Brand | Square D | Square D | Square D | Square D |
Name | QO 200 Amp 42-Space 52-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover | QO 150 Amp 42-Space 52-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover | QO 200 Amp 42-Space 52-Circuit Indoor Main Breaker Plug-On Neutral Load Center without Cover | QO 200 Amp 30-Space 30-Circuit Outdoor Main Breaker Plug-On Neutral Load Center |
Price | $22395 | $23500 | $24575 | $27621 |
Ratings | (115) | (10) | (1) | (20) |
Indoor/Outdoor | Indoor | Indoor | Indoor | Outdoor |
Number of Spaces | 42 | 42 | 42 | 30 |
Number of Circuits | 52 | 42 | 52 | 40 |
Load center height (in.) | 37.98 | 37.98 | 37.98 | 29.86 |
Load Center Type | Main Breaker | Main Breaker | Main Breaker | Main Breaker |
Electrical Product Type | Load Center | Load Center | Load Center | Load Center |
Mounting Type | Plug-On Neutral | Plug In | Plug-On Neutral | Plug-On Neutral |
Load center width (in.) | 14.25 | 14.25 | 14.25 | 14.75 |
Load center depth (in.) | 3.75 | 3.75 | 3.75 | 4.52 |
View Product | View Product | View Product | View Product |
![]() | ![]() | ![]() | ![]() | |
Brand | Square D | Square D | Square D | Square D |
Name | QO 200 Amp 42-Space 52-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover | QO 150 Amp 42-Space 52-Circuit Indoor Main Breaker Plug-On Neutral Load Center with Cover | QO 200 Amp 42-Space 52-Circuit Indoor Main Breaker Plug-On Neutral Load Center without Cover | QO 200 Amp 30-Space 30-Circuit Outdoor Main Breaker Plug-On Neutral Load Center |
Price | $22395 | $23500 | $24575 | $27621 |
Ratings | (115) | (10) | (1) | (20) |
Indoor/Outdoor | ||||
Number of Spaces | ||||
Number of Circuits | ||||
Load center height (in.) | ||||
Load Center Type | ||||
Electrical Product Type | ||||
Mounting Type | ||||
Load center width (in.) | ||||
Load center depth (in.) | ||||
View Product | View Product | View Product | View Product |
The neutral bar is not bonded to the enclosure unless you install the green bonding screw (which could be a teeny bit longer!). You must purchase ground bars separately. A lug panel would be cheaper, since you do not need a main breaker for a subpanel.
It is based on the rating from the mfg and the busing in the panel in question - not on the amperage of the service - typically there is a label located on the inside of the panel which will have a max allowable breaker size that can be installed
Like any other load panel, this 200A panel can support upto 40A 2-pole breaker for Solar inverter based on 120% NEC rule for generation tie-in.
The included cover/door is for either flush or surface installations.
Quick Open Craig the electrician
yes, after sheetrock is installed, it will be flush
Yes
This panel is approved to be inverted for bottom feed applications.
The neutral bus is isolated from the panel box when shipped from the factory. Throw the green bonding screw, which is shipped loose, away. Purchase and install a ground bar kit. You will need a 4-wire feeder to this panel; 2 hots, 1 neutral and 1 ground.
That usually depends upon your local inspector, but generally only 1 neutral wire per terminal, and 2 grounds per terminal IF they are the same size and material. Do not put a neutral and a ground on the same terminal.