Product Overview

Fix the knocking noise in your pipes by using the Homewerks Water Hammer Arrestors. The banging sounds in your pipes is caused by sudden stop in the flow of high speed water resulting in an increase in pressure. Water Hammer Arrestors absorb the shock created by the spike in pressure to stop the banging and prevent pipe damage. Homewerks Water Hammer Arrestors are designed for residential use and can be used for up to 3 plumbing fixtures. Various connection sizes and types are offered for your convenience.
  • California residents
  • Stainless steel construction
  • AA size, can be used for 1-3 fixtures
  • Certified lead free and certified to ASSE standards
  • Install between a supply stop and stub-out or a supply line
  • Max 250 psi
  • 3/8 in. compression connection
  • Stops banging in pipes and prevents pipe damage

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Water Pressure Regulators

3/4 in. Plastic Water Pressure Test Gauge
current product
3/8 in. Comp x 3/8 in. Comp Stainless Steel Straight Water Hammer Arrestor with No Lead
1/4 in. OD x 1/4 in. OD Female Compression Tee Copper Water Hammer Arrestor Type AA3/8 in. OD x 3/8 in. OD Female Compression Tee Copper Water Hammer Arrestor Type AA
BrandWattsHomewerks WorldwideThe Plumber's ChoiceThe Plumber's Choice
Name3/4 in. Plastic Water Pressure Test Gauge3/8 in. Comp x 3/8 in. Comp Stainless Steel Straight Water Hammer Arrestor with No Lead1/4 in. OD x 1/4 in. OD Female Compression Tee Copper Water Hammer Arrestor Type AA3/8 in. OD x 3/8 in. OD Female Compression Tee Copper Water Hammer Arrestor Type AA
Price
$998
$1286
$1999
/piece
$2477
/piece
Ratings
(403)
(48)
(12)
(5)
ConnectionFemale Hose ThreadSweatComp x CompComp x Comp
ApplicationPotable WaterPotable WaterNon-Potable Water,Potable WaterNon-Potable Water,Potable Water
Maximum Pressure (psi)2002506060
Compatible Pipe MaterialMulti-PurposeMulti-PurposeCopperCopper
MaterialPlasticStainless SteelCopperCopper
Maximum Working Temperature (F)140220180180
Valve TypePressure RegulatingPressure RegulatingPressure RegulatingPressure Regulating
Indoor/OutdoorIndoor,OutdoorIndoorIndoorIndoor
View ProductView ProductView ProductView Product

Specifications

Dimensions

Inlet Diameter (In.)
3/8
Outlet Diameter (In.)
3/8
Product Depth (in.)
0.87 in
Product Height (in.)
3.9 in
Product Length (in.)
3.9 in
Product Width (in.)
2.6 in

Details

Application
Potable Water
Compatible Pipe Material
Multi-Purpose
Connection
Sweat
Features
Lead Free
Indoor/Outdoor
Indoor
Material
Stainless Steel
Maximum Pressure (psi)
250
Maximum Working Temperature (F)
220
Pack Size
1
Product Weight (lb.)
0.379 lb
Returnable
180-Day
Valve Type
Pressure Regulating

Warranty / Certifications

Manufacturer Warranty
3 Year

Questions & Answers

3Questions9Answers

I installed an arrestor, and the response varies all the way from a quiet shutoff to a shutoff wi...

Asked by Zeke December 16, 2019
3
Answers

If you want to add a second arrestor, put it in series (end to end) with the exisitng arrestor. Also add copper tube straps if your piping is extremely loose. HD carries the tube straps.

Are both sides of the connection female? Doesn't one side have to be female (connect to supply) ...

Asked by MJ May 12, 2019
4
Answers

If you have a shut off and a flex line going to the sink. All you need to do is shut it off and unscrew compression nut at end of flex line. This comes with a compression fitting that unscrews (dis guard it) and then you have a male and a female on Arrestor. install unit in between shut off and flex line.

Can the arrestor work in a horizontal position?

