0785901447528

Square D

Model QO160M200PC

Internet #204246798

QO 200 Amp 60-Space 60-Circuit Indoor Main Plug-On Neutral Load Breaker Center with Cover

$324.51 /each
  • For residential or commercial power distribution
  • Engineered for faster installation with fewer connections
  • Less wiring, clean gutter, fast installation

Frequently Bought Together

Product Overview

The Square D QO 200 Amp 60-Space 60-Circuit Convertible Main Breaker Indoor Plug-on Neutral Load Center is UL listed for residential, commercial and industrial power distribution. This load center is built with a shielded, copper bus bar that is plated for reliability. QO load centers are tested and listed only for QO circuit breakers. QO load centers are the "World's Finest" designed with industry leading features for flexible application. QO load centers include features engineered for fast installation and wire savings.

  • Engineered for a quick plug-on neutral breaker connection on every circuit, fewer connections, faster installation, and no pigtails frees up gutter space
  • Includes a factory-installed 200 Amp main breaker and combination trim cover, door kit QOCDK60 sold separately
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Overhead/underground feed simply by rotating the device before installing
  • Single phase
  • Rated 120/240 VAC and 22,000 AIR short circuit current rating
  • Designed with straight-in mains to save expensive cable and time
  • Split branch neutral with terminal screws backed out offering with up to 50% more terminals than UL requires increases wiring flexibility saving installation time and simplifies wiring
  • Thermoplastic interior is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • Convertible mains allow you to meet changing job site requirements by field converting main breaker load centers to main lugs and vice versa
  • For protection from damage or theft on the job site, interiors can be easily removed with a single captive screw
  • 3 ground bar mounting locations (left, right and end) let you pick the easiest spot to wire
  • Made in the USA
  • Learn More About Electrical Panels Here in our Buying Guide.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

2 Questions5 Answers

Customer Questions & Answers

QO 200 Amp 60-Space 60-Circuit Indoor Main Plug-On Neutral Load Breaker Center with Cover
QO 200 Amp 60-Space 60-Circuit Indoor Main Plug-On Neutral Load Breaker Center with Cover

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
3 answers

Does this come with a Door? Or is a Door Kit required? What is the Part Number for a complete load breaker with cover and door?

This question is from QO 200 Amp 60-Space 60-Circuit Indoor Main Plug-On Neutral Load Breaker Center with Cover
Asked by
Clifton, VA
Read all my Q&A
January 8, 2015
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
St. Louis County, MO
Read all my Q&A
Home Improvement Profile: Professional
December 24, 2015
Answer: 
You didn't read closely enough.
•Includes a factory-installed 200 Amp main breaker and combination trim cover, door kit QOCDK60 sold separately
-1point
0out of 1found this answer helpful.
Was this helpful?helpful0unhelpful1

January 13, 2015
Answer: 
Cover QOC60UF and door kit QOCDK60 are both ordered separately for load center QO160M200PC.
0points
1out of 2found this answer helpful.
Was this helpful?helpful1unhelpful1

Asked by
Clifton, VA
Read all my Q&A
Home Improvement Profile: DIYer
January 12, 2015
Answer: 
While it does Include a combination trim cover, it also requires a door kit QOCDK60 sold separately.
Please review the description.
-1point
1out of 3found this answer helpful.
Was this helpful?helpful1unhelpful2
 
2 answers

Is ths for solar use with main disconnect at the top of panel rather in center?

This question is from QO 200 Amp 60-Space 60-Circuit Indoor Main Plug-On Neutral Load Breaker Center with Cover
Asked by
Concord, Ca
Read all my Q&A
January 30, 2015
Is ths for solar use with main disconnect at the top of panel rather in center? With all spaces for branch circuit breakers below the main disconnect? My solar installer needs to land a double pole circuit breaker at the bottom of the new panel.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
St. Louis County, MO
Read all my Q&A
Home Improvement Profile: Professional
December 24, 2015
Answer: 
Yes, the main breaker is at the top. You could potentially use this for solar applications.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

February 3, 2015
Answer: 
Please gather more details of the application and call Schneider Electric Technical Support at 888-778-2733, option 1 then option 4, for discussion.
-1point
0out of 1found this answer helpful.
Was this helpful?helpful0unhelpful1
1 of 1
  • 2016-08-24 T15:06:53.104-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_204246798, prod, sort_default
1 of 1
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 27ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 5.0 out of 5 by 1 reviewer.
Rated 5.0 out of 5.0 by Easy to install Plug-on Neutral circuit breakers saves space and are easy to install. December 23, 2014
  • 2016-08-23 T12:52:34.724-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_1, tr_1
  • loc_en_US, sid_204246798, prod, sort_default
1-1 of 1
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 74ms
  • REVIEWS, PRODUCT