PowerMark Gold 125 Amp 8-Space 16-Circuit Indoor Main Lug Circuit Breaker Panel

  • Indoor NEMA 1 enclosure
  • Main lugs are factory installed; convertible to main breaker
  • Use with equipment ground kit TGL2 (order separately)
  • See More Details

Frequently Bought Together

+
+
Price:

Product Overview

The load center includes a sturdy tin-plated copper buss bar and a galvanized box for increased durability and reliability. The one-piece interior removes and re-installs easily. Indoor NEMA 1 enclosure with surface mount cover. This load center is UL listed and ANSI Certified.
  • Maintenance-free, rust-resistant galvanized box
  • Copper buss bar for excellent conductivity
  • Convertible to a main breaker
  • All neutral holes are rated for 14 - 4 wire
  • Single-phase, 3-wire, 125 Amp, 120/240 VAC
  • Compatible with GE THQL, THQP, GFCI, AFCI and Dual Function circuit breakers
  • Includes a self-adjusting dead-front cover for surface or flush installations
  • Meets UL and ANSI safety requirements
  • Accepts GE standard, GFCI and AFCI circuit breakers, including 1/2 in. THQP
  • Meets UL and ANSI safety requirements
  • Includes a self-adjusting dead-front cover for surface or flush installations
  • Learn More About Electrical Panels Here in our Buying Guide.









  • Click here for more information on Electronic Recycling Programs

Info & Guides

You will need Adobe® Acrobat® Reader to view PDF documents. Download a free copy from the Adobe Web site.

Compare Similar Individual Subpanels

current product
PowerMark Gold 125 Amp 8-Space 16-Circuit Indoor Main Lug Circuit Breaker Panel
PowerMark Gold 125 Amp 14-Space 24-Circuit Indoor Main Lug Circuit Breaker PanelPowerMark Plus 125 Amp 8-Space 16-Circuit Indoor Main Lug Circuit Breaker PanelPowerMark Plus 125 Amp 8-Space 16-Circuit Outdoor Main Lug Circuit Breaker Panel
BrandGEGEGEGE
NamePowerMark Gold 125 Amp 8-Space 16-Circuit Indoor Main Lug Circuit Breaker PanelPowerMark Gold 125 Amp 14-Space 24-Circuit Indoor Main Lug Circuit Breaker PanelPowerMark Plus 125 Amp 8-Space 16-Circuit Indoor Main Lug Circuit Breaker PanelPowerMark Plus 125 Amp 8-Space 16-Circuit Outdoor Main Lug Circuit Breaker Panel
Price
Ratings
(117)
(117)
(38)
(96)
Maximum Amperage (amps)125125125125
Indoor/OutdoorIndoorIndoorIndoorOutdoor
Number of Spaces81488
Mounting TypePlug-OnPlug-OnPlug-OnPlug-On
Number of Circuits16241616
Load Center TypeMain LugMain LugMain LugMain Lug
Load center width (in.)11.562514.3811.3611.58
Load center height (in.)11.37516.1111.1111.11
View ProductView ProductView ProductView Product

Specifications

Dimensions

Load center depth (in.)
3.375
Load center height (in.)
11.375
Load center width (in.)
11.5625

Details

Electrical Product Type
Main Lug/ Main Lug Kit
Indoor/Outdoor
Indoor
Load Center Mounting Type
Flush,Surface
Load Center Type
Main Lug
Maximum Amperage (amps)
125
Mounting Type
Plug-On
Number of Circuits
16
Number of Spaces
8
Phase Type
1 Phase
Product Weight (lb.)
9
Returnable
90-Day
Voltage (volts)
240

Warranty / Certifications

Certifications and Listings
UL Listed
Manufacturer Warranty
One year warranty from first use

Questions & Answers

68Questions15Answers

Are these 1 hour fire rated?

Asked by Spark March 3, 2021
1
Answer

Thank you for your question. No, there is not a fire rating for load centers.

Box claims 8 circuit. For distributing 230 V it supports only 3 circuits. I was expecting 4 circ...

Asked by Katz February 8, 2021
0
Answers

I have a 100 amp main will this supply my new 125 amp lug box

Asked by Jj September 3, 2020
2
Answers

Yes when a main lug panel is rated for 125A it means you can use it to control from 0 up to 125A. Thanks for the question

What type of wire shlould i use to feed sub pannel from the main breaker

Asked by Charles August 21, 2020
0
Answers

16 spaces, 32 circuit, how do get to 32 circuits?

