlets Room 2: Utility Room - 4 ceiling lights, 2 porch lights, washer, dryer, freezer, 6ft. baseboard heater and half a dozen other outlets Room 3: Office - Ceiling fan w/lights, another 3 small lights, computer, tv (and other electronics found in a small office), baseboard heater, window unit A/C and half a dozen other outlets Note: I will run all the wire and buy the materials, but will have a professional install the circuit panel.
Asked by: Leroy3333
Yes.
Answered by: SchneiderCustomerCare
Date published: 2015-10-09

Can this panel accept any tandem breakers. If so WHERE ? THX.

Asked by: ed
Tandem breakers can be used anywhere a regular breaker would fit.
Answered by: tgg2015
Date published: 2017-01-01

can I run a 100 amp breaker off this box as wire for it is 4-4-4-6 will that fit in grounding lugs

Asked by: Mike
Please call our Technical Support line at 1-888-778-2733, option 1, for further discussion.
Answered by: SchneiderCustomerCare
Date published: 2016-02-05

What is the mini breaker. How many is it rated for

Asked by: Tom
Its also know as a TANDEM breaker it is used to give 2 circuits while only using 1 space.. But the panel is supposed to show a listing as to how may can be used in a panel and what spaces they can occupy. Ex: last 4 spaces. This is normally on the door. where is it listed???
Answered by: Tom
Date published: 2016-02-22

Does this panel come with the 200 amp disconnect breaker?

Asked by: 7752
Yes
Answered by: tgg2015
Date published: 2016-11-04
  • y_2017, m_2, d_16, h_10CST
  • bvseo_bulk, prod_bvqa, vn_bulk_0.0
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_8
  • loc_, sid_202522993, prod, sort_[]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 270ms
  • QUESTIONS, PRODUCT

Customer Reviews

Homeline 200 Amp 30-Space 40-Circuit Indoor Main Breaker Load Center with Cover Value Pack is rated 4.2 out of 5 by 6.
Rated 5 out of 5 by from Good quality panel. Panel Installed easily replacing old 200 Amp General Switch panel with burnt main. This is a 30 space panel designed to take 40 circuits. That means that "tandem breakers", (thinner double pole breakers like 20-40-40-20 on two bus bars) will only go onto the bottom five bus bars (bottom 10 slots). This gives a 20 "regular" breaker and 20 "tandem" breaker capacity, for a total of 40 circuits. I did not use the grounding bars screwed down on the sides. Instead, I bonded the neutral bar to the case, and put my safety-grounds and neutrals in the same bars nearer to the center. All one common ground. That is the way the original panel was, so I copied this method. My old panel box would accept "Square D Homeline Breakers", but my old breakers would not go into the Square D box. (Backward but not forward compatible). So I bought all new Square D breakers (not a bad idea anyway). I installed three tandem Square D breakers (204020's) in the bottom of the panel, and had plenty of breaker space left over.
Date published: 2013-01-15
Rated 5 out of 5 by from Top of the line electrical panel Easy to install. Quality product. Separate ground terminal strip. Separate Neutral strip. Should cover the needs of most homes of 2800 sq. ft or less.
Date published: 2014-01-13
Rated 5 out of 5 by from Replaced Load Center for Less Than a Discontinued / Used Main Breaker We would have a light flicker only sometimes and when I went to the panel, I noticed that one of the main aluminum service leads was warm…as high as 110 degrees F! (which occurs when there is a high resistance in the circuit). I determined that the main breaker was failing (originally installed in 1987). So instead of trying to find a replacement discontinued Challenger brand 200A main breaker I replaced the panel, main breaker, and all circuit breakers in the panel for less. [Home Depot online happened to be having a sale on electrical panels...online only] I highly recommend Square D. Don't buy cheaper brands.
Date published: 2014-08-05
Rated 4 out of 5 by from Quality load center This is an exellent load center to replace an existing panel.
Date published: 2012-03-06
Rated 1 out of 5 by from This is a Load Center not a 200 AMP Main Breaker as advertised Very misleading description for the product. I was under the assumption that it is a 200 amp Main breaker load center when in fact it is just a load center rated at 200 amp. If I had the facts of what the product is verses what it is advertised, I would not have purchased it.
Date published: 2015-10-27
Rated 5 out of 5 by from Exactly what I wantewd at the best price! I need to upgrade my old breaker panel box and this was exactly what I needed and Home Depot had the best price.
Date published: 2016-02-13
  • y_2017, m_2, d_15, h_22
  • bvseo_bulk, prod_bvrr, vn_bulk_0.0
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_6
  • loc_, sid_202522993, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 35ms
  • REVIEWS, PRODUCT