Internet #206517828

Model # RT110

Store SKU #673714

Store SO SKU #1001572316

0092644690266

Receptacle Outlet Tester

  • 110/125 VAC tester allows to detect wiring problems in receptacle
  • Tester with lighting sequence, indicates wiring correct condition
  • Also indicates open ground, reverse polarity and other conditions
store icon Loading Buying Options...
package icon Loading Buying Options...
Sorry, but we ran into issues loading these options. Please try refreshing.

Frequently Bought Together

Frequently Bought Together

Product Overview

  • 110/125 VAC tester allows to detect wiring problems in receptacle
  • Tester with lighting sequence, indicates wiring correct condition
  • Also indicates open ground, reverse polarity and other conditions
Klein Tools Receptacle Tester detects the most common wiring problems in standard receptacles. Conditions indicated: wiring correct, open ground, reverse polarity, open hot, open neutral, hot/ground reversed. Conditions not indicated: quality of ground, multiple hot wires and combinations of defects, reversal of grounded and grounding conductors.
  • Conforms to UL standard 1436, Certified to CSA standard C22.2 #160
  • Operating temperature: 32 Degrees F to 140 Degrees F (0 Degrees C to 40 Degrees C)
  • Built to endure a 6.6 ft. (2 m) drop
  • Light sequence indicates correct/incorrect wiring
  • Nominal voltage: 110/125-Volt AC at 50/60Hz in 3-wire outlet
  • Click here for more information on Electronic Recycling Programs
  • California residents see Prop 65 WARNINGS

Product Overview

  • 110/125 VAC tester allows to detect wiring problems in receptacle
  • Tester with lighting sequence, indicates wiring correct condition
  • Also indicates open ground, reverse polarity and other conditions
Model #: RT110
Sku #: 673714
Internet #: 206517828

Klein Tools Receptacle Tester detects the most common wiring problems in standard receptacles. Conditions indicated: wiring correct, open ground, reverse polarity, open hot, open neutral, hot/ground reversed. Conditions not indicated: quality of ground, multiple hot wires and combinations of defects, reversal of grounded and grounding conductors.

  • Conforms to UL standard 1436, Certified to CSA standard C22.2 #160
  • Operating temperature: 32 Degrees F to 140 Degrees F (0 Degrees C to 40 Degrees C)
  • Built to endure a 6.6 ft. (2 m) drop
  • Light sequence indicates correct/incorrect wiring
  • Nominal voltage: 110/125-Volt AC at 50/60Hz in 3-wire outlet
  • Click here for more information on Electronic Recycling Programs
  • California residents see Prop 65 WARNINGS

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Key Features

Product Overview
Key Features
  • 110/125 VAC tester allows to detect wiring problems in receptacle
  • Tester with lighting sequence, indicates wiring correct condition
  • Also indicates open ground, reverse polarity and other conditions
Klein Tools Receptacle Tester detects the most common wiring problems in standard receptacles. Conditions indicated: wiring correct, open ground, reverse polarity, open hot, open neutral, hot/ground reversed. Conditions not indicated: quality of ground, multiple hot wires and combinations of defects, reversal of grounded and grounding conductors.
  • Conforms to UL standard 1436, Certified to CSA standard C22.2 #160
  • Operating temperature: 32 Degrees F to 140 Degrees F (0 Degrees C to 40 Degrees C)
  • Built to endure a 6.6 ft. (2 m) drop
  • Light sequence indicates correct/incorrect wiring
  • Nominal voltage: 110/125-Volt AC at 50/60Hz in 3-wire outlet
  • Click here for more information on Electronic Recycling Programs
  • California residents see Prop 65 WARNINGS

Product Overview

  • 110/125 VAC tester allows to detect wiring problems in receptacle
  • Tester with lighting sequence, indicates wiring correct condition
  • Also indicates open ground, reverse polarity and other conditions
Model #: RT110
Sku #: 673714
Internet #: 206517828

Klein Tools Receptacle Tester detects the most common wiring problems in standard receptacles. Conditions indicated: wiring correct, open ground, reverse polarity, open hot, open neutral, hot/ground reversed. Conditions not indicated: quality of ground, multiple hot wires and combinations of defects, reversal of grounded and grounding conductors.

