Siemens introduces new Tandem Combination Type Arc Fault Circuit Interrupters (CAFCI), expanding the capabilities of the CAFCI, designed to allow 1 breaker to feed 2 circuits - saving on both space in the load center and installation time, while keeping safety and compliance top of mind. Siemens Tandem AFCI breakers are the perfect solution to wiring made easier, allowing for smaller load center needs due to the combined position use. Trusted lug wire indicator flags are installed to show when load wires are correctly inserted into the lugs. Siemens CAFCI breakers are ideal for new construction and renovations, available in either Plug-On Neutral or Pigtail versions. Siemens Tandem AFCI breakers are National Electrical Code (NEC) 210.12 compliant.
Product Depth (in.) | 1.3 in |
|---|---|
Product Width (in.) | 6.0 in |
AIC Rating | 10 |
|---|---|
Amperage (A) | 20 A |
Breaker Type | Tandem |
Connection Type | Neutral |
Interruption Type | AFCI |
Mounting Type | Plug-On |
Number of Poles | Single |
Number of Spaces | 0 |
Pack Size | 1 |
Product Weight (lb.) | 0.55 lb |
Returnable | 90-Day |
Series Type | Not Specified |
Trip Unit | Electronic |
Voltage (V) | 120 V |
Certifications and Listings | UL Listed |
|---|---|
Manufacturer Warranty | Standard |
We would need to know what panel you have before advising. You may send an email with this information to productselection.us@siemens.com for them to advise.
The only difference is the Q2020AFCNP (P) ending means it comes in special retail packaging and the Q2020AFCN comes in standard packaging
Q2020AFC is the QTA tandem AFCI combo breaker, Q2020AFCNP is the plug on neutral tandem AFCI combo breaker. Plug on neutral breakers can only be used in panels that are listed on the wiring diagram that they can accept plug on neutral breakers. The Siemens load center will list which breakers are compatible with the specific load center. Always refer to wiring diagram of said load center.
Yes as that is what they were designed for. SN and PN panels have plug-in-neutral bars that this breaker requires.
If your panel lists breaker types QAF and QAF2 or QAF2N then yes you can use QTAN type breakers.
No the Q2020AFCN is for our Plug On Neutral Load Center line only you would need the Q2020AFC type with pigtail https://s3.amazonaws.com/dcc-data-extract/new-delta/asset/Compas/daily/Compas/Specification%20Sheet/SIE_SS_TandemCAFCI.pdf
Siemens breakers are not listed for use in other manufacturers equipment. You would need to contact Eaton to determine if they have approved this Siemens breaker for use in their equipment.
They are the exact same except for the Q2020AFCNP ending in "P" has special retail packaging for our retail accounts.