500 ft. 2-2-2-4 Stranded AL URD Dyke Wire

$643.15 /each

Frequently Bought Together

Product Overview

Southwire Company 500 ft. 2-2-2-4 AL Quad Dyke Service Entry Electrical Cable can be used in applications up to 194˚F. This Cable is ideal for secondary distribution, street light applications and underground service up to 600-Volts. 1-UL Listed.

  • For secondary distribution, street light applications and underground service at 600-Volt or less
  • Designed for problematic installations due to adjacent utility work, homeowner or voltage surge damage
  • For direct burial or in ducts
  • For outdoor use
  • Can be used in temperatures up to 194˚F
  • 500 ft. of cable
  • Conductors are stranded, compressed aluminum and insulated with a vulcanized interlinked polyethylene insulation
  • Neutral conductor contains 3 yellow extruded stripes and sequential footage markers
  • Triplex construction made of 2 phase conductors and 1 neutral
  • URD has a visco-elastic sealant in the channels between the inner and outer layer
  • Design helps allow for cleaner stripping, more uniform sealant disbursement in the cable and great shrink-back performance
  • Note: product may vary by store

Specifications

Dimensions

Product Depth (in.) 
28 
Product Height (in.) 
24 
Product Length (ft.) 
500 ft 
Product Width (in.) 
28 
Wire/Cable Length (ft.) 
500 

Details

Allowable Ampacities 
not specified 
Cable/Wire Type 
URD 
Commercial / Residential 
Residential 
Conductor Gauge 
Conductor Material 
Aluminum 
Electrical Product Type 
Service Entry Electrical Cable 
Grounded 
No 
Indoor/Outdoor 
Outdoor 
Jacketed 
Yes 
Number of Conductors 
Outer Color 
Black 
Returnable 
90-Day 
Shielded 
No 
Stranded or Solid 
Stranded 
Sunlight / UV Resistant 
No 
Voltage (volts) 
600 
Wet Location Use 
Yes 
Wire Cut Type 
Pre-Cut Length 

Warranty / Certifications

Certifications and Listings 
1-UL Listed 
Manufacturer Warranty 
NA 

More Products With These Features

Search

Customer Questions & Answers

28 Questions15 Answers

Customer Questions & Answers

500 ft. 2-2-2-4 Stranded AL URD Dyke Wire
500 ft. 2-2-2-4 Stranded AL URD Dyke Wire

Ask your questions. Share your answers.

 
 
Clear Search Term
 
 
Sort By:
 
0 answers

Can I use this able to run from my 400 amp breaker thru my unimproved attic, out to detached garage 100amp sub-panel?

This question is from (By-the-Foot) 2-2-2-4 Black Stranded Al Quad Dyke URD Cable
Asked by
Read all my Q&A
July 13, 2016
Cable will only need to run 15ft outside the house (along slab) to the electrical PVC in footing.
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
 
0 answers

How would I splice this wire?

This question is from (By-the-Foot) 2-2-2-4 Black Stranded Al Quad Dyke URD Cable
Asked by
Massachusetts
Read all my Q&A
June 28, 2016
I have a 200 Amp main panel, and I am aware that this cant be used indoors, so how would I splice this on the outside of the house to go underground to a shed, then back at the shed to a indoor rated wire?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
 
0 answers

Using for shed.

This question is from (By-the-Foot) 2-2-2-4 Black Stranded Al Quad Dyke URD Cable
Asked by
North Huntingdon, PA
Read all my Q&A
June 26, 2016
I'll be using this wire underground to supply power to my shed. Does the wire where it enters the house and the shed where it will not be underground need to be in conduit?
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0
 
1 answer

can i use this to run underground to a 100amp sub-panel?

