Model # QO2L30SCP

Internet #100157760

Store SKU #577286

Square D QO 30 Amp 2-Space 2-Circuit Indoor Main Lug Load Center
0047569804328

Square D

QO 30 Amp 2-Space 2-Circuit Indoor Main Lug Load Center

  • QO Interiors and Components provide time-tested reliability
  • Compatible with Square D QO standard circuit breakers
  • Surface mount indoor cover and aluminum bus bar included
$1428 /each
store icon Loading Buying Options...
package icon Loading Buying Options...
Sorry, but we ran into issues loading these options. Please try refreshing.

Frequently Bought Together

Product Overview

  • QO Interiors and Components provide time-tested reliability
  • Compatible with Square D QO standard circuit breakers
  • Surface mount indoor cover and aluminum bus bar included
The Square D QO 30 Amp 2-Space 2-Circuit Fixed Main Lugs Indoor Load Center is UL listed for residential, commercial and industrial power distribution. This load center is built with a rugged themoplastic interior and an aluminum bus bar plated for reliability. QO load centers are tested and listed only for QO circuit breakers. QO load centers are the "World's Finest" designed with industry leading features for flexible application. QO load centers include features engineered for fast installation and wire savings.
  • Includes a surface mount indoor cover
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Main feeders terminate from the top, feeders can enter from any direction, however, device cannot be rotated
  • Single phase
  • Rated 120/240 VAC and 10,000 AIR short circuit current rating
  • Surface mount device cover without a door
  • Thermoplastic interior is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • Learn More About Electrical Panels Here in our Buying Guide.

Product Overview

  • QO Interiors and Components provide time-tested reliability
  • Compatible with Square D QO standard circuit breakers
  • Surface mount indoor cover and aluminum bus bar included
Model #: QO2L30SCP
Sku #: 577286
Internet #: 100157760

The Square D QO 30 Amp 2-Space 2-Circuit Fixed Main Lugs Indoor Load Center is UL listed for residential, commercial and industrial power distribution. This load center is built with a rugged themoplastic interior and an aluminum bus bar plated for reliability. QO load centers are tested and listed only for QO circuit breakers. QO load centers are the "World's Finest" designed with industry leading features for flexible application. QO load centers include features engineered for fast installation and wire savings.

  • Includes a surface mount indoor cover
  • Accommodates plug-on secondary surge arrestor (sold separately)
  • Main feeders terminate from the top, feeders can enter from any direction, however, device cannot be rotated
  • Single phase
  • Rated 120/240 VAC and 10,000 AIR short circuit current rating
  • Surface mount device cover without a door
  • Thermoplastic interior is among the most rugged in the industry
  • Slot/square drive screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
  • Learn More About Electrical Panels Here in our Buying Guide.

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar

Price
$11.97 /each
$13.74 /each
$13.93 /each
$14.34 /each
$14.96 /each
$19.77 /each
$22.48 /each
$22.97 /each
$24.90 /each
Name PowerMark Gold 40 Amp 2-Space 4-Circuit Indoor Single-Phase Main Lug Circuit Breaker Panel QO 30 Amp 2-Space 2-Circuit Indoor Main Lug Load Center 60 Amp BR Type Main Lug Load Center Homeline 70 Amp 2-Space 4-Circuit Indoor Surface Mount Main Lug Load Center with Cover BR 70 Amp 2 Space 4 Circuit Indoor Main Lug Loadcenter Homeline 100 Amp 6-Space 12-Circuit Indoor Surface Mount Main Lug Load Center with Cover EQ 60 Amp 2-Space 4-Circuit Main Lug Flush Mount Load Center QO 100 Amp 6-Space 12-Circuit Indoor Main Lug Load Center Homeline 70 Amp 2-Space 4-Circuit Outdoor Main Lug Load Center
Brand Square D Eaton Square D Eaton Square D Siemens Square D Square D
Ratings (7) (6) (0) (8) (3) (13) (0) (1) (6)
Indoor/Outdoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Indoor Outdoor
Number of Phases 1 1 1 1 1 1 1 1 1
Mounting type Plug In Plug In Plug In Plug In Plug In Plug In Plug In Plug In Plug In
Maximum Amperage (amps) 40 30 60 70 70 100 60 100 70
Number of Spaces 2 2 2 2 2 6 2 6 2
View Product View Product View Product View Product View Product View Product View Product View Product View Product

Specifications

Dimensions

Load center depth (in.)
3
Load center height (in.)
6.72
Load center width (in.)
3.81

Details

Electrical Product Type
Main Lug/ Main Lug Kit
Indoor/Outdoor
Indoor
Load Center Type
Main Lug
Maximum Amperage (amps)
30
Mounting type
Plug In
Number of Phases
1
Number of Spaces
2
Product Weight (lb.)
2.1lb
Returnable
90-Day
Voltage (volts)
120/240

Warranty / Certifications

Certifications and Listings
1-UL Listed
Manufacturer Warranty
Square D warrants its QO branch circuit breakers to be free from defects in material and workmanship under normal care and proper usage in a residential installation, for the lifetime of the load center in which it is installed. QO brand load centers are also covered under the same lifetime warranty.

