The Romex Type NM-B Copper Building Wire, featuring a patented SIMpull Cable Jacket, offers a hassle-free experience during installation, pulling, and stripping. Primarily intended for residential building wiring, it serves as an efficient branch circuit for switches and outlets. Suitable for above-ground installation in dry areas, this cable boasts a voltage rating of 600-volts, ensuring reliable performance. It's noteworthy that NM-B cable can be routed through air voids within masonry block or tile walls, as long as these walls remain free from wetness or dampness. Proudly crafted in the United States, it exemplifies quality and innovation in wiring solutions.
Total Wire Length (ft.): 125 ft
Total Wire Length (ft.) | 125 ft |
---|
Commercial/Residential | Residential | Conductor Material | Copper |
---|---|---|---|
Features | Heat Resistant, Jacketed | Gauge | 6 |
Grounded | Grounded | Indoor/Outdoor | Indoor |
Jacket Color | Black | Max Amps | 55 |
Number of Conductors | 2 | Returnable | 90-Day |
Stranded or Solid | Stranded | Voltage (v) | 600v |
Wet Location Use | Dry | Wire Cut Type | Pre-Cut Length |
Certifications and Listings | UL Listed | Manufacturer Warranty | NA |
---|
NO! Absolutely not!!! Type NM cable is interior cable only. Outdoors in conduit, or underground in conduit are not permitted and are an NEC violation.
#10 Bare Cu
As long as the wire is being installed to connect an outlet that is building-mounted to the panel building, yes. but if it runs underground, then no.
No! See Above
No only thhn
Yes, of course it can. By the way, THHN is wiring, and EMT is conduit, I don't know what that response means?
Yes
Yes, this 6/2 Romex SIMpull CU NM-B wire includes a ground wire.
This wire is rated for 600V and 55 amps. Whether or not it's suitable for your 220V welder depends on the welder's amperage requirements. If the welder draws more than 55 amps, this wire will be insufficient and could overheat, creating a fire hazard. Consult your welder's documentation for its amperage requirements to determine if this wire is appropriate. If you need further assistance, please consult a qualified electrician.