Model # R62-03032-2WS

Internet #100356941

Store SKU #589535

Store SO SKU #162677

Leviton 30 Amp Industrial Double Pole Switch, White
0078477868539

Leviton

30 Amp Industrial Double Pole Switch, White

  • Top-Of-The-Line Industrial Quality
  • Heavy Gauge Copper Alloy One-Piece Arm for Top Performance
  • Large Silver Cadmium-Oxide Contacts for Long Life
$11.88 /each

Frequently Bought Together

Product Overview

Leviton Professional grade devices are built to the most demanding standards for performance and reliability. They're designed to withstand the highest abuse and resist impact and cracking. Ideal for residential, commercial and institutional applications. They are the preferred choice of electricians and contractors.

California residents: see   Proposition 65 information

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents.  Download a free copy from the Adobe Web site.

Specifications

Dimensions

Details

Warranty / Certifications

More Products With These Features

Search

Customer Questions & Answers

16 Questions27 Answers

Customer Questions & Answers

30 Amp Industrial Double Pole Switch, White
30 Amp Industrial Double Pole Switch, White

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
3 answers

Will this work with a 5 hp 80 gallon compressor as an emergency shutoff?

This question is from 30 Amp Industrial Double Pole Switch, White
Asked by
Denver, CO
Read all my Q&A
September 28, 2015
Compressor has a pressure switch with on and off but I want something close just in case. The fla is 22.5 on the motor plate. Thanks
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
Albakerky New Mexico, USA
Read all my Q&A
Home Improvement Profile: DIYer
August 9, 2016
Answer: 
yes
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Michigan
Read all my Q&A
June 11, 2016
Answer: 
Yes, just connect it in series with the contactor coil or if no contactor is present (unfortunate) connect it in series with the pressure switch.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

October 2, 2015
Answer: 
The 3032-2W 30 Amp switch is only rated for 2 HP max; this will not work for your application.
0points
1out of 2found this answer helpful.
Was this helpful?helpful1unhelpful1
 
3 answers

Can I use this switch to control something like a water heater that uses single phase 240v on a 30amp circuit?

This question is from 30 Amp Industrial Double Pole Switch, White
Asked by
Read all my Q&A
November 18, 2014
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (3)

Asked by
Albakerky New Mexico, USA
Read all my Q&A
Home Improvement Profile: DIYer
August 9, 2016
Answer: 
I can see no reason why not but I think the best way to go would be using the C/B panel.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Denver, Co
Read all my Q&A
Home Improvement Profile: Professional
November 21, 2015
Answer: 
Yes, but 2 things. #10 Copper solid 2/w gnd. No smaller, on a dedicated circuit. Once you are within 36" of that tank. Run the wire in seal tight. Here's why. If the tank ever breaches. Would you want to have to be standing water. And if the circuit is not protected by a GFCI breaker. And doesn't trip. You want to have to be reaching to shut off the power. With the switch being wet? Or have a family Read More
Yes, but 2 things. #10 Copper solid 2/w gnd. No smaller, on a dedicated circuit. Once you are within 36" of that tank. Run the wire in seal tight. Here's why. If the tank ever breaches. Would you want to have to be standing water. And if the circuit is not protected by a GFCI breaker. And doesn't trip. You want to have to be reaching to shut off the power. With the switch being wet? Or have a family member. thinking got to just turn off this switch? Even after youve turned off the supply water? Read Less
-4points
2out of 8found this answer helpful.
Was this helpful?helpful2unhelpful6

November 19, 2014
Answer: 
Good day, Yes, you can use the 30amp double pole switch for that application. David Keller, Leviton
+6points
6out of 6found this answer helpful.
Was this helpful?helpful6unhelpful0
 
2 answers

will this work on a 30 amp 240 volt 5000 watt garage heater?

