The SaniCubic 2 is a pre-assembled heavy-duty duplex grinder pump that meets the demanding needs of commercial and residential sewage applications. The duplex-grinder system made of stainless steel liquefies solids into small particles prior to being passed through the 1-1/2 in. discharge. It is designed to handle multiple waste fixtures for applications such as residential single or group homes, commercial buildings, schools and many more. This new system consists of two 1 HP motors housed inside a compact but highly durable plastic enclosure. Each independently operating grinder has its own high-performance grinding system: a fast-rotating cutting blade to reduce solids in the wastewater stream from toilets, tubs and showers, sinks, washing machines, dishwashers, etc. The SaniCubic 2 operation is as simple as the installation. The effluent enters the pump through 1 of 5 different inlets - 1 on either side of the unit at the bottom and 3 along the top. The inlets can accommodate 1-1/2 in. or 4 in. of diameter pipes. As soon as the wastewater level reaches the trigger point, the pumping system activates. The effluent is then pumped out through 1-1/2 in. of diameter rigid pipe connected on the top of the pump. Maximum pumping distances are 36 ft. vertically and/or 328 ft. horizontally.
store icon Loading Buying Options...
package icon Loading Buying Options...
Sorry, but we ran into issues loading these options. Please try refreshing.

Frequently Bought Together

Installation Options

Product Overview

The SaniCubic 2 is a pre-assembled heavy-duty duplex grinder pump that meets the demanding needs of commercial and residential sewage applications. The duplex-grinder system made of stainless steel liquefies solids into small particles prior to being passed through the 1-1/2 in. discharge. It is designed to handle multiple waste fixtures for applications such as residential single or group homes, commercial buildings, schools and many more. This new system consists of two 1 HP motors housed inside a compact but highly durable plastic enclosure. Each independently operating grinder has its own high-performance grinding system: a fast-rotating cutting blade to reduce solids in the wastewater stream from toilets, tubs and showers, sinks, washing machines, dishwashers, etc. The SaniCubic 2 operation is as simple as the installation. The effluent enters the pump through 1 of 5 different inlets - 1 on either side of the unit at the bottom and 3 along the top. The inlets can accommodate 1-1/2 in. or 4 in. of diameter pipes. As soon as the wastewater level reaches the trigger point, the pumping system activates. The effluent is then pumped out through 1-1/2 in. of diameter rigid pipe connected on the top of the pump. Maximum pumping distances are 36 ft. vertically and/or 328 ft. horizontally.
  • Can handle up to 60 GPM from several fixtures
  • Dual motor for absolute reliability and power
  • Thermally protected and alarm mounted on the unit
  • Easy above the floor installation
  • Accepts accidental flushing of sanitary items such as feminine hygiene products
  • Note that the effluent pipe leading into the pump has to be installed with the required 1/4 in. per foot gravity flow; there must be a 10 in. of height difference (from pump to connecting fixture) if the drain is connected to the bottom inlet
  • Wastewater from other sanitary fixtures is discharged into the SaniCubic 2 via five 1-1/2 in. or 4 in. inlets, on either side of the housing and on the top of the enclosure; the internal discharge pipes come equipped with check valves that prevent back flow into the unit; isolating valves (ball, gate valves) must be installed on waste inlets and on the discharge pipe to ensure that any service/maintenance may be carried out safely
  • Unit has been designed with a 1-1/2 in. vent connection on the top of the enclosure; all plumbing codes require connection to a vent system; please note that the vent system should be a 2-way air vent; the use of mechanical vents, air admittance valves or similar devices are not permitted as these are considered 1-way air vent systems

Product Overview

Model #: 029
Internet #: 206262156

The SaniCubic 2 is a pre-assembled heavy-duty duplex grinder pump that meets the demanding needs of commercial and residential sewage applications. The duplex-grinder system made of stainless steel liquefies solids into small particles prior to being passed through the 1-1/2 in. discharge. It is designed to handle multiple waste fixtures for applications such as residential single or group homes, commercial buildings, schools and many more. This new system consists of two 1 HP motors housed inside a compact but highly durable plastic enclosure. Each independently operating grinder has its own high-performance grinding system: a fast-rotating cutting blade to reduce solids in the wastewater stream from toilets, tubs and showers, sinks, washing machines, dishwashers, etc. The SaniCubic 2 operation is as simple as the installation. The effluent enters the pump through 1 of 5 different inlets - 1 on either side of the unit at the bottom and 3 along the top. The inlets can accommodate 1-1/2 in. or 4 in. of diameter pipes. As soon as the wastewater level reaches the trigger point, the pumping system activates. The effluent is then pumped out through 1-1/2 in. of diameter rigid pipe connected on the top of the pump. Maximum pumping distances are 36 ft. vertically and/or 328 ft. horizontally.

