Type NM-B (nonmetallic-sheathed cable) may be used for both exposed and concealed work in normally dry locations at temperatures not to exceed 90 degree C (with-Ampacity limited to that for 60 degree C conductors) as specified in the NEC 1. NM-B cable is primarily used in residential wiring as branch circuits for outlets, switches and other loads. NM-B cable may be run in air voids of masonry block or tile walls where such walls are not subject to excessive moisture or dampness. Voltage rating for NM-B cable is 600-Volt.
Total Wire Length (ft.): 250 ft
Total Wire Length (ft.) | 250 ft |
|---|
Commercial/Residential | Residential |
|---|---|
Conductor Material | Copper |
Features | Heat Resistant, Jacketed |
Gauge | 12 |
Grounded | Grounded |
Indoor/Outdoor | Indoor |
Jacket Color | Yellow |
Max Amps | 20 |
Number of Conductors | 2 |
Returnable | 90-Day |
Stranded or Solid | Solid |
Voltage (v) | 600v |
Wet Location Use | Dry |
Wire Cut Type | Pre-Cut Length |
Certifications and Listings | UL Listed |
|---|
The maximum voltage for this NM cable is 600 volts.
Hi there, and thanks for reaching out! We'd like to hear more about your question, so that we can ensure that we're providing the most accurate answer. Please reach out to our dedicated team at consumersupport@southwire.com and we'll be happy to help.
Hi, happy to help! The 25 ft. 12/2 Solid Romex SIMpull CU NM-B W/G Wire has a total length of 25 feet. The approximate dimensions of the cable itself are 418 mils by 179 mils. If we can help in any other way, please reach out to us at consumersupport@southwire.com.
Great question! The "12/2" designation on this wire refers to its gauge and the number of current-carrying conductors inside the cable jacket. 12: This is the American Wire Gauge (AWG) size of the copper conductors, which is 12-gauge. 2: This indicates that there are two insulated current-carrying conductors inside the cable. Please let us know if you need help in any other way by contacting us at consumersupport@southwire.com.
About 90 pounds
Hello! Your inquiry is best handled by our specialized staff. Please email us at consumersupport@southwire.com, and we'll be happy to assist.
My AC is a 18000btu 220v 15A and not more than 25 feet from the source.
Hello, thank you for your question. This answer will require a more technical response. Please reach out to our technical team at cableteachsupport@southwire.com for a detailed explanation of your question.
Maybe! Check the data plate on the unit for the MCA. If the MCA is 16 or less than you can use this NM cable on either 120 or 240 volts. This cable is for indoor use only! DO NOT use this cable between the outdoor disconnect and the AC unit.
Please consult your RV dealer!
Hi there, and thanks for reaching out! We'd like to hear more about your question, so that we can ensure that we're providing the most accurate answer. Please reach out to our dedicated team at consumersupport@southwire.com and we'll be happy to help.
Hello! Your inquiry is best handled by our specialized staff. Please email us at consumersupport@southwire.com, and we'll be happy to assist.
Yes, you can! If it is a duplex 15A receptacle you can use a 20A circuit breaker. If it is a dedicated single 15A receptacle you must not use higher than a 15A circuit breaker!
Yes you absolutely can