Internet #202316470

Model # 55094321

Store SKU #610136

0032886046025

Southwire

3/4 in. x 25 ft. Ultratite Liquidtight Flexible Non-Metallic PVC Conduit

$ 23 37
Loading Options
store icon Loading Buying Options...
package icon Loading Buying Options...
Sorry, but we ran into issues loading these options. Please try refreshing.

Frequently Bought Together

Frequently Bought Together

+
+

Product Overview

The Southwire Ultratite 3/4 in. x 25 ft. Nonmetallic Liquid-Tight Conduit is for use in applications requiring movement, crossover connections or tight bends. CSA- and UL listed. Can be used in agricultural buildings under exposed installations or concealed installations.
  • Use to install and help protect electrical conductors in circuits rated 600 volts nominal or less
  • Made with a spiral of rigid PVC reinforcement embedded within a flexible PVC wall
  • Crush-resistant construction
  • Use in lengths longer than 6 ft.
  • For use in applications requiring movement, crossover connections or tight bends
  • Suitable for use with motor circuits for conductors of motor feeders, branch circuits and control circuits
  • Ideal for use in conditions of installation, operation or maintenance where flexibility is required, or when the protection from liquids, vapors, solids and weather is needed
  • Note: Product may vary by store.

Product Overview

Model #: 55094321
Sku #: 610136
Internet #: 202316470

The Southwire Ultratite 3/4 in. x 25 ft. Nonmetallic Liquid-Tight Conduit is for use in applications requiring movement, crossover connections or tight bends. CSA- and UL listed. Can be used in agricultural buildings under exposed installations or concealed installations.

  • Use to install and help protect electrical conductors in circuits rated 600 volts nominal or less
  • Made with a spiral of rigid PVC reinforcement embedded within a flexible PVC wall
  • Crush-resistant construction
  • Use in lengths longer than 6 ft.
  • For use in applications requiring movement, crossover connections or tight bends
  • Suitable for use with motor circuits for conductors of motor feeders, branch circuits and control circuits
  • Ideal for use in conditions of installation, operation or maintenance where flexibility is required, or when the protection from liquids, vapors, solids and weather is needed
  • Note: Product may vary by store.

Key Features

Product Overview
Key Features
The Southwire Ultratite 3/4 in. x 25 ft. Nonmetallic Liquid-Tight Conduit is for use in applications requiring movement, crossover connections or tight bends. CSA- and UL listed. Can be used in agricultural buildings under exposed installations or concealed installations.
  • Use to install and help protect electrical conductors in circuits rated 600 volts nominal or less
  • Made with a spiral of rigid PVC reinforcement embedded within a flexible PVC wall
  • Crush-resistant construction
  • Use in lengths longer than 6 ft.
  • For use in applications requiring movement, crossover connections or tight bends
  • Suitable for use with motor circuits for conductors of motor feeders, branch circuits and control circuits
  • Ideal for use in conditions of installation, operation or maintenance where flexibility is required, or when the protection from liquids, vapors, solids and weather is needed
  • Note: Product may vary by store.

Product Overview

Model #: 55094321
Sku #: 610136
Internet #: 202316470

The Southwire Ultratite 3/4 in. x 25 ft. Nonmetallic Liquid-Tight Conduit is for use in applications requiring movement, crossover connections or tight bends. CSA- and UL listed. Can be used in agricultural buildings under exposed installations or concealed installations.

  • Use to install and help protect electrical conductors in circuits rated 600 volts nominal or less
  • Made with a spiral of rigid PVC reinforcement embedded within a flexible PVC wall
  • Crush-resistant construction
  • Use in lengths longer than 6 ft.
  • For use in applications requiring movement, crossover connections or tight bends
  • Suitable for use with motor circuits for conductors of motor feeders, branch circuits and control circuits
  • Ideal for use in conditions of installation, operation or maintenance where flexibility is required, or when the protection from liquids, vapors, solids and weather is needed
  • Note: Product may vary by store.

Compare Similar

Compare Similar Products
Brand JM eagle Southwire Carlon Southwire
Name 1-1/2 in. x 10 ft. PVC Schedule 40 Conduit 3/4 in. x 25 ft. Ultratite Liquidtight Flexible Non-Metallic PVC Conduit 3/4 in. x 100 ft. Electrical Nonmetallic Tubing Conduit Coil, Blue 1/2 in. x 100 ft. Ultratite Liquidtight Flexible Non-Metallic PVC Conduit
Price
$7.00
$23.37
$42.35 /roll
$46.63
Ratings (44) (90) (28) (52)
Length 10 ft. 25 ft. 100 ft. 100 ft.
Conduit type Nonmetallic Nonmetallic Nonmetallic Nonmetallic
Material PVC PVC PVC PVC
Size (in.) 1-1/2 3/4 3/4 1/2
View Product View Product View Product View Product

Specifications

Dimensions

Length
25 ft.
Nominal inside diameter (in.)
0.820
Nominal outside diameter (in.)
1.030
Product Depth (in.)
13.13
Product Height (in.)
6.25
Product Length (ft.)
25
Product Width (in.)
13.13
Size (in.)
3/4
Trade Size (in.)
3/4

Details

Color Family
Gray
Conduit type
Nonmetallic
Direct Burial
Yes
Electrical Product Type
Conduit
Flexible
Yes
Material
PVC
Package Quantity
1
Product Weight (lb.)
18.00lb
Returnable
90-Day

Warranty / Certifications

Manufacturer Warranty
N/A

Specifications

Dimensions

Length
25 ft.
Nominal inside diameter (in.)
0.820
Nominal outside diameter (in.)
1.030
Product Depth (in.)
13.13
Product Height (in.)
6.25
Product Length (ft.)
25
Product Width (in.)
13.13
Size (in.)
3/4
Trade Size (in.)
3/4

Details

Color Family
Gray
Conduit type
Nonmetallic
Direct Burial
Yes
Electrical Product Type
Conduit
Flexible
Yes
Material
PVC
Package Quantity
1
Product Weight (lb.)
18.00lb
Returnable
90-Day

Warranty / Certifications

Manufacturer Warranty
N/A

Questions & Answers

Can this conduit be used outdoors? Is it UV protected?

