Model # CQRA200

Internet #202353313

Store SKU #578533

Square D 200 Amp Overhead/Underground Meter Socket CSED
0047569291807

Square D

200 Amp Overhead/Underground Meter Socket CSED

  • Accommodates multiple wiring configurations
  • Aluminum Bus - Meter Main
  • OH/UG, NEMA 3R, Ring Type (Resi or Commercial)
$14300 /each

Frequently Bought Together

Product Overview

The Square D 200 Amp Residential Ring-type Meter Socket with no bypass surface mounts to provide for a single electric meter. It accommodates multiple wiring configurations for A size hub provision in the top end wall and a 2-1/2 in. maximum knockout in the bottom end-wall. The meter main uses an aluminum bus, is single phase, three wires, and features a NEMA 3R rated enclosure for outdoor use. This unit is ANSI certified and UL listed for use as service entrance equipment with a maximum load of 120/240 VAC. This 4-jaw meter socket is compatible with and neutral.

  • Square D 200 Amp ring-type 4-jaw single meter socket with no bypass
  • Accommodates an overhead or underground feed
  • Suitable for use as service entrance equipment
  • Ring-type design with no bypass
  • 120/240 VAC
  • Single phase, 3-wire design
  • NEMA type 3R enclosure for outdoor use
  • UL listed and ANSI certified
  • Click here for more information on Electronic Recycling Programs

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

For my run from this box to my house breaker panel, do I need 4 conductor wire or just 3 conductor wire?

I am trying to determine if I need 4/0-4/0-4/0-2/0 (al) ...or if I just need 4/0-4/0-2/0 between this box and my 200A main breaker panel (I will have appropriate ground rods at both locations)
Asked by: Butch
In short.. you must have 4 conductors. By code you must have the main bonding conductor at the first means of disconnect. So from that point you would have to 4 conductors (2 hot, 1 Grounded/neutral, 1 Equipment Grounding conductor. When in doubt call an electrician. GROUND RODS DO NOT PROTECT PEOPLE FROM SHOCKS. When in doubt call an electrician.
Answered by: throck
Date published: 2017-01-19

Just to be clear. Does this have the main breaker included. The cover is closed on the picture.

Asked by: mnausa
Yes.
Answered by: drh
Date published: 2017-03-15

Do they make these applications with the meter socket on the left and the switch on the right?

Asked by: Jaybird
No, CQRA200 is not offered with the meter socket on the left side. Regards, Schneider Electric Customer Care
Answered by: SchneiderCustomerCare
Date published: 2017-01-30

Does this unit have a 200 amp main breaker?

Does this unit have a 200 amp main breaker?
Asked by: Doug
Yes, CQRA200 includes factory-installed 200 Ampere 2-pole circuit breaker disconnect. Regards, Schneider Electric Customer Care
Answered by: SchneiderCustomerCare
Date published: 2017-01-23
  • y_2017, m_5, d_25, h_8CST
  • bvseo_bulk, prod_bvqa, vn_bulk_1.0.0-hotfix-1
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_11
  • loc_, sid_202353313, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 81ms
  • QUESTIONS, PRODUCT

Customer Reviews

  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 86ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;