Return this item within 90 days of purchase.
Get an answer now with AI
AI-generated from the text of manufacturer documentation. To verify or get additional information, please contact The Home Depot customer service.
Air King's DRLC702 decorative exhaust fans with light provide stylish and effective ventilation for your bathroom or powder room. A nickel finish complements most decors. The moonstone glass light lens evenly disperses light throughout the room. The unit utilizes two 60W maximum incandescent bulbs or two 15W LED bulbs (bulbs not included). The effective 70 CFM motor is permanently lubricated for years of worry free operation. All functions can be wired to operate separately. The unit easily installs using the included adjustable hanging brackets or integrated mounting tabs and the 4″ round plastic duct connector with damper protects against backdrafts. Perfect for use in smaller bathrooms and powder rooms.
Housing Length (in.) | 7.625 |
|---|---|
Housing Width (in.) | 7.375 |
Product Height (in.) | 9 in |
Product Width (in.) | 13.25 in |
Air Volume (CFM) | 70 |
|---|---|
Amperage (amps) | 1.6 |
Color/Finish | Nickel |
Duct Compatible Sizes | 4 in |
Features | Decorative, Light |
Grill Shape | Round |
Housing Material | Galvanized Steel |
Included | Hardware |
Installation Type | Ceiling |
Light Bulb Base Code | E26 |
Light Bulb Type Allowed | Fluorescent, Incandescent, LED |
Light Bulb Type Included | No Bulbs Included |
Maximum Light Bulb Wattage (watts) | 60 |
Maximum Room Size (sq. ft.) | 85 |
Mount Type | Recessed |
Number of Bulbs Required | 2 |
Pack Size | 1 |
Product Weight (lb.) | 13 lb |
Returnable | 90-Day |
Room Size | Medium Room Fan |
Voltage (V) | 120 V |
Wattage (watts) | 44 |
Manufacturer Warranty | 1 Year Limited |
|---|
Regular-sized bulbs.
The light could be put on a dimmer, the motor should not be on a dimmer. They can be wired separate, but if you tie them together to work off of 1 switch, it would be best to be a switch, not a dimmer!
Yes, it can be installed on a single switch. I personally prefer a timer for the fan, just to not burn the motor out should it remain on.
Yes it needs to be vented outside.
You will need to vent to the outside, like installing a drying vent.
Yes you should vent it outside.
I installed this in our 2nd floor bathroom and connected the vent to what we had previously there. It would require venting of some sort for the blower/ vent to function correctly.
This is more for a bathroom. I would use a range hood fan that is vented out for cooking.