Product Overview

The Square D 200 Amp 30-Space 40-Circuit Outdoor Combination meter Socket and Main Breaker Load Center is suitable for use as a combination service entrance device (CSED). This unit is ANSI certified and UL listed with a maximum 10,000 AIR. The combination service entrance device features a Ring-type meter cover with a single-phase, 4-jaw meter socket. It is suitable for overhead or underground service applications. Meets EUSERC Specifications. Surface mount. This CSED is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline CSEDs are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline CSEDs are engineered for fast installation and wire savings.

  • Homeline 200 Amp 30-space 40-circuit ring-type surface mount main breaker CSED
  • Suitable for use as service entrance equipment
  • Accommodates plug-on secondary surge arrestor and features a plug-in design for easy installation
  • Ring-type design with no bypass
  • For use with Homeline breakers only
  • NEMA type 3R enclosure for outdoor use
  • 4-jaw meter socket included in design
  • Designed with straight-in mains to save expensive cable and time
  • Thermoplastic interior assembly is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • UL listed and ANSI certified
  • Learn More About Electrical Panels Here in our Buying Guide.
  • Click here for more information on Electronic Recycling Programs

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

Are there knock-outs in this panel

I don't see any knock outs from the views pictured. I assume there on the bottom and the right hand side. But no views pictured of those. Does anybody know?
Asked by: Bobaluke
Please refer to drawing attached for knockout information. http://static.schneider-electric.us/docs/Electrical%20Distribution/Combination%20Service%20Entrance%20Devices/CSED-Meter%20Mains/SC%20Meter%20Mains/3190.pdf
Answered by: SchneiderCustomerCare
Date published: 2015-11-24

Example: How Square D dual pole breaker will not fit

I've recently purchased a Square D Model # CSEDVP1 Store SKU # 357846 Home line 200 Amp 30-Space 40-Circuit Outdoor Main Breaker Combination Service Device Value Pack at home depot and I'm having trouble finding breakers that will fit I need a 30 amp dual pole and a 50 amp double pole but everyone at Home Depot and at Lowes cannot help me because anything above a 20 amp single pole Square D breaker when it will not work it will not fit in the panel hub can you please help. Thanks Paul
Asked by: panel
Please call our Technical Support line for clarification and further discussion at 1-888-778-2733, option 1 then option 4.
Answered by: SchneiderCustomerCare
Date published: 2015-11-23

is this ringless or ringed

Just bought this and power company said i need ringless and looking to see if this can be ringless or do I have to replace entire unit for another model?
Asked by: sckottty
The CSEDVP1 includes a SC3040M200S Combination Service Entrance Panel, (2) HOM115, (5) HOM120 and (1) HOM250 branch circuit breakers. The SC3040M200S is ring type and can not be converted to ringless. The closest match we have in ringless is the RC2040M200C however you are losing 10 circuits with this model. Unfortunately we do not have a 30/40 available in ringless, unless you add in lever bypass. That model would be RC3040M200SL. In both instances, the breakers must be ordered separately as these are not available in value packs like the original model provided. If you have any other questions or concerns, please feel free to reach out to us directly at 888-778-2733 between the hours of 8a and 8p ET.
Answered by: SchneiderCustomerCare
Date published: 2015-12-19

does this box have lugs to connect 2/0 wires from a pole to mobile home breaker box

Asked by: ed2567
The CSEDVP1 includes a SC3040M200S Combination Service Entrance Panel, (2) HOM115, (5) HOM120 and (1) HOM250 branch circuit breakers. The SC3040M200S CSED main phase and neutral lugs accept a #4 AWG - 250 KCMIL copper or aluminum conductor. The service ground lug accepts a #14 - #2/0 AWG copper or a #12 - #2/0 AWG aluminum conductor.
Answered by: SchneiderCustomerCare
Date published: 2015-11-23
  • y_2017, m_5, d_24, h_23CST
  • bvseo_bulk, prod_bvqa, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_4
  • loc_, sid_100131874, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 140ms
  • QUESTIONS, PRODUCT

Customer Reviews

  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 141ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;