I need to run a 200' piece of CAT 5 outdoors up a rock face, and need to provide some protection from abrasion. I am concerned if this product will hold up in the sunlight.
Asked by: ISPinNM
It will turn brown and hard as a rock in a few years depending on how much sunlight it receives and will start to crack open, recommend spraying or wrapping with something? Not sure what though.
Answered by: TheOne
Date published: 2018-12-13

I need to run two (2) 20a 120v circuits, buried. As I understand, cable is not permissible in bur...

I need to run two (2) 20a 120v circuits, buried. As I understand, cable is not permissible in buried conduit so I will be running 6 wires (2 hot, 2 neutral and 2 ground 12 gauge). Can they all go in one conduit, or does each ckt. have to be isolated in it's own conduit? And will I need 1/2", 3/4" or 1"?
Asked by: IslandHandyman
We ran 2 2/0 wires in 1" and it pulled fairy easily (for wire that's as fat as your pinky finger anyway). You can run all 6 wires in the same conduit, just make sure to mark the ends on wires that are the same color to minimize confusion. Neutral and ground won't matter much but your hots definitely will. I would also recommend going with the largest diameter that's practical in case you ever need to pull new wire for a repair or adding a circuit in the future because once it's buried, it's buried!
Answered by: govtmule
Date published: 2019-02-19

Outdoor Use

Is this product, when used outdoors, rodent proof. Squirrels, Mice etc.
Asked by: AD2
No. Rodents sometimes chew on products containing PVC and this product is no exception.
Answered by: SouthwireCustomerService
Date published: 2019-02-19

Direct Burial in dirt

Can this product be buried directly in the earth for LV applications?
Asked by: jt
Yes, this product can be used for direct burial. The above advice is based upon the current edition of the National Electric Code (NEC). Free access to the latest version of the NEC is available online at www.nfpa.org/freeaccess. The NEC and local building codes regulate the types of wire and cable that can be used in specific electrical applications, as well as the manner of installation. Check your local building codes before you start any wiring and cable electrical project and be sure to obtain required permits. When your work is complete, always have it inspected for compliance with local codes to ensure that it has been safely installed.
Answered by: SouthwireCustomerService
Date published: 2019-02-19
  • y_2019, m_9, d_12, h_20CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.13
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_31
  • loc_, sid_202316470, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 16ms
  • QUESTIONS, PRODUCT

Customer Reviews

3/4 in. x 25 ft. Ultratite Liquidtight Flexible Non-Metallic PVC Conduit is rated 4.5 out of 5 by 89.
Rated 1 out of 5 by from I have made many online purchases over the years but... I have made many online purchases over the years but this was by far my worse experience. I received a small box with only half the 90 degree conduit fittings, none of the 20 straight conduit fittings and no 100 foot conduit which would not have fit in the box sent. I called Visa to dispute charges.
Date published: 2019-08-20
Rated 3 out of 5 by from I was using this around some corners and had trouble... I was using this around some corners and had trouble getting it to stay. If you need it for anything short length it is very much “spring loaded” and will lift itself out of gravel which makes it harder to bury it to a proper depth and also makes it hard to slide wire through. Get prewired.
Date published: 2019-08-13
Rated 5 out of 5 by from The liquid-tight flexible conduit worked perfectly for my installation of... The liquid-tight flexible conduit worked perfectly for my installation of a remote devise using 10 gauge wire. Always install wire into the conduit before pushing the conduit into a straight or 90 degree fitting as once the conduit is installed into the fitting it can not be removed. Biff
Date published: 2019-07-30
Rated 5 out of 5 by from This conduit with available straight & 90 degree connectors make... This conduit with available straight & 90 degree connectors make a watertight connection. There is even an O ring where the connectors attach to the electrical box.
Date published: 2019-08-07
Rated 3 out of 5 by from I ordered this in a 150 foot roll because I wanted one 150 foot piece . It come in a 50 and a 100... I ordered this in a 150 foot roll because I wanted one 150 foot piece . It come in a 50 and a 100 Foot roll. . Had to slice it together.
Date published: 2019-08-06
Rated 5 out of 5 by from Does the job of protecting the wires, and making the... Does the job of protecting the wires, and making the installation look neat.
Date published: 2019-07-16
Rated 5 out of 5 by from It works for my project. No issues! Right on schedule on delivery. It works for my project. No issues! Right on schedule on delivery.
Date published: 2019-07-23
Rated 5 out of 5 by from Made a nice whip for ac condenser power cord. ... Made a nice whip for ac condenser power cord.
Date published: 2019-06-18
  • y_2019, m_9, d_12, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.13
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_89
  • loc_, sid_202316470, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 24ms
  • REVIEWS, PRODUCT