Model # LC110DFCGP

Internet #100171466

Store SKU #183327

Store SO SKU #516939

Murray 100 Amp 10-Space 20-Circuit Main Breaker Load Center Renovation Value Pack
0040892004748

Murray

100 Amp 10-Space 20-Circuit Main Breaker Load Center Renovation Value Pack

  • Includes (2) MP115 and (1) MP230 circuit breaker
  • Copper bus bar, closure plate included, HS type hub provision
  • Ideal for renovation
$6900 /each
store icon Loading Buying Options...
package icon Loading Buying Options...
Sorry, but we ran into issues loading these options. Please try refreshing.

Frequently Bought Together

Product Overview

  • Includes (2) MP115 and (1) MP230 circuit breaker
  • Copper bus bar, closure plate included, HS type hub provision
  • Ideal for renovation
Murray products have a rich tradition of quality and reliability that still lives on today. At the heart of the Murray offering is the Rock Solid load center – designed for those customers that prefer an out-board neutral design and metal base pan for installing breakers. The Rock Solid load center and Murray products remain an important part of the Siemens portfolio. Murray Rock Solid Load Centers are the highest quality, most versatile design in the industry.
  • Single phase, 100 Amp main breaker load center with 10 spaces/20 circuits
  • Copper buss bar for excellent conductivity
  • Includes 2 single-pole 15 Amp breakers and 1 double-pole 30 Amp breaker
  • “Swiss Cheese” style neutral bars provide multiple 1/0 connection points
  • All units include factory installed ground bar and isolated neutral
  • With the use of the included bonding strap, ground bars and neutral bars can be bonded for service entrance applications
  • Outboard neutral and ground bars allow for all neutral and ground connections to be located away from breaker connections, making for a neat, clean installation
  • Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws
  • All devices are convertible from main lug to main breaker or vice versa with the addition of main breaker or main lug kits
  • All main breakers are straight in wired – no back feeding required
  • A rigid, sturdy base pan with metal hook rails provides the most rugged breaker connection in the industry
  • All indoor rock solid load centers are invertible for bottom feed applications
  • NEMA type 1: enclosure is intended for indoor use primarily to provide protection against contact with the enclosed equipment in locations where unusual service conditions do not exist
  • Learn More About Electrical Panels Here in our Buying Guide.

Product Overview

  • Includes (2) MP115 and (1) MP230 circuit breaker
  • Copper bus bar, closure plate included, HS type hub provision
  • Ideal for renovation
Model #: LC110DFCGP
Sku #: 183327
Internet #: 100171466

Murray products have a rich tradition of quality and reliability that still lives on today. At the heart of the Murray offering is the Rock Solid load center – designed for those customers that prefer an out-board neutral design and metal base pan for installing breakers. The Rock Solid load center and Murray products remain an important part of the Siemens portfolio. Murray Rock Solid Load Centers are the highest quality, most versatile design in the industry.

  • Single phase, 100 Amp main breaker load center with 10 spaces/20 circuits
  • Copper buss bar for excellent conductivity
  • Includes 2 single-pole 15 Amp breakers and 1 double-pole 30 Amp breaker
  • “Swiss Cheese” style neutral bars provide multiple 1/0 connection points
  • All units include factory installed ground bar and isolated neutral
  • With the use of the included bonding strap, ground bars and neutral bars can be bonded for service entrance applications
  • Outboard neutral and ground bars allow for all neutral and ground connections to be located away from breaker connections, making for a neat, clean installation
  • Mounting tabs on the trim hold it in place on the load center, freeing up both hands to drive the trim screws
  • All devices are convertible from main lug to main breaker or vice versa with the addition of main breaker or main lug kits
  • All main breakers are straight in wired – no back feeding required
  • A rigid, sturdy base pan with metal hook rails provides the most rugged breaker connection in the industry
  • All indoor rock solid load centers are invertible for bottom feed applications
  • NEMA type 1: enclosure is intended for indoor use primarily to provide protection against contact with the enclosed equipment in locations where unusual service conditions do not exist
  • Learn More About Electrical Panels Here in our Buying Guide.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar

Price
$56.00 /each
$60.30 /each
$69.00 /each
$86.10 /each
Name QO 100 Amp 2-Pole Outdoor Circuit Breaker Enclosure with QO2100 Breaker Included 100 Amp 10-Space 20-Circuit Main Breaker Load Center Renovation Value-Pack 100 Amp 10-Space 20-Circuit Main Breaker Load Center Renovation Value Pack Homeline 100 Amp 20-Space 40-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover - Value Pack
Brand Square D Siemens Murray Square D
Ratings (3) (3) (1) (1)
View Product View Product View Product View Product

Specifications

Dimensions

Load center depth (in.)
16.5
Load center height (in.)
6.0
Load center width (in.)
15.8

Details

Electrical Product Type
Load Center and Breaker Kit
Indoor/Outdoor
Indoor
Load Center Type
Main Breaker
Maximum Amperage (amps)
100
Mounting type
Plug In
Number of Phases
1
Number of Spaces
10
Product Weight (lb.)
14.05lb
Returnable
90-Day
Voltage (volts)
120/240

Warranty / Certifications

Certifications and Listings
1-UL Listed
Manufacturer Warranty
1 Year

Specifications

Dimensions

Load center depth (in.)
16.5
Load center height (in.)
6.0
Load center width (in.)
15.8

Details

Electrical Product Type
Load Center and Breaker Kit
Indoor/Outdoor
Indoor
Load Center Type
Main Breaker
Maximum Amperage (amps)
100
Mounting type
Plug In
Number of Phases
1
Number of Spaces
10
Product Weight (lb.)
14.05lb
Returnable
90-Day
Voltage (volts)
120/240

Warranty / Certifications

Certifications and Listings
1-UL Listed
Manufacturer Warranty
1 Year

Questions & Answers

How do you get the door on

Asked by: Anonymous
Hi Johnglotfelter, The door should slide over the front of the panel and you would use the 4 trim screws that came with the panel to screw down and secure the door to the frame.
Answered by: SIEMENS Product Expert
Date published: 2017-01-01
  • y_2017, m_12, d_13, h_4CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_1
  • loc_, sid_100171466, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 130ms
  • QUESTIONS, PRODUCT

Customer Reviews

100 Amp 10-Space 20-Circuit Main Breaker Load Center Renovation Value Pack is rated 5.0 out of 5 by 1.
Rated 5 out of 5 by from I used this bundle to make a transfer switch panel for my portable generator. Combine this with ... I used this bundle to make a transfer switch panel for my portable generator. Combine this with siemens ECSBPK01 lockout adapter kit (fully compatible and listed on sticker in panel) and you have a mostly populated subpanel with generator lockout installed for less than 100 bucks. If you prefer to have the main and standby breakers on the same side, use lockout adapter ECSBPK02. Basically you are getting a free panel for buying a bunch of breakers, 100A, 30A, and 2x15A. Spent way too much time researching this stuff and this was the best deal i could find and i could get it all locally, even better. Panel is nice and roomy on the inside, unbonded neutral and separate ground bar installed and ready to go. Lockdown tab adapter is preinstalled for you on main breaker, main breaker and tab can be moved to other side. Panel is invertible.
Date published: 2016-12-14
  • y_2017, m_12, d_12, h_5
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_1
  • loc_, sid_100171466, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 125ms
  • REVIEWS, PRODUCT