Top Rated

Return this item within 90 days of purchase.
Get an answer now with AI
AI-generated from the text of manufacturer documentation. To verify or get additional information, please contact The Home Depot customer service.
This 60 Amp GFCI Spa Panel has a G90 galvanized steel construction for superior corrosion protection, intended for outdoor use with spas, hot tubs, water heaters and swimming pools. The GFCI disconnect provides a convenient low-cost way to satisfy NEC requirements. The NEMA 3R design insures a safe, weather-tight installation for residential and light-commercial applications.
Product Depth (in.) | 4 in |
|---|---|
Product Width (in.) | 8.5 in |
Disconnect Type | Spa/Hot Tub Disconnect |
|---|---|
Indoor/Outdoor | Outdoor |
Maximum Amperage (A) | 125 A |
Maximum Wattage (W) | 0 W |
NEMA Configuration | NEMA 3R |
Number of Circuits | 8 |
Number of Spaces | 4 |
Phase Type | 1 Phase |
Product Weight (lb.) | 8.04 lb |
Returnable | 90-Day |
Voltage (V) | 240 V |
Certifications and Listings | ANSI Certified, UL Listed |
|---|---|
Manufacturer Warranty | One year warranty from first use |
General Electric
Yes, this spa panel includes a 60 Amp, 2-pole, 240V GFCI breaker. It is designed for outdoor use with spas, hot tubs, and other similar applications.
GE
It is a GE breaker and it does have a trip button. Be careful about removing it and installing it a different GE panel however. I have found it will not fit in allot of GE panels due to the neutral bus being right behind the breaker lugs.
Midwest Electrical Products is a GE company and uses only GE circuit breakers in their products. Yes, the GE 60 amp GFCI circuit breaker has a test button.
Yes, it has a test button. Perfect for our installation.
I know the label says use GE. I bought a 15 amp GE to add to it and the breaker fit perfectly.
Horrible product. You will have to buy a whole new system and you’re better off just replacing it with a different one from another company. Home Depot stopped selling these for a reason.
You can just replace the breaker. Buying just the breaker alone is sometimes more expensive than buying the whole spa panel and discarding the enclosure. Just check current pricing. You can buy these spa panels in 50 or 60 amp.
Yes, since the MLO panel is rated at 125 amps you can just replace the breaker with a new GE Type THQL 60 amp GFCI breaker. I think you will find that a new breaker costs more than the new Midwest 60 amp spa panel so I suggest you buy the new 60 amp spa panel and remove the 60 amp GFCI breaker and install it in your existing spa panel. Save the new panel box for future use.
Any GE THQL 2 pole GFCI breaker will fit. It may be cheaper to just buy the whole spa panel. Check current pricing.
A replacement GE 60 amp GFCI breaker will cost significantly more than buying a new spa panel. Buy a new spa panel and use the GFCI breaker as a replacement in your existing Midwest spa panel. OR..........take the bad GFCI breaker to a GE distributor (not retailer like HD or Lowes) for a warranty replacement.
From what I can remember when I installed it for a customer. On the left hand side one 3/4 KO. In the middle was three sizes 3/4, 1", 1 1/2". On the right side 2 sizes 3/4", 1". If there isn't enough you have plenty of room to make your own size KO.
On the bottom of the box there is 1 - 1/2" KO; 2 concentric KOs of 1/2",3/4",1"; 1 concentric KO of 3/4", 1", 1 1/4", 1 1/2".
There are 3 concentric knock outs on the bottom of the enclosure as well as a possible hub location on the top. the largest KO is a 1" I believe with the other 2 going up to 3/4
3 on the bottom up to 1 inch
You may be able to fit a seimens breaker in this panel but it is a code violation because it is not listed for a seimens breaker.
Yes, there are several breakers that will fit in this panel.
No, Midwest Electric Products is a GE company and only UL Listed for use with GE circuit breakers. To use a Siemens breaker in this disconnect would be a code violation.
Viewing 1-8 of 42