#1 Home Improvement Retailer

Internet # 306235827

Model # 18-401-012

Store SKU # 1003416902

Store SO SKU #1003416902

1-1/4 in. IPS DR 11 Underground Yellow Poly Gas Pipe Tee

$64.16
Apply Now
Pay $39.16 after $25 OFF your total qualifying purchase upon opening a new card. info
Apply for a Home Depot Consumer Card
  • For use with Natural Gas and Liquid Propane applications
  • Only compatible with IPS sized, polyethylene pipe
  • The only underground gas compression fitting on the market
  • View More Details
Store
0 in stock
icon
Free & Easy Returns In Store or Online
Return this item within 90 days of purchase. Read Return Policy

Product Details

Home Flex Underground Fitting - Expanded View

Revolutionary Compression Design

The unique compression design makes it the easiest underground gas fitting on the market. No special tools or skills required.

Home Flex Underground Lifestyle

Easy Install Of Underground Gas Lines

With HOME-FLEX UNDERGROUND, just cut your pipe and insert the included stiffener. There’s no need to chamfer the pipe, only smooth away any burrs and then tighten the nuts.

HOME-FLEX Underground Coupler

Connect Pipe With Ease

Easily connect runs of pipe to another pipe run, a meter riser, or transition fitting with our one-of-a-kind fittings.

HOME-FLEX Underground Elbow

Make 90 Degree Turns Without Special Tools

It is simple to change the direction of your pipe run with our different fitting options.

HOME-FLEX Underground Tee

Easily Add To Your Pipe System

With the ability to remove and reuse the fittings again and again, you can add a tee and make a new line whenever you want.

HOME-FLEX Underground Pipe

Lightweight, Durable, And Never Rusts

This MDPE pipe is easier to use than standard steel pipe, and the polyethylene construction will never rust.

Easy Installation

Simple Installation

Easy to follow steps and a simple compression design makes install a breeze.

Quick Installation

Save Time And Money

Quickly install yourself with no need to purchase professional tools or services.

Reuseable

Reuse The Same Supplies

When changing the location or adding to a line, just remove and reinstall.

Rated for 125 PSI

Exceeds PSI Standards

Use with confidence knowing the products are made to withstand high PSI ratings.

IPS Sized

Iron Pipe Size Measurements

All pipe and fittings are IPS (Iron Pipe Size) and are fully compatible with other IPS polyethylene pipe.

Direct Burial

Direct Burial Permitted

These gas pipe and fittings are approved for underground application.

About This Product

The HOME-FLEX Underground Tee allows for safely and easily expanding your underground gas system. Simply cut the pipe, slide in the provided stiffener and slide into the fitting. Then tighten with standard channel locks or pliers.

Highlights

Product Information

Internet # 306235827

Model # 18-401-012

Store SKU # 1003416902

Store SO SKU #1003416902

Specifications

Dimensions

Double Fitting Size

1-1/4" x 1-1/4"

Fitting 1 size

1-1/4"

Fitting 2 size

1-1/4"

Fitting 3 size

1-1/4"

Fitting Size Dimensions

1-1/4" x 1-1/4" x 1-1/4"

Product Height (in.)

5 in

Product Width (in.)

3.23 in

Single Fitting Size

1-1/4"

Triple Fitting Size

1-1/4" x 1-1/4" x 1-1/4"

Details

Application

Natural Gas, Propane

Color Family

Yellow

Color/Finish

Yellow

Compatible Pipe Material

Polyethylene

Connection 1

Comp

Connection 2

Comp

Connection 3

Comp

Connectivity

Compression

Features

Underground Rated, Underground Use

Fitting or Connector Type

Tee

Fitting/ Connector Collection

Polyethylene

Material

Polypropylene

Maximum working pressure (psi)

125

Maximum Working Temperature (F)

140

Pack Size

1

Pipe or Fitting Product Type

Fittings & Connectors

Product Weight (lb.)

1.46 lb

Reducing Fitting

No

Returnable

90-Day

Warranty / Certifications

Manufacturer Warranty

1 year

Questions & Answers

10Questions
caret
Q:Can you disconnect and re-connect the same fitting?
by|Nov 16, 2023
0 Answer
Answer This Question
caret
Q:Can IPS DR 11 be used in a crawl space under my home without burying it?
by|Jun 18, 2022
4 Answers
Answer This Question

A:  I would not imagine this method of use is up to any building code, but I see no reason why it would not *work*

by|Jun 25, 2022

    A:  Hi, Eddie. No. Underground PE pipe and components should NEVER be used in a home or under a foundation with a structure on it. Please IGNORE "community answers" indicating otherwise.

    by|Jun 20, 2024
      1 found this answer helpful

      A:  The Home-Flex installation manual specifies that the product is NOT to be installed inside or under a building. It's intended for direct burial.

      by|Jun 20, 2024
        1 found this answer helpful

        A:  I used this pipe for a propane line. Propane is heavier than air, so I would suspect that any leak in a low enclosed area could potentially be dangerous. I myself would not use these connectors in any area that could allow the accumulation of gas.

        by|Jun 20, 2024
          2 found this answer helpful
          caret
          Q:How do I go from a 1 1/2" main line and tee off to 3/4" pipe?
          by|Oct 17, 2021
          1 Answer
          Answer This Question

          A:  Hi Stella, if you could give me a call, I can tell you more about how to go about this. (661) 257-3923 Ext 1010. My Name is Jon. I am here M-F from 8-5 Los Angeles time.

          by|Oct 18, 2021
            caret
            Q:Do you make a pipe tee that will work with Home FLex 3/4 in. CSST x 25 ft. Corrugated Stainless Steel Tubing? I assume this will not work with that pipe.
            by|Apr 23, 2020
            1 Answer
            Answer This Question

            A:  No. HOME-FLEX Underground Fittings are for use on yellow poly gas pipe. These fittings are not approved for use on any other material. For our CSST we use iron Tees when needed. Fit a HOME-FLEX CSST pipe thread adapter to an iron Tee o your choice. Then connect each segment of CSST. For more info, give us a call. 661-257-3923. We are here from 8-5 Los Angeles time M-F. Ask for Jon.

            by|Jun 20, 2024
              1 found this answer helpful
              Showing 1-4 of 10

              Customer Reviews

              4.7 out of 5

              • 4.7 out of 103 reviews
              • 100% recommend this product
              Filter by:
              Showing 1-10 of 103 reviews
              Ran 300' of Home Flex gas line using the supplied fittings for my home generator. This is second ...
              Ran 300' of Home Flex gas line using the supplied fittings for my home generator. This is second time using this product totaling over 500' used. The fittings are super easy easy to use and the gas line is effortless to install.
              by
              • Verified Purchase
              • Recommended
              • Verified Purchase
              Returned all of it. Copper is cheaper!
              by
              • Verified Purchase
              Very straight forward and easy to use
              by
              • Verified Purchase
              by
              • Verified Purchase
              • Verified Purchase
              • Verified Purchase
              perfect fit for the job
              by
              • Verified Purchase
                • Verified Purchase
                Showing 1-10 of 103 reviews

                Compare Similar Items

                current item

                Fitting 1 size

                1-1/4"

                2"

                1"

                1-1/4"

                Fitting or Connector Type

                Tee

                Coupling

                Adapter

                Adapter

                Connectivity

                Compression

                Compression

                Threaded

                Threaded

                Application

                Natural Gas, Propane

                Natural Gas, Propane

                Natural Gas, Propane

                Natural Gas, Propane

                Features

                Underground Rated, Underground Use

                Underground Rated

                Underground Rated, Underground Use

                Threaded, Underground Rated, Underground Use