  • Can handle up to 60 GPM from several fixtures
  • Dual motor for absolute reliability and power
  • Thermally protected and alarm mounted on the unit
  • Easy above the floor installation
  • Accepts accidental flushing of sanitary items such as feminine hygiene products
  • Note that the effluent pipe leading into the pump has to be installed with the required 1/4 in. per foot gravity flow; there must be a 10 in. of height difference (from pump to connecting fixture) if the drain is connected to the bottom inlet
  • Wastewater from other sanitary fixtures is discharged into the SaniCubic 2 via five 1-1/2 in. or 4 in. inlets, on either side of the housing and on the top of the enclosure; the internal discharge pipes come equipped with check valves that prevent back flow into the unit; isolating valves (ball, gate valves) must be installed on waste inlets and on the discharge pipe to ensure that any service/maintenance may be carried out safely
  • Unit has been designed with a 1-1/2 in. vent connection on the top of the enclosure; all plumbing codes require connection to a vent system; please note that the vent system should be a 2-way air vent; the use of mechanical vents, air admittance valves or similar devices are not permitted as these are considered 1-way air vent systems

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar

Price
$934.15 /each
$934.15 /each
$1,661.75 /pallet(lift)
$2,634.15 /pallet(lift)
Name SaniGrind Pro 1 HP 115-Volt Grinder Pump SaniBest Pro 1 HP 115-Volt Grinder Pump SaniCubic 1 1HP 115-Volt Grinder Pump SaniCubic 2 1HP 220/240-Volt Grinder Pump
Brand Saniflo Saniflo Saniflo Saniflo
Ratings (2) (11) (0) (0)
Solids Handling Yes Yes Yes Yes
Housing Material Thermoplastic Thermoplastic Thermoplastic Thermoplastic
Discharge Flow @ 0 ft. (gallons/hour) 1440 1620 50 60
Voltage (volts) 115 115 115 220
Horsepower (hp) 1 hp 1 hp 1 1 hp
View Product View Product View Product View Product

Specifications

Dimensions

Product Depth (in.)
20
Product Height (in.)
17
Product Width (in.)
24

Details

Amperage (amps)
13
Bottom/End Suction
No
Cord Length (ft.)
0
Discharge Flow @ 0 ft. (gallons/hour)
60
Discharge Flow @ 10 ft. (gallons/hour)
20
Hardware Required
Yes
Horsepower (hp)
1 hp
Housing Material
Thermoplastic
Maximum Working Temperature (F)
158
Minimum Sump Diameter
10 7/8 or Less
Minimum working temperature (F)
40
Outlet Connection
Clamp end
Power Type Required
AC
Product Weight (lb.)
17lb
Pump Switch Type
Diaphragm
Returnable
90-Day
Self-Priming
Yes
Solids Handling
Yes
Submersible
No
Voltage (volts)
220

Warranty / Certifications

Certifications and Listings
3-UL Classified,CSA Listed
Manufacturer Warranty
2 years prorated

Specifications

Dimensions

Product Depth (in.)
20
Product Height (in.)
17
Product Width (in.)
24

Details

Amperage (amps)
13
Bottom/End Suction
No
Cord Length (ft.)
0
Discharge Flow @ 0 ft. (gallons/hour)
60
Discharge Flow @ 10 ft. (gallons/hour)
20
Hardware Required
Yes
Horsepower (hp)
1 hp
Housing Material
Thermoplastic
Maximum Working Temperature (F)
158
Minimum Sump Diameter
10 7/8 or Less
Minimum working temperature (F)
40
Outlet Connection
Clamp end
Power Type Required
AC
Product Weight (lb.)
17lb
Pump Switch Type
Diaphragm
Returnable
90-Day
Self-Priming
Yes
Solids Handling
Yes
Submersible
No
Voltage (volts)
220

Warranty / Certifications

Certifications and Listings
3-UL Classified,CSA Listed
Manufacturer Warranty
2 years prorated

Questions & Answers

What does this discharge into? I have an old septic system & the 200' field line has failed. Is...