Asked by Sparky August 1, 2020
1
Answer

Hi Sparky, you would just select the 32 circuit option. It is currently in stock.We appreciate your business and look forward to serving you in the future. Thank you for shopping Home Depot!

Can I use double pole breakers in this box? Also will heavier gauge wire such as 6 gauge fit in t...

Asked by TIMT April 16, 2020
4
Answers

yes you can use 2 pole breakers. and the neutral and grounding bars do take 6 gauge wire stranded or solid

What grounding wire do I need for this panel

Asked by Chris November 19, 2019
1
Answer

It depends on the wire and breaker you're feeding the panel with and there is an nec table to go off of

Main lugs are factory installed; convertible to main breaker. What does this mean if you can't in...

Asked by Art October 27, 2019
2
Answers

You can use this panel as a sub and feed with the main lugs from a breaker in the main panel. If using this one as a main it'll need a 2 pole breaker and a main breaker hold down kit.

Will this fit in the walls for a trailer?

Asked by Daniel October 27, 2019
2
Answers

It is designed for a standard stud wall on 16” centers.

How to install a main breaker

Asked by Mdpalma44 October 14, 2019
2
Answers

Hi, This should be powered by a 2 pole breaker from a main panel somewhere else. Is this being powered right from your utility company??

PowerMark Gold 125 Amp 8-Space 16-Circuit Indoor Main Lug Circuit Breaker Panel - page 2

Customer Reviews

  • 4.4
    out of 118 reviews
  • 80% recommend this product
Filter by:
Showing 1-10 of 118 reviews
Good price and value
Good price and value
by RAMON
2 people found this helpful
Because the price was so affordable, I was able to overlook a couple of things: The screw holes ...
Because the price was so affordable, I was able to overlook a couple of things: The screw holes in the cover didn't align with the ones in the box. I had to do a bit of "hammer adjustment"! Also the bus contact didn't quite line up with one the breakers, so a little more "alignment" required. The knock-outs in the box required more than a little "knocking" to get them out, but like I said, I didn't pay a lot for it and after adding a ground buss, it did the job I wanted, a small sub-panel in my garage to support a welder, for not a lot of cash outlay! On the plus side, the breakers aligned well with the cover opening and the finish is good. I was able to install two (2) single breakers (120VAC) for my lights and receptacles and a double breaker (240VAC) for the welder and compressor. It fit in the same small footprint of the previous box. If you are on a budget, and don't mind a bit of "adjusting", I recommend this box as a small, low priced alternative. Once it's mounted and working, you'll be glad you did!
by MustangMan
1 person found this helpful
Spacious panel.
Spacious panel.
by GLENFORD
1 person found this helpful
Pictured style discontinued
The TLM1212CCU has undergone a design revision in which it has 1/2" knockouts, and no main breaker knockout up top (and is notably smaller). I, too, went to purchase one to match my existing subpanel and found the item pictured is not what is sold in stores (nor is it at the blue box competitor). Based on GE's current catalog, if you're looking for what is pictured above, you will need to seek a TM1212CCU (note the absence of the "L")... Or find old stock somewhere. Boxes with red amperage labels are the newer revisions (which don't match the picture, and usually have a "P" at the end of the model number).
by Hugh
11 people found this helpful
For replacing a FPC panel, this is the only Panel...
For replacing a FPC panel, this is the only Panel fit the old one's size.
by customer
Great value for the price...
Great value for the price
by George
Great price. I used it as a sub panel.
Great price. I used it as a sub panel.
by Sparks
Rating provided by a verified purchaser...
Rating provided by a verified purchaser
by HomeDepotCustomer
Very strong enclosure with a good selection of knockouts and...
Very strong enclosure with a good selection of knockouts and holes for component mounting. Circuit breakers were slightly difficult to snap in but a strong seating is important. Wire lugs are thick and hold wires securely.
by JIM
The box replaced an older circuit in a garage and...
The box replaced an older circuit in a garage and worked great for my needs. Easy installation and works as intended.
by Raven
Showing 1-10 of 118 reviews