Return this item within 90 days of purchase.
Get an answer now with AI
AI-generated from the text of manufacturer documentation. To verify or get additional information, please contact The Home Depot customer service.
The QO Surgebreaker Surge Protective Device is designed as a quick plug-on unit is compatible with Square D QO load centers and CSED devices. The SPD requires 2-pole spaces. This unit has 25,000 amp maximum surge capacity and has a 150 VAC line-to-ground maximum providing protection from electrical surges.


Product Depth (in.) | 2.6 in |
|---|---|
Product Width (in.) | 1.5 in |
Connection type | Breaker |
|---|---|
Joules | 930 |
Maximum Amperage (A) | 25000 A |
Returnable | 90-Day |
Certifications and Listings | ANSI Certified, CSA Listed, UL Listed |
|---|---|
Manufacturer Warranty | Square D warrants its QO Surge Breaker to be free from defects in material and workmanship under normal care and proper usage in a residential installation, for three years. |
Hello Tabbyf, In order to help you, we need to know more information about your experience with this product. We would like to encourage you to contact our Product Support at 888-778-2733 option 2, then 1, then 6 for surge protection where an agent will be able to give you further assistance on this matter. Warm regards. Schneider Electric Customer Care
Hello Chuck. The best option may vary depending on your personal preferences and the surge conditions in your location. Warm regards. Schneider Electric Customer Care
Hello Mewq. It was an engineering design decision to make the device completely black. However, it has the same indication light like the old design to tell the status of the SPD. Warm regards. Schneider Electric Customer Care
Hi SMRTech, It is not required, but it is a recommendation. The SPD requires two adjacent mounting spaces and should be installed as close to the main circuit breaker, or main lugs as possible. So that in an event of surges, it will be the SPD near the main breaker to absorb all the surges to avoid any leakage downstream. Warm regards. Schneider Electric Customer Care
Hello Paul, The QO2175SB can still be installed in a sub panel, it is actually recommended to have an SPD per panel. This is what we call the "cascaded protection". For more information, you can contact us anytime using our chat live https://www.se.com/us/en/work/support/customer-care/contact-schneider-electric.jsp where an agent will be able to give you further assistance on this matter. Warm regards. Schneider Electric Customer Care
Hello Dennis, This device is not designed or tested to fit on another manufacturer's equipment since it will void UL listings and the Warranty as well. Each manufacturer has it's own UL listings for their specific products based on their specific product line and their specific combination of products. Regards, Schneider Electric Customer Care
Pete, QO2175SB QO Surgebreaker - NON-plug-on neutral compatible securing up to a 22.5 kA surge current per phase. 3 Year Warranty - $10,000 limited downstream equipment protection. Warm regards. Schneider Electric Customer Care
Frank, Unfortunately No. Each manufacturer has it's own UL listings for their specific products based on their specific product line and their specific combination of products. Warm regards. Schneider Electric Customer Care
Viewing 1-8 of 72
4.8 out of 5