The Square D by Schneider Electric Ground Bar Kit is an important accessory in your home or business electrical load center. The aluminum 15 Terminal Ground Bar Kit is used in Square D load centers, CSED devices and NQOD and NF panel boards. The kit has 15 terminals, each accepting (1) #14 - #4 copper wire or (1) #12 - #4 aluminum wire, or (2) #14 - #12 copper wire or (2) #12 - #10 aluminum wire.
Product Depth (in.) | 1.32 in |
|---|---|
Product Width (in.) | 0.31 in |
Number of Terminals | 15 |
|---|---|
Product Weight (lb.) | 0.16 lb |
Returnable | 90-Day |
Certifications and Listings | ANSI Certified, UL Listed |
|---|---|
Manufacturer Warranty | Square D warrants equipment manufactured by it and sold through authorized sales channels to be free from defects in materials and workmanship for eighteen (18) months from date of invoice by Square D or its authorized sales channel. |
Hi Arthur, PK23GTACP is 9.36 inches long. Warm Regards, Schneider Electric Customer Care.
Hellon Ethan. No, PK3GTA1CP will not accept 1/0 wire. The only wire sizes it will accept are (1) #14 - #4 CU / AL, (2 or 3) #14 CU wires, (2 or 3) # 12 CU / AL wires, (2 or 3) #10 CU / AL wires, Warm regards. Schneider Electric Customer Care
Hello sphh. Sharing neutrals with grounds and visa versa, depends upon the application in which the load center is used. If the load center is installed as the point of Service Entrance, the neutral is field bonded to the enclosure so any unused neutral / ground terminals may be used to terminate either wires. They are already commonly connected as the Service Entrance wiring standards dictate for load centers and panelboards. If the load center is installed as a sub-panel, the neutral is isolated and not bonded to the enclosure's ground therefore all branch ground wires must be terminated into an equipment ground bar and neutrals to the neutral bar only. Warm regards. Schneider Electric Customer Care
Hello sphh. Sharing neutrals with grounds and visa versa, depends upon the application in which the load center is used. If the load center is installed as the point of Service Entrance, the neutral is field bonded to the enclosure so any unused neutral / ground terminals may be used to terminate either wires. They are already commonly connected as the Service Entrance wiring standards dictate for load centers and panelboards. If the load center is installed as a sub-panel, the neutral is isolated and not bonded to the enclosure's ground therefore all branch ground wires must be terminated into an equipment ground bar and neutrals to the neutral bar only. Warm regards. Schneider Electric Customer Care
Hi Gav5, Each of the load center enclosures will have 3 separate ground bar mounting locations inside the enclosure, one location on the left side, one on the right side, and one at the bottom of the interior. Each ground bar mounting location will be marked with a stamped ground symbol and will have 'anti-turn nubs' at that location in the enclosure and a mounting hole where the PK ground bar will be mounted. Warm Regards, Schneider Electric Customer Care.
Hello Anthony. PK23GTACP is compatible with HOM2040L125PGC. Please make sure the PK23GTACP is installed on the proper location in the HOM2040L125PGC. These locations should have the ground symbol. Also, PK23GTACP will come with #8-32 x 0.68in Pan Head(#2 Phillips drive) Thread Forming screw. Since it is a thread forming screw it is a little bit smaller than the mounting hole. Warm regards. Schneider Electric Customer Care
Hello Mike. In order to help you we need to know more information about your experience with this product. You can contact us anytime using our chat live https://www.se.com/us/en/work/support/customer-care/contact-schneider-electric.jsp where an agent will be able to give you further assistance on this matter. Warm regards. Schneider Electric Customer Care
Hi Metoo, This uses an 8-32 mounting screw. Warm Regards, Schneider Electric Customer Care.