Asked by Skip January 2, 2019
2
Answers

I believe it says it can be mounted in any direction.

Customer Reviews

  • 48 Customer Reviews
  • 3.3 out of 5 stars overall
42% of customers recommended.
Overall Ratings
5star-icon(16)
4star-icon(11)
3star-icon(5)
2star-icon(3)
1star-icon(13)
Sort By:
Problem Solved, and Quick!
Quality :
5
Value :
5
The Water Hammer Arrestor is what I've been looking for but didn't know it until I happened to search for it. I had always thought that water hammer arrestors had to be soldered into the mains, but I'd already closed up my walls and THEN I discovered the hammer problem. Further, I have PEX pipes, apparently they're not fastened down on horizontal runs enough, because they rattle when travelling across the cold-air return and HVAC supply trunks. I found this product online, ran to Home Depot to buy it, and after I came home got it installed in about 90 seconds. 1. turn off water 2. disconnect the cold water line on my sink (in my case the hammer was on the cold, but this product should work fine for hot too) 3. use an adjustable wrench to connect to the valve 4. use an adjustable wrench to connect the faucet line to the WHA. My water hammer is completely gone. BTW, the packaging diagram looks like it's got an actual bladder/plunger in it, not just an air chamber exposed to the water flow. Note: this unit has "male" on one end, and "female" on the other end. The photo shows a nut on the left side, which is discarded unless you need to run bare plastic/copper tubing to the faucet.
Was this helpful?
3
0
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
Was this helpful?
0
0
just didn't work .... waste of time and money (although...
just didn't work .... waste of time and money (although HD did accept the return). Installed an "empty" vertical capped pipe and it worked like a charm.
Was this helpful?
0
0
Bought two of these, for hot and cold connections to new kitchen sink faucet. Faucet was causing ...
Ease of installation :
4
Quality :
3
Value :
1
Bought two of these, for hot and cold connections to new kitchen sink faucet. Faucet was causing water hammer in pipes when shutting off flow. These did nothing to stop the water hammer, which still happens about the same as before installing them. They were easy to install, and appear well made, but they don't work.
Was this helpful?
0
0
Response from Homewerks WorldwideNovember 11, 2020
Hello Keoni, we are happy to assist and troubleshoot with you. Please give us a call 877-319-3757. Thank you. HomewerksWorldwide
works but needed 2
Got a very subtle hammer when turning on the hot water tap during cold season possibly due to pipe loosen around its fastener. Got 1 to put on the hot side and seems to helps abit so I got another to put on the cold side. Both seems to help but I would say 99.9% cause sometimes the hammer can be heard, but much much softer. Also don't expect it to work immediately. it took a few days before we notice it working, maybe due to the stiffen spring or rubber plunger, not sure.
Was this helpful?
0
0
Stopped the water hammer sound once installed....
Stopped the water hammer sound once installed.
Was this helpful?
0
0
Still hear the thumping, wish the chamber on top was bigger!
Still hear the thumping, wish the chamber on top was bigger!
Was this helpful?
0
0
Bought 3 to install in all our toilet tank connectors but this doesn't make even the smallest dif...
Ease of installation :
4
Quality :
3
Value :
1
Bought 3 to install in all our toilet tank connectors but this doesn't make even the smallest difference to water hammer/knocking pipes. Not worth it, cant return the 2 opened once but I will be returning the 3rd one. Some people have luck with it so I guess it works on very minor pressure or maybe other locations but not same for everyone, I advice to buy and try one before bulk ordering If anyone is thinking to do that.
Was this helpful?
0
0
Response from Homewerks WorldwideOctober 2, 2020
Hello NikWil, We are sorry to hear the water hammer arrestors have not resolved the hammering. We are happy to help with installation assistance, please call customer service with your model number. HomewerksWorldwide
Easy to install and solved the noise in pipes problem....
Easy to install and solved the noise in pipes problem.
Was this helpful?
0
0
minimized my water bang...
minimized my water bang
Was this helpful?
0
0
Review this Product
Share your thoughts with other customers