  • Conforms to UL standard 1436, Certified to CSA standard C22.2 #160
  • Operating temperature: 32 Degrees F to 140 Degrees F (0 Degrees C to 40 Degrees C)
  • Built to endure a 6.6 ft. (2 m) drop
  • Light sequence indicates correct/incorrect wiring
  • Nominal voltage: 110/125-Volt AC at 50/60Hz in 3-wire outlet
  • Click here for more information on Electronic Recycling Programs
  • California residents see Prop 65 WARNINGS

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar

Compare Similar Products
Brand Gardner Bender Klein Tools Commercial Electric Gardner Bender
Name 120 VAC Outlet Tester Receptacle Outlet Tester Outlet Tester Outlet and GFCI Tester
Price
$5.46
See Lower Price in Cart
$6.74
$7.99
Ratings (85) (29) (103) (102)
Test Meter Type Specialty Meter/Tester Specialty Meter/Tester Specialty Meter/Tester Specialty Meter/Tester
View Product View Product View Product View Product

Specifications

Dimensions

Product Depth (in.)
1
Product Height (in.)
3
Product Width (in.)
1.69

Details

Control Type
Manual/Analog
Display Type
LED
Electrical Tools Features
No Additional Features
Measures/Detects
Polarity
Product Weight (lb.)
.08lb
Returnable
90-Day
Test Meter Type
Specialty Meter/Tester
Tools Product Type
Test Meter

Warranty / Certifications

Manufacturer Warranty
Please refer to the attached warranty document in the Product Overview section above under Info & Guides.

Specifications

Dimensions

Product Depth (in.)
1
Product Height (in.)
3
Product Width (in.)
1.69

Details

Control Type
Manual/Analog
Display Type
LED
Electrical Tools Features
No Additional Features
Measures/Detects
Polarity
Product Weight (lb.)
.08lb
Returnable
90-Day
Test Meter Type
Specialty Meter/Tester
Tools Product Type
Test Meter

Warranty / Certifications

Manufacturer Warranty
Please refer to the attached warranty document in the Product Overview section above under Info & Guides.

Questions & Answers

Will it definitely determine whether or not an outlet is grounded? I replaced an old two hole out...

Will it definitely determine whether or not an outlet is grounded? I replaced an old two hole outlet with a three hole and it read “correct” (two right lights of bottom row lit up). Can I assume it”’s grounded?
Asked by: Steve
It will let you know whether a receptacle is grounded or not. Of course if you haven't grounded the new outlet it will show that it's not grounded.
Answered by: RichK
Date published: 2019-07-02

What is mean open ground?

What can I do ?
Asked by: Balbli
UNGROUNDED OR OPEN GROUND OUTLETS Ungrounded outlets are a safety hazard and are in violation of the building and national wiring codes. They need be made safe immediately. Newer Wiring In homes where all the outlets were installed with a ground, any failure of the ground must be corrected by replacing the failing outlet, or replacing and/or reconnecting the ground wire. In many cases the open ground on one outlet is the result of a disconnected wire at another outlet. A wire disconnected from one outlet will disconnect the ground service from all the outlets down line. Older Wiring In older homes the original wiring did not have ground wire connected to the outlets. These ungrounded outlets are easily distinguished by their two hole / slot configuration verses the newer grounded type of outlet that has three holes / slots. Ungrounded outlets that have two holes / slots used in a home that was originally wired in this manner and has not been rewired are considered acceptable. Where the Problem Begins The problems for the owners of older homes start when grounded type outlets are substituted for the ungrounded type without the necessary rewiring that adds a ground wire to the new three prong grounded type outlet. Grounded type (three hole / slot) outlets may not be substituted for ungrounded outlets unless a ground wire is connected. An exception to this rule is allowed by the National Electric Code, when the outlet is protected by a ground fault interrupter (GFI or GFCI). The Fixes There are two fixes available for those home owners who do not want to rewire the entire house. The first fix uses Ground Fault Interrupters. There are two types of GFI available, one takes the place of the regular circuit breaker in the load center. The second type that is available takes the place of the standard outlet and replaces it with a special GFI protected outlet. These are commonly used in the kitchens and bathrooms of newer homes. Most people know them for their black and red reset buttons. The second fix – In many older homes the outlet mounting box was grounded but the outlet was not, if this the case it is possible to use a jumper between the mounting box and the grounding screw on the new grounded type outlet. This type of ground may not be adequate for surge protectors. (see below) Surge Protectors A surge protector plugged into an ungrounded outlet will not operate as the manufacturer intended. When a large surge or spike hits, the surge protector uses the ground wire to take the "hit" away from the protected equipment and send it safely to ground. If the surge or spike is not sent to ground by the surge protector it will destroy the delicate electronics you were trying to protect. The warranty offered by the surge protectors manufacturer offer, is only valid if the surge protector is used in a properly grounded outlet.
Answered by: Uncle60
Date published: 2019-02-04
  • y_2019, m_11, d_7, h_9CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.13
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_2
  • loc_, sid_206517828, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 18ms
  • QUESTIONS, PRODUCT