The IPS size Yellow Poly Gas Pipe Transition Fitting allows you to transition from MDPE Yellow Poly Gas Pipe to metal pipe. One end of this Transition Fitting is plain IPS poly gas pipe that will connect to your run of poly pipe using one of the HOME-FLEX Underground fittings such as the Coupler, Tee or Elbow. The other end of this Transition Fitting has steel male pipe threads that you can use to couple to metal gas pipe. Be sure to use an appropriate thread sealant on the pipe threads.
Double Fitting Size | 2" x 2" |
|---|---|
Fitting 1 size | 2" |
Fitting 2 size | 2" |
Fitting Size Dimensions | 2" x 2" |
Single Fitting Size | 2" |
Application | Natural Gas, Propane |
|---|---|
Color Family | Yellow |
Compatible Pipe Material | Polyethylene |
Connection | Plain End x MPT |
Connection 1 | Plain End |
Connection 2 | MPT |
Connectivity | Threaded |
Features | Threaded, Underground Rated, Underground Use |
Fitting or Connector Type | Adapter |
Fitting/ Connector Collection | Polyethylene |
Material | Polyethylene |
Maximum working pressure (psi) | 90 |
Maximum Working Temperature (F) | 140 |
Pack Size | 1 |
Pipe or Fitting Product Type | Fittings & Connectors |
Product Weight (lb.) | 2.3 lb |
Returnable | 90-Day |
Manufacturer Warranty | 1 year |
|---|
Hello Kevin, yes, Home-Flex Underground polypipe is made from Medium Density Polyethylene (MDPE) and can be joined using fusion methods.
Hi Rick, Home Flex Underground poly gas pipe can be installed under a concrete patio. However, it must not be encased in concrete and must not be installed under a slab/patio on which there is a building / structure. Please see the link to the product’s installation manual for more details https://ipexna.com/en-us/resources/document-repository/home-flex-underground-system-design-installation-manual/
Please see IPEX's response.
Hello, the transition piece is installed as is. You do not shorten it. The fitting (coupler, tee, elbow etc) can be fit directly to the PE end of the transition fitting.
Yes, the Home Flex Underground PE pipe can be converted to black iron pipe under ground and the black iron run through the basement wall so long as the HFU poly pipe remains outside the building and is at – or below – the minimum required burial depth.
There are some important rules to follow when installing Home Flex Underground pipe: - do not install Home Flex Underground pipe above ground – it must always be buried to at least the depth required by your local building authority - do not install Home Flex Underground pipe inside or under buildings - do not encase Home Flex Underground products inside concrete There should never be an instance where Home Flex Underground pipe is connected to the underside of floor joists.
We would suggest that you show your plan to the building department in your area. We don’t know if the gas line you want to bring into the building via black iron pipe has been reduced in pressure through a regulator or not.
Galvanized pipe is not allowed for natural gas service.