Siemens SN Series Load Center is the smart choice when value and quick installation are of highest priority. The SN Series load centers include labor saving features such as the ability to accept Plug-on neutral breakers, patented Insta-wire and mounting trim tabs. These exclusive features make the SN Series load center the best load center for the value minded contractor.
Dimensions: H 24 in, W 14.25 in, D 3.88 in
Product Depth (in.) | 3.88 in |
|---|---|
Product Height (in.) | 24 in |
Product Width (in.) | 14.25 in |
Breaker Box Type | Subpanel |
|---|---|
Connection Type | Neutral |
Electrical Product Type | Main Lug/ Main Lug Kit |
Indoor/Outdoor | Indoor |
Maximum Amperage (A) | 150 A |
Mounting Type | Flush, Surface |
NEMA Configuration | NEMA 1 |
Number of Circuits | 40 |
Number of Spaces | 20 |
Product Weight (lb.) | 26.646 lb |
Returnable | 90-Day |
Series Type | SN |
Voltage (V) | 120/240 V |
Certifications and Listings | UL Listed |
|---|---|
Manufacturer Warranty | 10 Years |
Siemens does not offer a 30A dual function breaker, 20A max. The SN3048L1125 will accept QFGA2 frames (Q115DF,Q120DF) and QFP frames (Q230GF). Wiring diagram https://cache.industry.siemens.com/dl/files/338/109796338/att_1065059/v1/SIE_WD_LC_SN3048L1125.pdf
The SN series is not convertible to main breaker ~the only way you can convert this to main breaker would be to use a Q2100 breaker with ECMBR2 main breaker retaining clip .. which is backfed main .. max would be 100amps per wiring diagram https://dcc-data-extract.s3.us-east-1.amazonaws.com/new-delta/asset/Compas/daily/Compas/Wiring%20Diagram/SIE_WD_LC_SN2040L1125.pdf?103125
This unit cannot be converted to main breaker but you can back feed the Q230 using a breaker hold down kit ECMBR2 https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Wiring%20Diagram/SIE_WD_LC_SN1224L1125.pdf
See branch breaker types listed in wiring diagram link provided under branch breaker section https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Wiring%20Diagram/SIE_WD_LC_SN1224L1125.pdf
Correct https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Wiring%20Diagram/SIE_WD_LC_SN4040L1200.pdf
The load center will accept a maximum of 40 poles total, one inch space per pole. See the link to the spec sheet https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Specification%20Sheet/SIE_SS_LC_SN4040L1200-W.pdf
Yes
It means you cannot load the bus with more than 200 amps. Individual breakers inside the panel can add up to anything as long as the actual load does not exceed 200 amps. This should not be possible if the overcurrent protection device is sized properly.
200A maximum means the bus bar is rated for 200A https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Wiring%20Diagram/SIE_WD_LC_SN4040L1200.pdf