Q:Is this the correct lug to connect to a PK ground bar in a 200 amp Square D QO panel, for a 4 gau...
by|Mar 9, 2020
2 Answers
Answer This Question
A:Â Hello Bobby,
Consider using an LK100AN it will accept a #6 - 2/0 AWG AL or CU wire.
Regards,
Schneider Electric Customer Care.
by|Mar 11, 2020
A:Â Yes, technically it will work as it is rated to accept #4 gauge wire. However, if the #4 wire is stranded, it can be difficult to get the wire into the lug because the most of the time when stranded wire is cut it becomes sort of an oval shape, and the #4 wire has to be perfectly round to fit into the #4 rated lug. So if it is stranded wire I would recommend the larger lug that Schneider customer care recommended.
by|Apr 10, 2021
Q:i know this says 70 amp but will it work on 100 amp
by|Sep 25, 2016
2 Answers
Answer This Question
A:Â Yes. Not sure why they say 70 amp, as lugs are not rated by amperage but by the size wire they accept. It will physically fit in panels rated for more amps and as long as the wire you are terminating into the lug is within the lugs' range you are good to go. (If the wire is too large and stranded wire, no cutting some of the strands to make it fit into the lug. That is a code violation.)
by|Apr 10, 2021
A:Â Yes. The QO70AN is a 'Fork' type neutral lug that mounts in two of the wire binding holes in a branch neutral bar or PK ground bar and uses the wire binding screws for those holes tighten the lug in place.
by|Jul 23, 2019
2 found this answer helpful
Showing 1-2 of 2
Customer Reviews
4.9 out of 5
(6)
4.9
out of 6 reviews
100% recommend this product
5
5
4
1
3
0
2
0
1
0
Filter by:
Showing 1-6 of 6 reviews
Jan 15, 2021
Took 17 days to get them. I saw them in...
Took 17 days to get them. I saw them in two stores while waiting, but already paid for them.
by
Verified Purchase
Apr 21, 2020
Very easy to install in a Sq D Panel. I used it in a ITE panel and had to break off one of the le...
Very easy to install in a Sq D Panel. I used it in a ITE panel and had to break off one of the legs because the holes in the bar were too far apart. This should work in a fault.
by
Verified Purchase
Recommended
Dec 19, 2019
Was well designed and easy to install...
Was well designed and easy to install
by
Verified Purchase
Sep 18, 2019
5 Star Review
Rating provided by a verified purchaser
by
Verified Purchase
Aug 28, 2019
5 Star Review
Rating provided by a verified purchaser
by
Verified Purchase
Aug 26, 2014
Perfect adapter for large wire
I needed this lug kit to install a #2 gauge wire on the bus bar. Worked great!
For field installation, use this Square D by Schneider Electric Neutral Lug. It is compatible with aluminum or copper wire #6 - 2/0. It has both a UL listing and ANSI certification.
For field installation, use this Square D by Schneider Electric Breaker Box Neutral Lug. It is compatible with aluminum or copper wire #6 - 2/0. It has both a UL listing and ANSI certification.
Use this Homeline Breaker Box Neutral Lug with Homeline load centers that came before the S1 series. This kit helps eliminate the need for a separate generator panel. This lug accepts #14 - 4 copper wire and #10 - 2 aluminum wire.
This Homeline Circuit Breaker Retaining Kit retains a back-fed breaker when used to secure a circuit breaker to the interior of a load center. It is designed for use with HOM48L125GC, GRB and HOM612L100F/S, RB load centers. This retaining kit features a UL listing and ANSI certification to ensure safety.