Specially designed for easy installation, Eaton's BR 1-in. loadcenters house the branch circuit breakers and the wiring required to distribute power to individual circuits. They serve as main breaker for service entrances or as main lug when adding circuits to existing service. The main breaker protects the entire panel and can be used as a service disconnect. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets.

Dimensions: H 3.88 in, W 14.31 in, D 23 in
Product Depth (in.) | 23 in |
|---|---|
Product Height (in.) | 3.88 in |
Product Width (in.) | 14.31 in |
Breaker Box Type | Main Breaker Panel |
|---|---|
Connection Type | Neutral |
Electrical Product Type | Load Center and Breaker Kit |
Included | Cover |
Indoor/Outdoor | Indoor |
Maximum Amperage (A) | 100 A |
Mounting Type | Flush, Surface |
NEMA Configuration | NEMA 1 |
Number of Circuits | 40 |
Number of Pieces | 4 |
Number of Spaces | 20 |
Phase Type | 1 Phase |
Product Weight (lb.) | 22.85 lb |
Returnable | 90-Day |
Series Type | BR |
Voltage (V) | 120/240 V |
Certifications and Listings | UL Listed |
|---|---|
Manufacturer Warranty | 10 Year |
Hi, the wire range for the main breaker is #4–1/0. If you have further questions, please contact our technical support team at 877-386-2273 opt 2 opt 3 opt 1.
Hi, this value pack will include the 100A main breaker as well as (2) single pole 20A breakers (BR120) and (1) 2 pole 30A breaker (BR230). If you have further questions, please contact our technical support team at 877-386-2273 opt 2 opt 3 opt 1.
Hi, this loadcenter can be rotated 180 degrees and bottom fed with the main breaker at the bottom. If you have further questions, please contact our technical support team at 877-386-2273 opt 2 opt 3 opt 1.
yes knockouts are available for 2" and'[2 1/2'] but main breakeer and feeders must land on top of the sub panel but can enter from bottom
Hi, this loadcenter can be used as a sub panel. If you have further questions, please contact our technical support team at 877-386-2273 opt 2 opt 3 opt 1.
Hi, this panel does not include a hold-down kit for the main breaker, as it is specifically designed and labeled as a main breaker panel. Additionally, since this is a 20-space loadcenter, the bus stabs have been removed from the top space adjacent to the main breaker. As a result, no additional breakers beyond the 20 designated spaces can be installed. If you have further questions, please contact our technical support team at 877-386-2273 opt 2 opt 3 opt 1.
Hello, we would recommend checking with the manufacturer of the surge protector to confirm compatibility. Should you require further assistance, please reach out to our technical support team by calling 877-386-2273, selecting options 2, 3, and 1, or by emailing TRC@Eaton.com.