Siemens Quadplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Quadplex Circuit Breakers provide overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Quad breakers provide two sets of common trip, 2-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.
Product Depth (in.) | 12.8 in |
|---|---|
Product Width (in.) | 3.5 in |
AIC Rating | 10 |
|---|---|
Amperage (A) | 20 A |
Breaker Type | Quadplex |
Connection Type | Non-Neutral |
Interruption Type | Standard Trip |
Mounting Type | Plug-On |
Number of Poles | Quad |
Number of Spaces | 0 |
Pack Size | 1 |
Product Weight (lb.) | 0.758 lb |
Returnable | 90-Day |
Series Type | QT |
Trip Unit | Thermal Magnetic |
Voltage (V) | 240 V |
Certifications and Listings | UL Listed |
|---|---|
Manufacturer Warranty | Lifetime |
If your label lists Murray MH-T type breakers then yes you can use the Siemens QT type breakers
Correct this unit has an inside 20 Amp double-pole and outside 20 Amp double-pole circuit breaker. https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Specification%20Sheet/SIE_BR_QT.pdf
Not without upgrading the wires to handle the extra amperage. Unless they are oversized already. Otherwise just call the fire department instead of flipping the breaker.
You would need to confirm with local electrician or our tech support 800-333-7421 they would need to know the application you are installing in as well
This would be something you could ask your local electrician or reach out to our Tech Support line at 800-333-7421 wiring installing, wiring and troubleshooting make sure you have the application it's being installed in ready when you reach out. https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Specification%20Sheet/SIE_BR_QT.pdf
Correct and requires 2-panel spaces https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Specification%20Sheet/SIE_BR_QT.pdf
If your Murray panel label lists MH-T breaker type then yes you can use the Siemens QT ~ Murray quad was MP23050CT2 current offering Q23025CT2 https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Specification%20Sheet/SIE_BR_QT.pdf
No the quadplex QT breakers are not UL listed for Arrow Hart load centers.
Depending on the voltage of the dryers you can reach out to our Tech Support line at 1-800-333-7421 to confirm https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Specification%20Sheet/SIE_BR_QT.pdf
Normally dryer circuit is 50 amp continuous. With 3 4awg aluminum or 3 8awg copper wire with separate 10 awg ground