AI-generated from the text of manufacturer documentation. To verify or get additional information, please contact The Home Depot customer service.
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer 20/20 Amp 1 in. Duplex Type BR Circuit Breaker is also known as tandem breaker. Tandem breakers are convenient for adding circuits to a full load center and are sometimes used to reduce the physical size of the load center. This a non-circuit limiting breaker. The BR tandem line of breakers is intended for replacement purposes on load centers made prior to 1968.

Product Depth (in.) | 2.89 in |
|---|---|
Product Width (in.) | 0.98 in |
AIC Rating | 10000 |
|---|---|
Amperage (A) | 20 A |
Breaker Type | Tandem |
Connection Type | Neutral |
Interruption Type | Standard Trip |
Mounting Type | Plug-On |
Number of Poles | Double |
Number of Spaces | 1 |
Pack Size | 1 |
Product Weight (lb.) | 0.37 lb |
Returnable | 90-Day |
Series Type | BR |
Trip Unit | Thermal Magnetic |
Voltage (V) | 120/240 V |
Certifications and Listings | ANSI Certified, CSA Listed, UL Listed |
|---|---|
Manufacturer Warranty | 10 Years |
Hi, the wire range for this breaker is #14-4 AWG. This will accept a 12 gauge wire. If you have further questions, please contact our technical support team at 877-386-2273 opt 2 opt 3 opt 1.
Hi, NON-CTL means this breaker is not a circuit limiting breaker. This breaker will not have the rejection feature like the CTL (circuit limiting) breakers. If you have further questions, please contact our technical support team at 877-386-2273 opt 2 opt 3 opt 1.
Hi, this breaker will replace the Challenger A2020 breaker. If you have further questions, please call our technical support team at 877-386-2273 Opt. 2 Opt. 3 Opt. 1.
Hi, unfortunately you cannot replace this with a BR120 and connect two loads to it. The BR120 is rated to accept only one conductor per terminal. If you have further question, please contact our technical support team at 877-386-2273 opt 2 opt 3 opt 1.
Hi, the Eaton BR series breakers are not UL listed to be used in a Sylvania panel. However, the Eaton BR series breakers will physically fit in the Sylvania panel. If you have further questions, please call our technical support team at 877-386-2273 Opt. 2 Opt. 3 Opt. 1.
Hi, the single pole tandem breaker is designed to save space in the panel. It allows you to run two 120V circuits from a single breaker, while only occupying one slot in the panel. If you have further questions, please call our technical support team at 877-386-2273 Opt. 2 Opt. 3 Opt. 1.
Hi, the publication sticker on the panel should tell you what style breaker the panel is designed to accept. You could also look at the bus stab on the panel and see if it is a full stab (non-CTL) or a notched stab (CTL). If you have further questions, please call our technical support team at 877-386-2273 Opt. 2 Opt. 3 Opt. 1.
Hello, a Non-CTL breaker does not have rejection tabs and is compatible with BR and BRP loadcenters. If you need further assistance, please contact our technical support team at 877-386-2273, select options 2, 3, and 1, or email TRC@Eaton.com.