#1 Home Improvement Retailer

Internet # 205338912

Model # L7224U1002

Store SKU # 821054

Store SO SKU #218061

Universal Oil Water Boiler Aquastat Relay for Boilers with and without Tankless Coil

$244.48
Apply Now
Pay $219.48 after $25 OFF your total qualifying purchase upon opening a new card. 
Apply for a Home Depot Consumer Card
  • Helps control circulator, oil burner and boiler temperature
  • For boilers with with and without Tankless Hot Water Coils
  • Fits easily with improved terminal layout and multiple knockouts
  • View More Details

Free & Easy Returns In Store or Online

Return this item within 90 days of purchase.

Read Return Policy

Ask about this product

Get an answer now with AI

Magic Apron Assistant is an AI virtual assistant. By proceeding, you consent to the recording and use of your information by The Home Depot (and authorized third parties). More information

Product Details

About This Product

The L7224U Oil Electronic Aquastat Controller provides electronic temperature sensing in a UL limit-rated controller. It controls the circulator, oil burner and boiler temperature. It also provides status, LED diagnostic and EnviroCOM communication.

Highlights

  • Well mount, horizontal or vertical position, or flush mounted remote from the well
  • Low limit can be disengaged for cold start boilers
  • L7224U is "outdoor temperature reset" ready when connected to a Honeywell outdoor reset kit, this option is intended for all applications except for tankless coil systems for domestic hot water
  • Intended for professional installation only
  • 2012 DOE compliant
  • Click here for more information on Electronic Recycling Programs
  • Return Policy

Product Information

Internet # 205338912

Model # L7224U1002

Store SKU # 821054

Store SO SKU #218061

Specifications

Dimensions: H 7.125 in, W 4.25 in, D 2.625 in

Dimensions

Product Depth (in.)

2.625 in

Product Height (in.)

7.125 in

Product Width (in.)

4.25 in

Details

Accessory Type

Boiler

HVAC Product Type

HVAC Switch

Pack Size

1

Product Weight (lb.)

3.5 lb

Returnable

90-Day

Warranty / Certifications

Manufacturer Warranty

1 year

Questions & Answers

My boiler has the L7248C1030 which is obosolete is this L224U1002 a direct replacement? If not, do you know which one is?
ByNov 19, 2025
1 Answer | 
Answer This Question

It is very difficult to answer Honeywell/Resideo questions definitively. Especially if you are not on site. Controls sold to boiler manufacturers as OEM components will frequently have unique model numbers, typically the last four digits referred to as the back up number. Typically, the exact model number you are trying to replace is only available from the boiler manufacturer as a replacement part. For example, based on a Google search is suspect your control came off a boiler produced by Peerless. To know if anything is unique about that control you would need to contact the boiler manufacturer. They will know about the operation cascade of that specific boiler based on the model and serial number. This universal triple acting aqua stat has a high limit, low limit and (circulator) relay. The low limit can be turned on or off, so it will work on cold start boiler or ones with tankless coil. The relay can be used to operate a single circulator or act as an end switch in a system that has multiple circulators or zone valves. In the years this universal control has been available I have not run into a residential forced hot water oil fired boiler where I have not been able to use it and to configure it to work as a replacement for the control on the boiler. But every hydronic heating system is different, so to do this you need a working understanding of the system’s wiring logic. If not, you should leave it to a local qualified licensed professional. So, is it a direct replacement? No. I would consider a “direct replacement” to be the same in every way. This control is a universal control that requires experience and knowledge to be configured correctly and integrated into the system.

By|Nov 19, 2025


    Is this a direct replacement for the triple aquastat Honeywell l8124a 1155, my oil furnace also provides hot water for showering & sinks so I need the circulator signal (C1/C2) on it.
    ByOct 29, 2025
    0 Answer | 
    Answer This Question

    Can the the well sensor be extended?
    ByDec 14, 2024
    1 Answer | 
    Answer This Question

    If you scroll down the Home Depot product listing page you will come to a section entitled Product Details. If you expand that section, there are PDFs of the product documents. If you open the specification sheet you will find table 2 which lists the different part numbers for sensor probes in the following lengths which can be ordered separately. 12”,18”,24”,36”,48”

    By|Dec 17, 2024


      Does this replacement come with a guarantee? My oil supplier company is charging me $960 for the part plus $145 for a guarantee of a year. Pls advise. Thank you.
      ByDec 15, 2023
      1 Answer | 
      Answer This Question

      Resideo provides a one-year warranty on this and similar controls

      By|Dec 18, 2023


        I have the very same one, am not getting very much hat water of and on, my boiler runs if I turn on the heat! So I know my boiler is working, How would I know if it?s my aquastat the one that is showing here, how would if that?s my problem with the wa
        ByJun 19, 2023
        1 Answer | 
        Answer This Question

