#1 Home Improvement Retailer

Internet #100140678

Model #67488

Store SKU #722669

Store SO SKU #184040

1-1/2 in. x 10 ft. PVC Schedule 40 Conduit

  • Designed for use above or below ground
  • PVC construction for fire and corrosion resistance
  • Features a UL listed design
  • See More Details

Frequently Bought Together

+
Price:

Product Overview

The JM eagle 1-1/2 in. x 10 ft. PVC Conduit protects and routes cables and conductors and is ideal for use aboveground or underground. The rigid Sch. 40 conduit is rated for 90°C conductors and is resistant to heat and corrosion.
  • Use in aboveground and underground installations
  • Non-metallic PVC is heat-, fire- and corrosion resistant
  • NEMA TC-2 rated
  • UL listed
  • Rated for 90° C conductors
  • 1 belled end and 1 plain end
  • Note: Product may vary by store

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Conduit

1/2 in. x 6 ft. Ultratite Liquidtight Flexible Non-Metallic PVC Conduit Whip1/2 in. x 25 ft. Ultratite Liquidtight Flexible Non-Metallic PVC Conduit
current product
1-1/2 in. x 10 ft. PVC Schedule 40 Conduit
BrandSouthwireSouthwireJM eagle
Name1/2 in. x 6 ft. Ultratite Liquidtight Flexible Non-Metallic PVC Conduit Whip1/2 in. x 25 ft. Ultratite Liquidtight Flexible Non-Metallic PVC Conduit1-1/2 in. x 10 ft. PVC Schedule 40 Conduit
Price
Ratings
(75)
(152)
(109)
Conduit typeNonmetallicNonmetallicNonmetallic
Length6 ft.25 ft.10 ft.
MaterialPVCPVCPVC
Size (in.)1/21/21-1/2
Trade Size (in.)1/21/21-1/2
Product Length (ft.)62510 ft
Product Width (in.)9.7511.501.9
View ProductView ProductView Product

Specifications

Dimensions

Length
10 ft.
Nominal inside diameter (in.)
1.610
Nominal outside diameter (in.)
1.900
Product Depth (in.)
120
Product Height (in.)
1.9
Product Length (ft.)
10 ft
Product Width (in.)
1.9
Size (in.)
1-1/2
Trade Size (in.)
1-1/2

Details

Color Family
Gray
Conduit type
Nonmetallic
Direct Burial
Yes
Electrical Product Type
Conduit
Flexible
No
Material
PVC
Package Quantity
90
Product Weight (lb.)
5.6

Warranty / Certifications

Certifications and Listings
UL Listed
Manufacturer Warranty
1 year

Questions & Answers

10Questions16Answers

how bendable is this product

Asked by sheen April 30, 2020
3
Answers

20 to 30 degrees cold with hot box 90 degrees

will this conduit hold 2-2-2-4 ?

Asked by Robert April 10, 2019
1
Answer

yes

Is this 1 1/2" conduit big enough for 1-1-1-3 aluminum SER cable?

Asked by Jk January 15, 2019
1
Answer

The three # 1 will fit but you will have heat build up when in use .

DOES THIS PRODUCT HAVE A PRESSURE RATING?

Asked by RM June 27, 2018
3
Answers

Yes. Not sure of the number, but was printed in red on the product when I purchased it.

Inside and out side dimensions not including bell. For 1-1/2 in.

Asked by Charlie February 20, 2018
1
Answer

1.6 in 1.9 in from the specifications table in the product page.

Can I stand this up 2 stories with 180 elbow on it without dropping it from being to heavy or too flimsy, clean gutters.

Asked by John December 1, 2017
2
Answers

Stihl makes a leaf blower that has the exact attachment you are looking for. MUCH lighter than PVC and it works well for me.

Can I run 4-6 circuits maximum 60 amps at 100 feet away from the main panel

Asked by paddy June 9, 2017
0
Answers

Is this product uv resistant

Asked by Ernie April 7, 2017
2
Answers

Most conduit is not uv resistant cause it go's underground.

can I use this pipe underground and how deep I gotta go

Asked by jr026 November 1, 2016
2
Answers

In ct its 18 inch to top of pipe for secondary power and 30 inch min underground for primary, dont forget the warning tape!

Would this work well if i install for a homemade heater for my pool

Asked by Mike March 12, 2016
1
Answer

Yes, this will work well.

1-1/2 in. x 10 ft. PVC Schedule 40 Conduit - page 2

Customer Reviews

  • 4.8
    out of 109 reviews
  • 100% recommend this product
Filter by:
Showing 1-10 of 109 reviews
Easy to cut with pipe cutter ratchet. Used to run speaker wires to rack enclosure in screen room ...
Easy to cut with pipe cutter ratchet. Used to run speaker wires to rack enclosure in screen room to deck
by Tim
1 person found this helpful
by Scot
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Works great for indoor and outdoor electrical work .Less expensive...
Works great for indoor and outdoor electrical work .Less expensive than metal conduit and easier to work with due to its flexibility over metal and easier to cut .
by DannyH
We purchased these 1 1/2" PVC conduit, 4 of them,...
We purchased these 1 1/2" PVC conduit, 4 of them, to serve as guides to help us align our 20' LOA, 8' Beam Ply on Frame Fiberglassed home-built boat onto and off the slipway that leads into the canal. The PVC conduit is driven into the canal's muddy bottom with 4' out of the water at high tide to serve this purpose. Highly recommended for this "other purpose" as they are rigid to stand up and not hurt the gunwale of the boat.
by captainsursea
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by
by HomeDepotCustomer
by MrJoshus
My husband purchased this PVC pipe to burry some lines....
My husband purchased this PVC pipe to burry some lines. Worked great for what we used it for.
by JDC