Brand | GE | GE | GE | GE |
Name | PowerMark Gold 100 Amp 20-Space 20-Circuit Indoor Main Breaker Circuit Breaker Panel | PowerMark Gold 100 Amp 20-Space 20-Circuit Outdoor Main Breaker Circuit Breaker Panel | PowerMark Gold 200 Amp 32-Space 40-Circuit Main Breaker Indoor Circuit Breaker Panel | PowerMark Gold 150 Amp 16-Space 32-Circuit Main Breaker Indoor Circuit Panel |
Price | ||||
Ratings | (87) | (69) | (87) | (87) |
Number of Spaces | 20 | 20 | 32 | 16 |
Indoor/Outdoor | Indoor | Outdoor | Indoor | Indoor |
Number of Circuits | 20 | 20 | 40 | 32 |
Load Center Type | Main Breaker | Main Breaker | Main Breaker | Main Breaker |
Maximum Amperage (amps) | 100 | 100 | 200 | 150 |
Electrical Product Type | Load Center | Load Center | Load Center | Load Center |
Load center width (in.) | 14.38 | 13 | 14.38 | 14.38 |
Load center height (in.) | 23.13 | 26.56 | 33.32 | 24.81 |
Mounting Type | Plug-On | Plug-On | Plug-On | |
View Product | View Product | View Product | View Product |
![]() | ![]() | ![]() | ![]() | |
Brand | GE | GE | GE | GE |
Name | PowerMark Gold 100 Amp 20-Space 20-Circuit Indoor Main Breaker Circuit Breaker Panel | PowerMark Gold 100 Amp 20-Space 20-Circuit Outdoor Main Breaker Circuit Breaker Panel | PowerMark Gold 200 Amp 32-Space 40-Circuit Main Breaker Indoor Circuit Breaker Panel | PowerMark Gold 150 Amp 16-Space 32-Circuit Main Breaker Indoor Circuit Panel |
Price | ||||
Ratings | (87) | (69) | (87) | (87) |
Number of Spaces | ||||
Indoor/Outdoor | ||||
Number of Circuits | ||||
Load Center Type | ||||
Maximum Amperage (amps) | ||||
Electrical Product Type | ||||
Load center width (in.) | ||||
Load center height (in.) | ||||
Mounting Type | ||||
View Product | View Product | View Product | View Product |
The answer is yes if you don't have a main breaker or "TLM" style. The load center for TLM models are rated up to the amperage for that particular load center so it doesn't matter about incoming voltage. If you have a main breaker it would not trip properly based on the amperage being supplied. If your intention is to add a 150 or 200A service at some point you could then convert the TLM style load center to a main breaker by using THQMV150DP or THQMV200DP. Thanks for the question.
If you use a generator interlock kit, you can. GE PowerMark Gold Load Center/Generator Interlock Kit https://www.homedepot.com/p/GE-PowerMark-Gold-Load-Center-Generator-Interlock-Kit-THQLLX1/100674082
Thank you for your questions. 1. The TM1210CCU is a 100 amp main breaker and not suitable for a 60 amp sub panel. I would suggest TLM1212CCUP. It is a main lug version of the same panel that can be supplied with 60 amps. 2. The TLM1212CCUP will accept THQP breakers 1/2” frame breakers if that is what you have. 3. The TLM1212CCUP would also provide up to 24 circuits if using the 1/2” frame THQP breakers.
Yes Dj you can. Just place 3 on the left side and 3 on the right side of the panel. That way you balance your load.
Hi PleaseHelp, thank you for your inquiry. Unfortunately we do not offer a replacement cover panel for this unit on Homedepot.com at this time. We appreciate your business and look forward to serving you in the future. Thank you for shopping Home Depot!
Thank you for your question. Yes, the THQL1120DFP can be installed in the TM4020CCUP load center.
Thank you for your question. The width of the enclosure box is 14 3/8" wide. The width of the cover is 15 3/8" wide.
Thank you for your question. A door lock for indoor load centers larger than 12 circuits is part number TDL106. This can be ordered via special order from any Home Depot store location.
I would need to know what panel model number you have outside and inside to try and answer the question. Thanks for the request.