The HOME-FLEX Underground 1 1/2 in. anodeless meter riser allows to safely and easily transition from polyethylene pipe to a gas meter. Male iron pipe (MIP) threads on the metal side for direct connection to the meter. Durable metal construction ensures no damage will occur to pipe above the surface.
Double Fitting Size | 1-1/2" x 1-1/2" |
|---|---|
Fitting 1 size | 1-1/2" |
Fitting 2 size | 1-1/2" |
Fitting Size Dimensions | 1-1/2" x 1-1/2" |
Product Length (in.) | 30 in |
Single Fitting Size | 1-1/2" |
Application | Natural Gas, Propane |
|---|---|
Color Family | Gray |
Compatible Pipe Material | Polyethylene |
Connection | MPT x Plain End |
Connection 1 | MPT |
Connection 2 | Plain End |
Connectivity | Threaded |
Features | Threaded, Underground Rated, Underground Use |
Fitting or Connector Type | Adapter |
Fitting/ Connector Collection | Polyethylene |
Material | Polyethylene |
Maximum working pressure (psi) | 90 |
Maximum Working Temperature (F) | 140 |
Pack Size | 1 |
Pipe or Fitting Product Type | Pipe & Tubing |
Product Weight (lb.) | 7 lb |
Returnable | 90-Day |
Manufacturer Warranty | 1 year |
|---|
The underground end is PE gas pipe, so you will need the matching IPS PE gas coupling to connect it to your roll of poly pipe. The above ground end has male NPT threads for a shutoff valve or transition fitting to black iron pipe or CSST.
No. The risers are epoxy coated carbon steel.
The riser is an Anode-less Riser so does not need to have a dielectric union when attaching to stainless steel or black iron etc. The steel is a mild steel (low carbon).
There is not an issue with galvanic corrosion when attaching black iron/stainless steel to the metal threaded section of the Riser – Installation should Teflon tape or pipe thread sealant on the threads.
1. This 2-inch riser can be reduced to 3/4-inch by using a 2-inch to 3/4-inch reducer fitting. Ensure the reducer fitting is compatible with the materials of the riser and the pipe you are connecting to. 2. Galvanic corrosion occurs when two dissimilar metals are in contact in the presence of an electrolyte (like water). Stainless steel connectors are generally preferred over galvanized steel when connecting to a riser to minimize the risk of galvanic corrosion. Using Teflon tape or pipe thread sealant on the threads can also help prevent corrosion. However, there should not be a significant issue with galvanic corrosion when connecting this specific riser to either galvanized steel or stainless steel, as the threaded portion of the riser is designed to be compatible with various types of metallic pipe.