Specifications

Dimensions

Load center depth (in.)
3
Load center height (in.)
6.72
Load center width (in.)
3.81

Details

Electrical Product Type
Main Lug/ Main Lug Kit
Indoor/Outdoor
Indoor
Load Center Type
Main Lug
Maximum Amperage (amps)
30
Mounting type
Plug In
Number of Phases
1
Number of Spaces
2
Product Weight (lb.)
2.1lb
Returnable
90-Day
Voltage (volts)
120/240

Warranty / Certifications

Certifications and Listings
1-UL Listed
Manufacturer Warranty
Square D warrants its QO branch circuit breakers to be free from defects in material and workmanship under normal care and proper usage in a residential installation, for the lifetime of the load center in which it is installed. QO brand load centers are also covered under the same lifetime warranty.

Questions & Answers

can I use a 15 amp 20 amp tandem breaker in this box?

Asked by: irgo76
I am not sure what a 15 amp 20 amp tandem breaker is. Maybe you meant 15 amp or 20 amp tandem circuit breakers. You can use any QO compatible breaker and they will physically fit. I mounted 2 single space 15 amp tandem breakers in my box providing 4 individual output circuits and 2 individual input circuits. I do have 20 amp circuit breakers upstream feeding the 2 individual circuits. HOWEVER, now that I have researched this a little more, I am not sure that is code compliant. Customer service reply says you can't or should not do it. I presumed that the 30 amp rating is per circuit and Customer service replys don't nix the use of 10 ga 30 amp wire, so I don't see why one can not use 15 amp tandem breakers. I would suggest that if you want to use 20 amp tandem breakers, you should use a 30 amp breaker upstream on each of the 2 input circuits. Home Depot does have a 60 amp 2 space, 4 circuit breaker load center if you want to be absolutely sure you are code compliant. Be advised I am not a licensed electrician but I do have a degree in Electrical Engineering
Answered by: MCS
Date published: 2018-07-08

Could I install 2 QO120 breakers in this? I have a 10-2 w/gr romex feeding. Should I use a QO230 ...

Could I install 2 QO120 breakers in this? I have a 10-2 w/gr romex feeding. Should I use a QO230 or QO130 in main panel? Thanks.
Asked by: RustySpurr
With 10-2, you can only install 1 single pole circuit (line,neutral and ground), which means you can only utilize one of the slots for one breaker since the other slot won’t have power going to it. There are ways around this, but they aren’t to code and I wouldn’t recommend doing that.
Answered by: Adam
Date published: 2018-03-01

Could you flush mount this instead of surface mount

Asked by: Fk1977
Yes.
Answered by: Gord1980
Date published: 2018-06-13

I am bringing 10/2 with ground into the box and using 2 20 amp breakers in the box. Where do I p...

I am bringing 10/2 with ground into the box and using 2 20 amp breakers in the box. Where do I place the wire?
Asked by: al
there should be a "bonding" screw then the ground wire can go into the nuetral bar. Square D video - https://www.youtube.com/watch?v=6HGaRNBcADY Basically the nuetral bar gets "grounded" to the chassis and the chassis becomes ground/nuetral
Answered by: mitchstein
Date published: 2017-11-25
  • y_2018, m_8, d_19, h_16CST
  • bvseo_bulk, prod_bvqa, vn_bulk_2.0.8
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_14
  • loc_, sid_100157760, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING), SortEntry(order=BEST_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=POSITIVE_ANSWER_FEEDBACK_COUNT, direction=DESCENDING), SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 92ms
  • QUESTIONS, PRODUCT

Customer Reviews

QO 30 Amp 2-Space 2-Circuit Indoor Main Lug Load Center is rated 4.2 out of 5 by 6.
Rated 4 out of 5 by from This electrical box works good just a little to small. Hard to get all the wires and brakes in. This electrical box works good just a little to small. Hard to get all the wires and brakes in.
Date published: 2018-06-12
Rated 5 out of 5 by from works fine for a add on... works fine for a add on
Date published: 2018-07-16
Rated 4 out of 5 by from Worked well... Worked well
Date published: 2018-06-19
Rated 3 out of 5 by from I have been searching to no avail to find a breaker for this box! The two recommended breakers l... I have been searching to no avail to find a breaker for this box! The two recommended breakers listed do not fit this box. Any breaker with the two prongs intended to slide over a metal bar WILL NOT FIT THIS BOX. No where in the specs does it list a compatible breaker??? What is the big secret?
Date published: 2017-12-04
Rated 5 out of 5 by from perfect size and good quality, worth twice the price. perfect size and good quality, worth twice the price.
Date published: 2017-11-23
Rated 4 out of 5 by from I haven't installed yet. from what i see it will... I haven't installed yet. from what i see it will work fine. thank you.
Date published: 2017-08-29
  • y_2018, m_8, d_19, h_16
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.8
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_6
  • loc_, sid_100157760, prod, sort_[SortEntry(order=RELEVANCE, direction=DESCENDING)]
  • clientName_homedepot
  • bvseo_sdk, java_sdk, bvseo-3.1.1
  • CLOUD, getContent, 88ms
  • REVIEWS, PRODUCT