What does this discharge into? I have an old septic system & the 200' field line has failed. Is this one of the systems that do not require a long field line because water comes out clean?
Asked by: MountainGirl
I am sorry but you have just described a nightmare situation. Now maybe you are in a state where it is just a bad dream but I am in Massachusetts where a failed septic system can be a nightmare. There are incinerating toilets and composting toilets for those that want to get off the grid or are forced to.But for 99 plus percent of us, that do not have access to municipal service, a leaching field is necessary to repatriate the water back into the soil. The solids stay behind in the tank where they break down much like a compost. Periodically these solids may be removed and processed. Other than the off the grid options like the Incinolet and the composting toilets I do not know of any other products that do not require a septic system. In my experience when a septic system fails the board of health requires that a new system be engineered, approved and installed. Depending on the area and soils this can get extensive and expensive. Not to scare you but I have had friends who just could not afford it. So they installed a tight tank. They keep there water use to a minimum and have it pumped out ever few weeks. Now if your system requires pumps, some one needs to take great care in specifying them for the specific job. A pump that is oversize, undersized or wrongly applied can be of great annoyance. The calculations of needed flow rate and how much gravity you will be overcoming need top be done by someone who has a holistic understanding of the entire system. The correct pump, installed correctly will work great for years the wrong one results in great frustration. If you would like to speak about your specific situation you are welcome to give me a call. Chris 978 651 3301
Answered by: chris
Date published: 2017-07-05

How lomg is the warranty

Asked by: Edison
LIMITED WARRANTY Warranty period two-year from date of purchase Subject to the conditions listed below, SFA-SANIFLO INC. (hereinafter called the «Company») guarantees to repair or at its option replace the product or any component thereof, which, in the opinion of the Company, is faulty or below standard as a result of inferior workmanship or materials. If replacement is to be issued, this will only be extended to the first year starting from the date of purchase. Warranty repairs will apply after such date up to the warranty’s date of conclusion. CONDITIONS The conditions of this guarantee are: 1. The product must not have been subjected to misuse, neglect, accident or damaging products, in accordance with the paragraph «USAGE» of these Installation Instructions. 2. The product must be connected to the proper electrical supply as per the installation manual. 3.The alleged fault or defect must be notified to the company, within the warranty period. PART OR PRODUCT EXCHANGE The product will be exchange, free of charge, at the original resellers place of business only, upon the followings conditions being fullfilled: 1 The customer need a «return authorization» number from the company to authorize and validate the exchange. 2 The customer must supply a copy of their invoice to validate the request for an exchange. LIMITATIONS 1. Cost of disconnection and reconnection (ie labor charges) are not covered by the warranty and are end-users responsability. 2. Cost of mail or freight when a part or parts of the system have to be repaired at the company are not covered by this warranty. 3. In no event shall the company be reliable for any special, incidental or consequential damage, loss, or injury of whatsoever nature or kind arising from or in connection with the product or any component thereof. 4. The guarantee is transferable only when the product remains at the same premises as where it was installed initialy. Except as set forth in this Limited Warranty, the company disclaims all other warranties, express or implied, with respect to the product or any component thereof including, but not limited to, all implied warranties for merchantability and fitness for a particular purpose For service or for further inquiries, please call or contact any of the following addresses: United States Canada SFA-SANIFLO INC. SFA-SANIFLO INC. 105 Newfield Avenue, Suite A 1-685 Speedvale Avenue West Edison, NJ 08837 Guelph ON N1K 1E6 Toll Free: 1-800-571-8191 Toll Free: 1-800-363-5874 English Toll Free: 1-800-877-8538 French Telephone: 1-732-225-6070 Telephone: 1-519-824-1134 Fax: 1-732-225-6072 Fax: 1-519-824-1143 E-mail.: sfasales@saniflo.com E-mail.: sales@saniflo.com Web Site: www.saniflo.com Web Site: www.saniflo.ca
Answered by: chris
Date published: 2017-02-08
  • y_2018, m_6, d_17, h_23CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.8
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_, sid_206262156, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 93ms
  • QUESTIONS, PRODUCT

Customer Reviews

  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 125ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;