This question is from 30 Amp Industrial Double Pole Switch, White
Asked by
manchester, NH
Read all my Q&A
September 11, 2016
Looking for an on off switch for my duraflame heater.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

September 15, 2016
Answer: 
I don't see why not, but you may want to contact the heater manufacturer for their recommendations, in case they have any special requirements.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

Asked by
Read all my Q&A
Home Improvement Profile: DIYer
September 14, 2016
Answer: 
I just used this to hook up a new air G73 garage heater. I ran 10-2 wire from the circuit breaker box to the switch and out to the heater.
User submitted photo
User submitted photo
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
 
2 answers

Can this switch used with a generator rated for 4500 watts for 120v application? What is the power rating?

This question is from 30 Amp Industrial Double Pole Switch, White
Asked by
Read all my Q&A
August 10, 2016
This switch is double pole double throw, correct?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answers (2)

Asked by
Michigan
Read all my Q&A
August 12, 2016
Answer: 
This switch is rated for 30 amps. At 120 volts the 30 amp rating means it is good for 3600 watts. I using it to turn on a 220 volt compressor rated at 21 amps and the switch has performed very well for over a year. This switch is a double pole single throw switch.
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0

August 12, 2016
Answer: 
The switch is a double-pole, single throw device. It is rated for 30A at 120/277V. If you need a DPDT switch, please look for the 1288-W,
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
2 »
  • 2016-10-31 T02:01:12.806-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_100356941, prod, sort_default
2 »
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 44ms
  • QUESTIONS, PRODUCT

Customer Reviews

30 Amp Industrial Double Pole Switch, White is rated 4.7 out of 5 by 13.
Rated 5 out of 5 by from The switch works perfectly. However, since 10 gage wire is to be used in conjunction with this sw... The switch works perfectly. However, since 10 gage wire is to be used in conjunction with this switch, I would suggest 10 gage stranded wire or if using solid wire use a large box to house the switch. It is a bit difficult to bend number 10 solid wire to seat the switch in a box standard size box.
Date published: 2017-01-11
Rated 5 out of 5 by from dpst switch Leviton makes a good product and it was exactly what I expected. What more can you ask?
Date published: 2016-08-09
Rated 4 out of 5 by from I would think rated with a 30 Amp capability the switch lever would have been RED I would think rated with a 30 Amp capability the switch lever would have been RED
Date published: 2016-12-06
Rated 5 out of 5 by from Works great This switch was easy to install and works well on my compressor.
Date published: 2016-09-27
Rated 5 out of 5 by from Appears to do what it was designed to do. Appears to do what it was designed to do.
Date published: 2016-11-29
Rated 5 out of 5 by from I'm using on a 5500 watt load Im not an expert but I shut off the main breaker to the whole house and installed this switch and I'm using it on a 240 volt 5500 watt load. It's working well and the terminals I used are the back terminals which allow the wire to be inserted and then tightened down. The screws can be tightened down no problem. This switch is model number 3032 and the wiring diagram is on the box. Circuit A 120v is on the left and circuit B 120v on the right. In case someone threw away the box The load is on top and the line(hot)is on bottom. This is just an on off switch. A larger junction box makes the difference with the 10 gauge wire. The diagram is confusing but I think I'm reading it right. I've installed the switch and everything is working. Thanks. It's best to go by the numbers on the diagram.
Date published: 2016-06-29
Rated 5 out of 5 by from Easy to install, works well turning a 220 volt compressor on and off! The switch was installed and working very well within 20 minutes. I'm very happy with this product.
Date published: 2016-06-12
Rated 5 out of 5 by from Exactly what I needed This is exactly what I was looking for to control my garage heater. I was unable to find any other options that would not require the use of a relay system. This was a simple and easy way to solve the problem of reaching the controls on the heater or forgetting to turn it on the way out of the garage for the night. Instructions are listed on inside the box and are easy to read, including a diagram. The throw is heavy and I can feel the quality over the standard duty switches of the same brand. The wires were all very easy to install and overall installation was smooth. I have no issue with the switch. However, I do not like that the industrial switches do no have the small border around the switch, so it looks like there is a bad fit between the switch and the plate. Also, I was hoping that the green (or red for the 20A single pole version) would be visible to discern circuits. Therefore, it would be nice to have these specialty industrial switches in specialty colors like green, red, black, and brown (though I realize that some of those colors indicate features of the switch or the circuit it controls).
Date published: 2013-03-07