        I am not sure I completely understand your question. If I go to a job site to diagnose a lack of hot water the first thing, I want to do is determine why the problem exists. It could be the aqua stat, but it could just as likely be one of the other system components. As to which one I can’t tell you because I do not know your system, and every system is different. You are welcome to give me a call and we can have a conversation about your specific system. I have done this for a long time and may be able to send you in the right direction. Aqua stats typically just fail, and the system stops working altogether. It would not be typical for them to create the problem you describe. It could happen but I doubt it. As to replacing an aqua stat, you can go by the model number or cross it to one that does the same thing. But that requires an understanding of the total system. Chris 978 651 3301

        By|Jun 20, 2023


          Does the L7224U-1002 aquastat have a place where I can connect a "C" wire from a wifi thermostat?
          ByDec 26, 2022
          1 Answer | 
          Answer This Question

          Scroll down the product listing page to the area entitled Product Details where you will find PDF’s of product documents. If you open up the specification sheet you will find traditional two wire thermostat wiring on page 8. I believe page 9 covers what you are looking for. Depending on what thermostat you are using you may want to give Honeywell now known as Resideo a call. I know people who have been able to get some advanced thermostats to work and I know others that have had to resort to using a device called a common maker to simulate a common.

          By|Dec 27, 2022


            Would this be item work as a replacement for my Electronic Aquastat L7224 / L7248 ?
            ByDec 24, 2022
            1 Answer | 
            Answer This Question

            Without looking at the specific boiler and system in question it is hard to be definitive. However as a general rule this universal triple acting aqua stat is a good replacement for most oil boiler double and triple acting aqua stats.

            By|Dec 27, 2022


              Hello, Is this the updated parts number that replaces the Discontinued Honeywell L7224c-1004 model?
              ByNov 1, 2022
              1 Answer | 
              Answer This Question

              No this aqua stat was not specifically manufactured to be the direct replacement of the number you reference. Although it could be used as a suitable replacement. I cannot give you a definitive answer as I don’t know what boiler you have and even you did I would need to be on site. Allow me to explain as it may help. The L7224 in the beginning of the long model number indicates the series and what this is; an aqua-stat. So to that extent they are the same. The C1004 also called the backup number indicates the way the control was configured. My guess is that this control was configured for a specific boiler manufacturer. Based on my searches I would assume Peerless. Therefore the connections and orientation have been designed to be what that manufacture wanted. This new control has a backup number of U1002. The “U” designates universal. This control is designed to replace many. It has functions that can be turned on and off so it can be configured in the field to work in many situations. I am confident it has the capability to replace your control. But it will not be exactly the same. The terminals may be in different locations and be indicated differently. It is important that you have a working knowledge of the logic designed into the wiring schematic so you can wire it correctly. Also that that you read and understand the instructions so that you can set the control parameters correctly so that it performs the same functions as the control you are replacing. For example you need to set the high limit temperature, set the low limit temperature or possibly shut off the low limit if this is a cold start system, etc.

              By|Nov 1, 2022


                Viewing 1-8 of 16

                Customer Reviews

                4.2 out of 5

                • 4.2 out of 16 reviews
                • 67% recommend this product
                Filter by:
                Showing 1-10 of 16 reviews
                This customer chose to rate the product and not provide text.
                by
                • Verified Purchase
                This customer chose to rate the product and not provide text.
                by
                • Verified Purchase
                Works as a replacement for older model, location of the wiring connectors is a bit annoying on the new one
                by
                • Verified Purchase
                This aquastat is easy to install, replacing an older model. Just wire one at a time and then you can adjust boiler settings to suit your needs. Using a outdoor reset module helps with keeping the house warm while saving energy.
                by
                • Verified Purchase
                Was cheaper than the OEM and works like a charm.
                by
                • Verified Purchase
                Cheaper replacement for old aquastat
                by
                • Verified Purchase
                Came on time-box was well packed- easy install...
                Came on time-box was well packed- easy install
                by
                • Verified Purchase
                Replaced older mech relay aquastat
                Ordered this to have on hand as I have 2 boilers with the older style Honeywell auquastats... had some boiler issues I was dealing /chasing down so I installed this .. install was easy, setup was easy ... has been running fine for over 6 months now... I do not think the old aquastat was the problem, it seemed to be related more to a faulty connection but I left this new Aquastat in place ... the older one may be the original and over 15 years old ... I see no future in buying the older style Aquastats as this works fine, completely electronic and is cheaper than buying the old style Honeywell which though in stock at HD at my store are more than $100 in cost compared to this electronic model .Honeywell L7224U-1002 Universal Electronic Oil Aquastat .. I have already upgraded all my old Honeywell boiler controls with Honeywell R7284U-1004 Electronic Oil Primary I don't mind spending >$100 less for an upgraded IMO more economical, reliable assy, as it is an electronic not electromechanical design... the only problem I have is why is this not in stock at my store ... I had to order this Honeywell L7224U-1002 Universal Electronic Oil Aquastat and have it delivered
                by
                  • Recommended
                  I'm not sure about the life expectancy of an aquastat...
                  I'm not sure about the life expectancy of an aquastat however I Replaced a 9 yr old (L8151c). This was a relatively quick swap and programming was easier than I expected.
                  by
                  • Verified Purchase
                  Works great, easy to install....
                  Works great, easy to install.
                  by
                  • Verified Purchase
                  Showing 1-10 of 16 reviews