This question is from (By-the-Foot) 2-2-2-4 Black Stranded Al Quad Dyke URD Cable
Asked by
Read all my Q&A
June 13, 2016
i know i need 2 hot conductors a neutral and ground i think im just confused on the discription. The run will be about 130 feet"
0points
0out of 0found this question helpful.
Was this helpful?helpful0unhelpful0

Answer (1)

June 15, 2016
Answer: 
Yes you can but with this cable you cannot enter the building. A cable with a RHH/RHW/USE rating, such as mobile home cable, can be used and enter the building using conduit in the building.
This response is based upon the current edition of the National Electric Code (NEC). Free access to the latest version of the NEC is available online at www.nfpa.org/freeaccess. The NEC and local building codes Read More
Yes you can but with this cable you cannot enter the building. A cable with a RHH/RHW/USE rating, such as mobile home cable, can be used and enter the building using conduit in the building.
This response is based upon the current edition of the National Electric Code (NEC). Free access to the latest version of the NEC is available online at www.nfpa.org/freeaccess. The NEC and local building codes regulate the types of wire and cable that can be used in specific electrical applications, as well as the manner of installation. Check your local building codes before you start any wiring and cable electrical project and be sure to obtain required permits. When your work is complete, always have it inspected for compliance with local codes to ensure that it has been safely installed. Read Less
0points
0out of 0found this answer helpful.
Was this helpful?helpful0unhelpful0
2 3 »
  • 2016-07-27 T14:11:19.438-05:00
  • bvseo_lps, prod_bvqa, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasquestionsanswers
  • loc_en_US, sid_202316368, prod, sort_default
2 3 »
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 115ms
  • QUESTIONS, PRODUCT

Customer Reviews

Rated 4.8 out of 5 by 5 reviewers.
Rated 4.0 out of 5.0 by Good quality for the price The spool is sturdy. I had to drop it out of my truck at the job site but it held up well. The wire comes off the spool easily and the wire covering is not chaffing against the obstacles we have to thread through. January 6, 2015
Rated 5.0 out of 5.0 by Exactly What i Wanted Great wire Good Price. Ordered it for the sub panel in my garage. I recommend if placing this wire through PVC conduit to go bigger then 1-1/4 inch though. January 19, 2016
Rated 5.0 out of 5.0 by Did the trick! I think this stuff is certified for direct bury but I put it in 1 1/4 inch PVC conduit from my house to a sub panel in the barn/shop. Note: you would have a tough time pulling this wire through anything but a straight run. I therefore put the PVC bends and fittings on the wire and glued them in their final position after dry fitting the entire 150 feet run. The whole project turned out great. I burried the cable 2 feet deep and re-routed from the path of the original wiring which was in the same trench and along side the water supply line (not my work). The previous install was grossly inadequate and dangerous. Shipping time was reasonable, price was right, and I feel that I got my money's worth. This wire is good for its intended purpose and I would recommend it. December 22, 2015
Rated 5.0 out of 5.0 by Solid Wire. Super Fast Shipping. Super fast shipping. When I ordered, the delivery time was 2-3 weeks. Received the wire within 3 days. It arrived so fast that I overlooked it sitting in front of the house for an entire day (wasn't expecting it that fast)! I think I ordered on a Monday night and it was at my home by Thursday. Used this wire to power a sub-panel for a detached office off of the main dwelling. Needed 240v. Wire provided two hots (both 2awg), one neutral (2awg), and one ground (4awg). Running it on a 70amp breaker on the main panel. Great wire. Great price (cheaper than running the direct burial copper option, even when using conduit). August 25, 2015
Rated 5.0 out of 5.0 by RV Electrical Service Install Fast delivery, good price. Much cheaper than I could find in local electrical supply houses. Worked perfectly for my application. June 24, 2014
  • 2016-07-27 T14:22:11.220-05:00
  • bvseo_lps, prod_bvrr, vn_prr_5.6
  • cp-1, bvpage1
  • co_hasreviews, tv_5, tr_5
  • loc_en_US, sid_202316368, prod, sort_default
1-5 of 5
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 109ms
  • REVIEWS, PRODUCT