Model # QOCGK2C

Internet #203046553

Store SKU #345869

Square D QO 150-225 Amp Load Center Indoor Generator Interlock Kit
0785901489009

Square D

QO 150-225 Amp Load Center Indoor Generator Interlock Kit

  • For QO main breaker outdoor 150A - 225A electrical panels
  • Choose where to direct generator power to any circuit in the home
  • Includes interlock bracket, retaining bracket, and hardware
$4922 /each
store icon Loading Buying Options...
package icon Loading Buying Options...
Sorry, but we ran into issues loading these options. Please try refreshing.

Frequently Bought Together

Installation Options

Product Overview

  • For QO main breaker outdoor 150A - 225A electrical panels
  • Choose where to direct generator power to any circuit in the home
  • Includes interlock bracket, retaining bracket, and hardware
Avoid the inconveniences that an unexpected power outage can cause with this QO Indoor Generator Interlock Kit. The Square D QO Cover Generator and QOM2 Frame Size Main Breaker Interlock Kit is used to direct generator power to any circuit within your home. For use on "G" and "S" Series NEMA 1 and "G" and "S1" Series NEMA 3R load centers. Interlocks a QOM2 2 Pole main circuit breaker of a load center (150-225 A) with a QO 2 Pole (15-125 A) branch circuit breaker. Includes a retaining kit.
  • Use to interlock the QOM2 main breaker with a double-pole breaker back fed from a generator
  • Indoor unit
  • Choose where you want to direct generator power to any circuit within the home
  • Does not require a separate generator panel
  • Includes an interlock bracket, a retaining bracket, a 1-hole drilling template, 3 hex nuts, three 10-32 shoulder screws and an interior mounting screw
  • Wiring diagram and interlock translation labels also provided
  • Meets UL and ANSI safety requirements
  • Made in the U.S.A

Product Overview

  • For QO main breaker outdoor 150A - 225A electrical panels
  • Choose where to direct generator power to any circuit in the home
  • Includes interlock bracket, retaining bracket, and hardware
Model #: QOCGK2C
Sku #: 345869
Internet #: 203046553

Avoid the inconveniences that an unexpected power outage can cause with this QO Indoor Generator Interlock Kit. The Square D QO Cover Generator and QOM2 Frame Size Main Breaker Interlock Kit is used to direct generator power to any circuit within your home. For use on "G" and "S" Series NEMA 1 and "G" and "S1" Series NEMA 3R load centers. Interlocks a QOM2 2 Pole main circuit breaker of a load center (150-225 A) with a QO 2 Pole (15-125 A) branch circuit breaker. Includes a retaining kit.

  • Use to interlock the QOM2 main breaker with a double-pole breaker back fed from a generator
  • Indoor unit
  • Choose where you want to direct generator power to any circuit within the home
  • Does not require a separate generator panel
  • Includes an interlock bracket, a retaining bracket, a 1-hole drilling template, 3 hex nuts, three 10-32 shoulder screws and an interior mounting screw
  • Wiring diagram and interlock translation labels also provided
  • Meets UL and ANSI safety requirements
  • Made in the U.S.A

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar

Price
$49.22 /each
$49.22 /each
$62.25 /each
$76.63 /each
Name QO 150-225 Amp Load Center Indoor Generator Interlock Kit Homeline 150-225 Amp Load Center Indoor Generator Interlock Kit QO 100 Amp Load Center Outdoor Generator Interlock Kit ReplacementĀ PinsĀ for MR77
Brand Square D Square D Square D FLIR
Ratings (28) (15) (6) (0)
Product Width (in.) 0.57 4.5 1.7 0.8
View Product View Product View Product View Product

Specifications

Dimensions

Product Depth (in.)
7.9
Product Height (in.)
2.3
Product Width (in.)
0.57

Details

Electrical Product Type
Distribution Load Center / Breaker Accessory
Product Weight (lb.)
4.5lb
Returnable
90-Day

Warranty / Certifications

Certifications and Listings
1-UL Listed
Manufacturer Warranty
Square D/Schneider Electric warrants equipment manufactured by it to be free from defects in materials and workmanship for eighteen (18) months from date of invoice from Square D/Schneider Electric or its authorized sales channel.

Specifications

Dimensions

Product Depth (in.)
7.9
Product Height (in.)
2.3
Product Width (in.)
0.57

Details

Electrical Product Type
Distribution Load Center / Breaker Accessory
Product Weight (lb.)
4.5lb
Returnable
90-Day

Warranty / Certifications

Certifications and Listings
1-UL Listed
Manufacturer Warranty
Square D/Schneider Electric warrants equipment manufactured by it to be free from defects in materials and workmanship for eighteen (18) months from date of invoice from Square D/Schneider Electric or its authorized sales channel.

Questions & Answers

Will this work on qoc40uf square d box

Will this work on qoc40uf square d box
Asked by: Mike
Mike, you will need to bounce your model off the Square D web site to make sure you get the correct one. I did order the wrong one one my first try because I did not pay attention to the fact they make them for indoor box's and outdoor box's. So be sure to make sure you check that. If you order through Home Depot they do m as me returns real easy.
Answered by: Bulkydog
Date published: 2018-01-12

I have a QC816F200C panel. Will this kit QOCGK2C work with my panel?

