Square D by Schneider Electric Homeline 200 Amp 30-Space 40-Circuit Indoor Main Breaker Load Center with Cover Value Pack-HOM3040M200VP at The Home Depot
Free shipping
Discontinued

Square D by Schneider Electric

Model # HOM3040M200VP

Internet # 202522993

Homeline 200 Amp 30-Space 40-Circuit Indoor Main Breaker Load Center with Cover Value Pack


Square D by Schneider Electric Homeline 200 Amp 30-Space 40-Circuit Indoor Main Breaker Load Center with Cover Value Pack
 

This item has been discontinued.
The Home Depot no longer carries this specific product.

$99.97 / each
Item cannot be shipped to the following state(s): AK,GU,HI,PR,VI

PRODUCT SOLD Online Only

In Stock

Loading...

PRODUCT OVERVIEW

Model # HOM3040M200VP

Internet # 202522993

The Square D Homeline 200 Amp 30-Space 40-Circuit Indoor Convertible Main Breaker Load Center with Cover Value Pack is UL listed for residential and commercial power distribution. This load center is built with a plated, aluminum bus bar that is tested and listed only for Homeline circuit breakers. Homeline load centers are designed for the value-minded contractors, remodelers, builders and homeowners. Homeline load centers are engineered for fast installation and wire savings.

  • Includes (3) HOM120 Homeline 20 Amp Single-Pole Circuit Breakers, (2) HOM230 Homeline 30 Amp Double-Pole Circuit Breakers, and a combination flush/surface cover
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Overhead/underground feed simply by rotating the device before installing
  • Single phase
  • Rated 120/240 VAC and 22,000 AIR short circuit current rating
  • The automatic flush adjusting cover requires less time to complete the job
  • Designed with straight-In mains to save expensive cable and time
  • Distributed split branch neutral with terminal screws backed out offering with up to 50% more terminals than UL requires increases wiring flexibility saving installation time and simplifies wiring
  • Thermoplastic interior assembly is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • For protection from damage or theft on the job site, interiors can be easily removed with a single captive screw
  • Factory installed equipment ground bar is factory installed

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

SPECIFICATIONS

Assembled Depth (in.)  3.75 in  Assembled Height (in.)  33.78 in 
Assembled Width (in.)  14.25 in  Certifications and Listings  1-UL Listed 
Electrical Product Type  Load Center  Indoor/Outdoor  Indoor 
Load Center Type  Main Breaker  Load center depth (in.)  3.75 
Load center height (in.)  33.78  Load center width (in.)  14.25 
Manufacturer Warranty  Square D warrants its single phase load centers, in a residential application, to be free from defects in material and workmanship under normal care and proper usage for a period of 10 years from the date of installation for HOMELINE load centers when used with the appropriate Square D HOMELINE branch circuit breakers.  Maximum Amperage (amps)  200 A 
Mounting type  Plug In  Number of Spaces  30 
Number of phases  Product Series  HomeLine 
Product Weight (lb.)  34.83 lb  Returnable  90-Day 
Voltage (volts)  120/240 

CUSTOMER REVIEWS

Rated 4.8 out of 5 by 4 reviewers.
Rated 5 out of 5 by Good quality panel. Panel Installed easily replacing old 200 Amp General Switch panel with burnt main. This is a 30 space panel designed to take 40 circuits. That means that "tandem breakers", (thinner double pole breakers like 20-40-40-20 on two bus bars) will only go onto the bottom five bus bars (bottom 10 slots). This gives a 20 "regular" breaker and 20 "tandem" breaker capacity, for a total of 40 circuits. I did not use the grounding bars screwed down on the sides. Instead, I bonded the neutral bar to the case, and put my safety-grounds and neutrals in the same bars nearer to the center. All one common ground. That is the way the original panel was, so I copied this method. My old panel box would accept "Square D Homeline Breakers", but my old breakers would not go into the Square D box. (Backward but not forward compatible). So I bought all new Square D breakers (not a bad idea anyway). I installed three tandem Square D breakers (204020's) in the bottom of the panel, and had plenty of breaker space left over. January 15, 2013
Rated 5 out of 5 by Replaced Load Center for Less Than a Discontinued / Used Main Breaker We would have a light flicker only sometimes and when I went to the panel, I noticed that one of the main aluminum service leads was warm…as high as 110 degrees F! (which occurs when there is a high resistance in the circuit). I determined that the main breaker was failing (originally installed in 1987). So instead of trying to find a replacement discontinued Challenger brand 200A main breaker I replaced the panel, main breaker, and all circuit breakers in the panel for less. [Home Depot online happened to be having a sale on electrical panels...online only] I highly recommend Square D. Don't buy cheaper brands. August 5, 2014
Rated 5 out of 5 by Top of the line electrical panel Easy to install. Quality product. Separate ground terminal strip. Separate Neutral strip. Should cover the needs of most homes of 2800 sq. ft or less. January 13, 2014
Rated 4 out of 5 by Quality load center This is an exellent load center to replace an existing panel. March 6, 2012
1-4 of 4

SHIPPING AND DELIVERY OPTIONS

Standard Shipping includes delivery by small parcel service. Processing time varies by product.


Orders for this item may be expedited for an additional fee.


Other Delivery Options:

Express and Expedited shipping options are also available. Estimated arrival times are available in checkout.


If product is eligible for shipping to AK, HI and US Territories additional transit time and remote surcharges may apply.