Return this item within 90 days of purchase.
Get an answer now with AI
AI-generated from the text of manufacturer documentation. To verify or get additional information, please contact The Home Depot customer service.
The AFC Cable Systems 1/2 in. x 25 ft. Flexible Aluminum Conduit is made with high-grade galvanized aluminum alloy strips for added strength and durability. 1, 2 and 3 hour through-penetration fire systems. UL and CSA listed.
Product Length (ft.) | 25 ft |
|---|---|
Trade Size (in.) | 1/2 |
Conduit Type | Flexible |
|---|---|
Indoor/Outdoor | Indoor |
Material | Aluminum |
Metallic/Non-Metallic | Metallic |
Pack Size | 1 |
Product Weight (lb.) | 2.50 lb |
Returnable | 90-Day |
Certifications and Listings | CSA Listed, UL Listed |
|---|---|
Manufacturer Warranty | Contact Manufacturer |
1/2 x 25 ft. Flexible Aluminum Conduit. The National Electric Code Article 348 regulates how and where flexible conduit can be used. The code does not distinguish between interior and exterior, but between wet and dry locations. The code does not allow flexible conduit to be used in a wet location. A wet location in this instance would be defined as an area subject to saturation with water or in unprotected areas subject to weather.
Yes, just will need to purchase the correct size flex connector for the K/O size on your handy box. ie; 1/2"
Fill chart would be in the NEC handbook
Yes per the NEC code 350 . Suitable for wet location and connections for cabinets and wire outlets. Product must be secured 10" from box then every 18" per code.
Yes, use the 1/2" flex connectors avail at Home Depot
Hello Lox, I’m Chris from the Home Depot’s how-to Community. Thank you for your question. You would use ½” flexible metal conduit connectors. These are common and easy to find. I am not sure what you mean by “standard” fittings, but connectors for thin metal emt conduit or ridged conduit will not work. I hope this helps, Chris. .
Bend the flex by hand, it will separate, use some standard diagonal wire cutters or tin snips. I've used that method for years
There are two options for cutting flex conduit. You can use a hacksaw, but be sure to file any sharp edges so you do not knick the building wire when fishing through the armor. The second option is using a cable cutter and I attached two cutters that Home Depot stocks: http://www.homedepot.com/p/Klein-Tools-BX-and-Armored-Cable-Cutter-53725/203872308 http://www.homedepot.com/p/Ideal-Sir-Nickless-Armored-Cable-Cutter-35-782/203761573?MERCH=REC-_-NavPLPHorizontal1_rr-_-NA-_-203761573-_-N
I use a vise and reciprocating saw. Works well.
Schedule 40 or PVC
We would recommend that you check the NEC Code for your area or with your local inspector, as codes and stadard vary by region in the Unisted States. Thank you.
Viewing 1-8 of 8