I have a QC816F200C panel. Will this kit QOCGK2C work with my panel?
Asked by: Joe
I have installed many interlock kits on Square D panels with no issues. I have not installed an interlock on your model panel althought the spec sheet states that this is the interlock for Square D QO outdoor panels listed between 150-225 amp. With this said, I feel it will fit.
Answered by: SWPA
Date published: 2018-03-11

I have a Square D QO load center, cat. no. QOC 40MG225, Series L5. Will this interlock work with...

I have a Square D QO load center, cat. no. QOC 40MG225, Series L5. Will this interlock work with my panel?
Asked by: sparkythejesusfreak
I believe so. According to the product description, it works with the QOM2 main breaker. If you look at the specs on your 40MG225 you will see it comes with a main breaker QOM2200VH. Note that that breaker number starts with QOM2.
Answered by: MATT
Date published: 2018-01-29

Will this work with my panel. HOMC30UC I will be coming from the generators 50amp receptacle t...

Will this work with my panel. HOMC30UC I will be coming from the generators 50amp receptacle to a 50amp 2 pole breaker. Thanks
Asked by: Gordon
The selection of the correct Generator Interlock Kit is dependent upon the Series Number of the HOMELINE load center. The HOMC30UC is the cover only.Must use HOM interlock: See as follows for selection: The HOMCGK2C is compatible with any Series S, NEMA Type 1 (indoor); and Series S1, NEMA Type 3R (outdoor), convertible main, main breaker HOMELINE load center that utilizes a QOM2 frame main circuit breaker (150 - 225 ampere). It interlocks the QOM2 2-pole main circuit breaker with a back-fed HOM 2-pole (15-125 ampere) branch circuit breaker. A retaining means is also provided for the back-fed HOM branch breaker. NOTE: Convertible Main Lug Only load centers, that meets the description provided above, could also be used by converting the load center to a Main Breaker device. The HOMRBGK2C is compatible with any Series S2, S3 or S4 NEMA Type 3R (outdoor), convertible main, main breaker HOMELINE load center that utilizes a QOM2 frame main circuit breaker (150 - 225 ampere). It interlocks the QOM2 2-pole main circuit breaker with a back-fed HOM 2-pole (15-125 ampere) branch circuit breaker. A retaining means is also provided for the back-fed HOM branch breaker. NOTE: Convertible Main Lug Only load centers, that meets the description provided above, could also be used by converting the load center to a Main Breaker device. The HOMCRBGK1C is compatible with any Series S, NEMA Type 1 (indoor) or NEMA Type 3R (outdoor), convertible main, main breaker HOMELINE load center that utilizes a QOM1 frame main circuit breaker (100 - 125 ampere). It interlocks the QOM1 2-pole main circuit breaker with a back-fed HOM 2-pole (15-125 ampere) branch circuit breaker. The back-fed generator breaker amperage cannot exceed the amperage of the main breaker. A retaining means is also provided for the back-fed HOM branch breaker. NOTE: Convertible Main Lug Only load centers, that meets the description provided above, could also be used by converting the load center to a Main Breaker device. Regards, Customer Care
Answered by: SchneiderCustomerCare
Date published: 2018-03-19
  • y_2018, m_4, d_21, h_1CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.8
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_69
  • loc_, sid_203046553, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 32ms
  • QUESTIONS, PRODUCT

Customer Reviews

QO 150-225 Amp Load Center Indoor Generator Interlock Kit is rated 4.5 out of 5 by 28.
Rated 5 out of 5 by from Worked on my QO panel perfectly. Easy DIY job. I... Worked on my QO panel perfectly. Easy DIY job. I can utilize the whole panel now, within my wattage limits. I am very glad I went with this vrs a transfer switch.
Date published: 2018-01-09
Rated 3 out of 5 by from Works well enough, but expensive for what it is. In... Works well enough, but expensive for what it is. In fairness all the interlocks seem overpriced for what they are. It may be due to UL testing.
Date published: 2018-03-27
Rated 5 out of 5 by from installed well. decent template for hole locations. provides safe interlock for generator power t... installed well. decent template for hole locations. provides safe interlock for generator power to building. good installation instructions
Date published: 2018-03-20
Rated 5 out of 5 by from It's a good safety product. I installed myself, but I'm a electrician. You should have a professi... It's a good safety product. I installed myself, but I'm a electrician. You should have a professional to install.
Date published: 2018-03-21
Rated 5 out of 5 by from 5 Star Review Rating provided by a verified purchaser
Date published: 2017-11-02
Rated 1 out of 5 by from Did not fit my 125 amp panel box... Did not fit my 125 amp panel box
Date published: 2017-12-05
Rated 5 out of 5 by from This worked great ... This worked great
Date published: 2018-04-03
Rated 5 out of 5 by from I am an electrician with 40 years experience and don't work for Squared D. I have purchased elect... I am an electrician with 40 years experience and don't work for Squared D. I have purchased electrical products including transformers, panel boards, circuit breakers etc for almost 35 of those years. The support from Square D, the quality of their products, the clarity of install instructions and the uniformity of their products have made me a loyal customer. The pricing of this product is not just based on the cost to manufacture. This is a part that will often be installed by non-electricians, so there is an extra element of risk to the company. The design and prototype testing costs are also in the price. I have no hesitation in recommending Square D products (and their people).
Date published: 2017-01-08
  • y_2018, m_4, d_22, h_8
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.8
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_28
  • loc_, sid_203046553, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 36ms
  • REVIEWS, PRODUCT